LED DriverLCA PRE, LC EXCP roduct ManualProduct Manual lca pre / lc exc | 08-2018 | | enTable of contentsc2 / 721. Validity Copyright .. Imprint .. 42. General safety instructions Intended use .. Dangers associated with the operation of the system .. Environment .. Additional instructions .. 63. Description and key features Description of key features .. Two-part layer structure .. Housing variants .. Adjustable output current, voltage and power .. Operating Window Multichannel .. 154. Compatibility between LED module and LED Driver Comparison of data sheet values with a 4-point guideline .. Application of the 4-point guideline .. Practical tests .. 325. Installation notes Safety information .. Function of the earth terminal.

Product manual LCA PRE / LC EXC | 08-2018 | 2.7 | en General safety instructions c 5 / 72 The instructions in this section have been compiled to ensure that operators and users of LED Driver LCA PRE and LC EXC from

Tags:

  Manual, Product, Lca pre, Lc exc product manual, Product manual lca pre, Lc exc

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of LED Driver LCA PRE, LC EXC Product Manual

1 LED DriverLCA PRE, LC EXCP roduct ManualProduct Manual lca pre / lc exc | 08-2018 | | enTable of contentsc2 / 721. Validity Copyright .. Imprint .. 42. General safety instructions Intended use .. Dangers associated with the operation of the system .. Environment .. Additional instructions .. 63. Description and key features Description of key features .. Two-part layer structure .. Housing variants .. Adjustable output current, voltage and power .. Operating Window Multichannel .. 154. Compatibility between LED module and LED Driver Comparison of data sheet values with a 4-point guideline .. Application of the 4-point guideline .. Practical tests .. 325. Installation notes Safety information .. Function of the earth terminal.

2 Routing the wires .. External fuse for DC operation .. Maximum loading of circuit breakers .. 386. Functions corridorFUNCTION V2 (PRE only) .. DSI (PRE only) .. switchDIM (PRE only) .. Power-up Fading (PRE only) .. DALI (PRE only) .. ready2mains .. Constant Light Output (PRE only) .. DC recognition .. Dimming on DC (PRE only) .. Intelligent Temperature Guard .. colourSWITCH .. 62 Product Manual lca pre / lc exc | 08-2018 | | enTable of contentsc3 / proportionSWITCH .. 1-10 V Interface .. 717. Reference list Additional information .. Downloads .. Technical data .. 72 Product Manual lca pre / lc exc | 08-2018 | | enScope of documentationc4 / 72 These operating instructions are valid for LED Driver of the lca pre and lc exc series.

3 Not included are lc exc Driver with widevoltage input range und LC OTD a reference is made to one of the two versions then the descriptions are valid only for that series comprises additional versions. However, the other versions ADV, SNC, ECO, TOP, TEC are not covered in detail within GmbH & Co KG is constantly striving to develop all its products. This means that there may be changes in form, equipmentand cannot therefore be made on the basis of information, diagrams or descriptions in these latest version of these operating instructions is available on our home page CopyrightThis documentation may not be changed, expanded, copied or passed to third parties without the prior written agreement ofTRIDONIC GmbH & Co are always open to comments, corrections and requests.

4 Please send them to ImprintTridonic GmbH & Co KGF rbergasse 156851 DornbirnAustriaT +43 5572 395-0F +43 5572 Manual lca pre / lc exc | 08-2018 | | enGeneral safety instructionsc5 / 72 The instructions in this section have been compiled to ensure that operators and users of LED Driver lca pre and lc exc fromTridonic are able to detect potential risks in good time and take the necessary preventative operator must ensure that all users fully understand these instructions and adhere to them. This device may only be installed andconfigured by suitably qualified Intended Proper useOperation of LED light modules. The device may only be used for this intended Improper useOutdoor use. Extensions and modifications to the Dangers associated with the operation of the Environment WARNING!

5 Improper use could result in injury, malfunction or damage to must be ensured that the operator informs every user of existing hazards. DANGER!Danger of electrocutionDisconnect the power to the entire lighting system before working on the lighting system! DANGER!Not to be used in corrosive or explosive environments. CAUTION!Risk of damage caused by humidity and condensationOnly use the control device in dry rooms and protect it against humidity!_Prior to commissioning the system, wait until the control device is at room temperature and completely dry!_Product Manual lca pre / lc exc | 08-2018 | | enGeneral safety instructionsc6 / Additional CAUTION!Electromagnetic compatibility (EMC)Although the device meets the stringent requirements of the appropriate directives and standards on electromagneticcompatibility, it could potentially interfere with other devices under certain circumstances!

