Laboratory Ventilation Systems Fume Hood Exhaust Blowers HEPA & Carbon Filtration Ducting & Exhaust Fume Scrubbers Manifolds HEMCO R. ISO 9001-2008 Certi ed Company Fume Hood Ducting and Exhaust system Ductwork connected to fume hoods may be arranged in a how different hood exhaust fumes will react when mixed in the variety of patterns depending on requirements. Generally, ductwork. Rigid PVC ductwork is recognized as an excellent the best exhaust system involves the shortest duct length fume hood exhaust duct material. The smooth interior surface and the fewest elbows. Duct size, length, and number of reduces static pressure loss and chemical waste build up, and elbows affect static pressure loss and blower efficiency.

Laboratory Ventilation Systems Fume Hood Exhaust Blowers HEPA & Carbon Filtration Ducting & Exhaust Fume Scrubbers Manifolds ISO 9001-2008 Certifi ed Company

Tags:

  System, Laboratory, Ventilation, Laboratory ventilation systems

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Laboratory Ventilation Systems - HEMCO Corporation

1 Laboratory Ventilation Systems Fume Hood Exhaust Blowers HEPA & Carbon Filtration Ducting & Exhaust Fume Scrubbers Manifolds HEMCO R. ISO 9001-2008 Certi ed Company Fume Hood Ducting and Exhaust system Ductwork connected to fume hoods may be arranged in a how different hood exhaust fumes will react when mixed in the variety of patterns depending on requirements. Generally, ductwork. Rigid PVC ductwork is recognized as an excellent the best exhaust system involves the shortest duct length fume hood exhaust duct material. The smooth interior surface and the fewest elbows. Duct size, length, and number of reduces static pressure loss and chemical waste build up, and elbows affect static pressure loss and blower efficiency.

2 PVC is extremely resistant to a wide variety of reagents. For Ideally, each fume hood should have its own ducting and some applications flexible PVC lined duct provides adequate blower to maximize hood flexibility and reduce danger of service and can significantly reduce installation costs. When backdraft from other hoods. planning exhaust ducting, duct size, length, number of bends, and exhaust material must be considered. Common or manifold ductwork designs can be used, Fume hoods exhaust large quantities of Laboratory air, and to provided duct and blower have been sized properly.

3 In work properly a similar quantity of fresh air must be supplied these designs, individual hood dampers are recommended to the room. to balance the system . Hood users must be aware of Passive Auto Sash Management VAV Air Flow Control Valve Cut energy costs, for improved lab efficiency Electronically controlled actuating Weather Cap Maintains the proper amount of room air changes dampers controls airflow to maintain #12-Page 3. per hour in the lab. desired face velocity. Includes controller, alarm, transformer, Energy saving green product night set back, and airflow display.

4 UniFlow fume hood air Visit: for details Rain Skirt by-pass constant air volume Exhaust Blower #10-Page 3. and, variable air volume See page 4-5. Cat. No. 51401. models designed for energy savings and user protection. Cat. No. 51501. Roof Coupling #3-Page 3 Reducer VAV Air Flow 90o Elbow 45o WYE Control Valve #4-Page 3. #15-Page 3. #6-Page 3. 90o Elbow #4-Page 3. 45o Elbow Blast Gate Damper Butterfly Damper #5-Page 3 #9-Page 3 Diagram shows a manifold #8-Page 3. system consisting of 2 fume hoods & a single exhaust. Air ow Monitor Note: OSHA recommends Air ow Monitors to ensure user protection.

5 Continuously monitors face velocity airflow of fume hood. Select and calibrate at desired fpm velocity set point. If the Airflow hood face velocity falls below set Monitor point, an audible alarm sounds and a visual red indicator light appears. Airflow alarm is factory installed or can be field installed. 115V/60Hz AC. Cat. No. 51406. Air ow Monitor with Digital Display Continuously monitors face velocity airflow of fume hood. A. digital display of face velocity in m/sec or fpm that indicates safety reading with an audible alarm. Push button calibration Floor and 3 programmable input/.

6 Output relays. Factory installed or can be field installed. Cat. No. 51410. 2. Fume Hood Ductwork & Venting Accessories Ducting and accessories are chemical resistant and easy to install. Flexible and Rigid PVC Ducting 4 6 8 10 12 14 . 1. Flexible Ducting neoprene impregnated Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. fiberglass reinforced with steel helix wire. Stan- 80051 80052 80053 80054 80055 80056. dard 12' lengths. Each piece includes 2 clamps. 2. PVC Rigid Ducting chemical resistant for Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. permanent installations.

7 Standard 10' lengths 82004 82006 82009 82011 82013 82015. with straight ends. 3. PVC Coupling required to connect straight Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. sections. 82147 82149 82153 82157 82159. 82160. 4. PVC 90o Elbow used in order to offset ob- stacles. Has belled ends for duct connections. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. 82060 82061 82063 82066 82068 82069. 5. PVC 45o Elbow used in order to offset obsta- Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. cles. Less static pressure loss than a 90o elbow. 82082 82083 82085 82087 82089 82090.

8 Has belled ends for duct connections. 6. PVC 45o WYE lateral for joining common duc- twork in multiple hood designs. Branch diameter Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. may be sized to 2 to 4 smaller than main diam- 82216 82218 82226 82229 82233 82234. eter. Has belled ends for duct connections. 7. PVC Tee used in manifold exhaust Systems . Has belled ends for duct connection. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. 82034 82036 82038 82040 82044 82046. 8. PVC Butter y Damper modifies cfm for single or multiple hood arrangement. Cat. No. Cat. No.

9 Cat. No. Cat. No. Cat. No. Cat. No. Has belled ends for duct connection. 82450 82452 82454 82456 82458 82460. 9. PVC Blast Gate Damper a gate that slides in and out to control cfm. Has belled ends for duct Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. 82369 82371 82373 82375 82377 82379. connection. 10. PVC Rain Skirt slips over straight pipe on Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. roof to slope water away from cutout. 82328 82330 82332 82334 82336 82337. 11. PVC Vent Outlet for horizontal venting through wall or window. Angled end prevents Cat. No.

10 Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. 80074 80076 80077 80078 80079 80080. rain from entering. Male connector included. 12. Zero Pressure Weather Cap discharges fumes vertically away from roof. Self-draining. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Minimal static pressure loss. This is the 82350 82352 82354 82356 82358 82359. recommended weather cap. Condensation Ring Wash Ring Reducers Dia A Dia B Cat. No. 6 4 82613. Collects condensed Suited for use in perchloric 8 6 82615. vapors in ducting and A B. acid duct Systems . Features channels them to a 10 8 82617.