Transcription of Kii - Applied Medical
1 Kii Access Systems12mmAccess SystemInsufflationNeedle3mm5mmAccess SystemKii FiosFirst EntryMinimal Penetration with Rapid InsufflationOnly 3mm of trocar penetration to initiate insufflationTrue Non-Bladed Access with Minimal Fascial Defect Allows for reapproximation of tissue layers upon removalKii Fios First Entry SystemTHE ONLY INSUFFLATING OPTICAL PORTNow available in a 5mm the smallest hasson available!Suture TiesMaximizes instrument reach and facilitates port site closureGel ConeEnhances instrument articulationNon-Latex BalloonProvides stable anchoring throughout lengthy procedures while maximizing working space and visibilityOptical Blunt Tip ObturatorFacilitates direct visualization during trocar placementKii Balloon Blunt Tip SystemINNOVATIVE BLUNT TIP TECHNOLOGYNon-Latex BalloonProvides unmatched retentionMaximizes working space and visibilityProvides pressure on incision site, potentially reducing port-site bleedingMaintains stability throughout proceduresRetention DiskReduces migration of the trocar sleeve into the abdominal cavityKii Advanced Fixation SleeveSUPERIOR RETENTIONLow Profile Seal HousingOptimizes external working space, minimizing interference with adjacent portsZ-thread Sleeve with Extended ThreadsMaintains retention at shorter depths.
2 Maximizing internal working space and visibilityLow Profile Kii SealStandard 5mm Kii SealKii Low Profile SystemSLIM, LIGHTWEIGHT DESIGNI ntuitive Switch DesignProvides clear indication of shield positionDeactivatedActivatedKii Shielded Bladed SystemReorder FixationZ-threadCFB03 CTB035 x 100mmN/AC0Q618 x 100mmCFB33 CTB3311 x 100mmCFB73 CTB7312 x 100mmKii Shielded Bladed SystemSMOOTH, CONTROLLED ENTRYKii Optical Access SystemReorder FixationZ-threadCFR03 CTR035 x 100mmCFR01 CTR015 x 150mmN/AC0Q198 x 100mmCFR33 CTR3311 x 100mmCFR31 CTR3111 x 150mmCFR73 CTR7312 x 100mmCFR71 CTR7112 x 150mmN/AC0R3715 x 100mmN/AC0R3915 x 150mmTissue ReapproximationInitial WithdrawalMidwayComplete WithdrawalKii Optical Access SystemUNPARALLELED OPTICAL CLARITYV isit for more information 2017 Applied Medical Resources Corporation. All rights reserved. Applied Medical , the Applied Medical logo design and marks designated with a are trademarks of Applied Medical Resources Corporation, registered in one or more of the following countries: Australia, Canada, Japan, the United States and/or the European Union.
3 SC01738 EKii Advanced Fixation SleevesReorder No. SizeCFS035 x 75mmCFS025 x 100mmCFS015 x 150mmCFS1211 x 100mmCFS1111 x 150mmCFS2212 x 100mmKii Balloon Blunt Tip SystemReorder No. SizeC0Q205 x 100mmC0R4712 x 100mmC0R5012 x 130mmKii Low Profile SystemReorder x 55mmCTR22 CTB22 CTS295 x 100mmCTR23 CTB23N/A5 x 55mm, dual packCTR24 CTB24N/A5 x 100mm, dual packKii Fios First Entry SystemReorder FixationZ-threadCFF05N/A5 x 75mmCFF03 CTF035 x 100mmCFF01 CTF015 x 150mmCFF33 CTF3311 x 100mmCFF31 CTF3111 x 150mmCFF73 CTF7312 x 100mmCFF71 CTF7112 x 150mm