6 Product Manual lca pre / lc exc | 08-2018 | | enDescription and key featuresc7 / Description of key featuresLCA PRE and lc exc is a portfolio of LED Drivers. It has been optimised and simplified to meet the typical requirements of requirements: The layers PRE and EXC offer solutions for different requirements ( dimming/fixed output, lifetime, applications)_State-of-the-art dimming technology:Stepless dimming from 100 to 1 % (PRE) and 100 to >=15 % (EXC) (see ).Two-part layer structure, p. 8_Broad range of casing shapes: Different casing shapes (compact, stretched compact, independent, low profile) and sizes for different built-in versions_Adjustable output current: Simple option for setting current and voltage values transition-free (PRE and EXC) allows the device to be used with virtuallyall light modules_Diversity of functions: Familiar and new functions, DALI, DSI, switchDIM, corridorFUNCTION (PRE only), dimming, ready2mains (PRE and EXC)_Tunable White:DT8: Dimming range: 3 - 100 %, colour temperature: 2,700 - 6,500 K, colourSWITCH2xCH / 4xCH DT 6: Dimming range.

7 1 - 100 %, proportionSWITCH_Product Manual lca pre / lc exc | 08-2018 | | enDescription of key featuresc8 / Two-part layer structureThe layers lca pre and lc exc differ as DimmingPortfolioPREEXCD immableDimmingmethodAmplitude dimmingAmplitude dimmingDimmingrange100 to 1 %100 to 3 % at TW DT8100 to >= 15 %DimmingcurveLogarithmic dimming curve (standard)Switching to linear dimming curve viamasterCONFIGURATOR is dimming curve (standard)DimminginterfaceDALI-2 DT6, DSI, ready2mains,corridorFUNCTION V2, switchDIMready2mains, 1-10 Vready2mainsINOTICEThe minimum achievable value depends on the used device andthe certain combinations of LED Driver and LEDmodule, the minimum value may be higher_When operating with lower load, the minimum value isgenerally higher_More information can be found in the data sheet of the is not available for TW DT8 and 2xCH / 4xCH DT 6 Manual lca pre / lc exc | 08-2018 | | enDescription of key featuresc9 / FunctionsPortfolioPREEXCC onstant Light Output Intelligent Temperature GuardPower-up Fading DC OperationDC level adjustablesupporting EN 50172 DC level fixed supporting EN 50172 Constant Light Output Output currentPortfolioPREEXCA djustableoutput currentAdjustable DT6, ready2mains, I-select 2 plug (resistor)ready2mains, I-select 2 plug (resistor)Step size1 mA1 mAToleranceFurther information can be found in the data sheet (see).

8 Reference list, p. 72 Further information can be found in the data sheet (see).Reference list, p. 72 INOTICE ready2mains is not included in TW DT8 and 2xCH / 4xCH DT White has device type DALI DT 8 INOTICEBy using I-Select Plugs, all channels on the TW DT8 and 2xCH / 4xCH DT 6 will be set to the same Manual lca pre / lc exc | 08-2018 | | enDescription of key featuresc10 / Technical dataPortfolioPREEXCR ated supply voltage220-240 V220-240 VStandby losses< W .. Product Manual lca pre / lc exc | 08-2018 | | enDescription of key featuresc11 / 72 Housing variantsAll the layers are available in three different housing variants: compact, independent and low variant compactHousing variant stretched compactHousing variant independentHousing variant low profileCompact shape for installation inside the luminaire casing (in-built)_Typical area of application: Spotlights, downlights_Shape that can be used as compact or independent (for an installation outside theluminaire strain relief can be attached to the casing)_Typical area of application: Spotlight, downlight_Long and small shape for installation outside the luminaire casing (remote)_Typical area of application.

9 Spotlights, Downlights_Special characteristic: Full loop-through capability of mains and interface (DALI)cables_Flat shape for a space-saving installation inside the luminaire casing (in-built)_Typical area of application: area lighting, linear lighting_Product Manual lca pre / lc exc | 08-2018 | | enDescription of key featuresc12 / Adjustable output current, voltage and powerLCA PRE and lc exc allow for different combinations of power and current based on the standard lumen packages available on Adjusting the Output currentLayerOutput current adjustable / masterCONFIGURATOR, ready2mains, I-select 2 plug, resistorEXCready2mains, I-select 2 plug, resistorTW DT8 DALI / masterCONFIGURATOR, I-select 2 Plug, resistor2xCH / 4xCH DT 6 DALI / masterCONFIGURATOR, I-select 2 Plug, resistorAdjusting the output current via DALI or ready2mainsFurther information about DALI (see ) or ready2mains (see ) can be found in the correspondingDALI, p.

10 53ready2mains, p. function of the output current via I-select 2 plugBy inserting a suitable resistor into the I-select 2 interface, the current value can be most important data of the I-select 2 plug looks as follows:If the resistor is connected by wires a consistent base isolation must be ensured. Furthermore, a max. wire length of 2 m must not beexceeded. Potential interferences have to be avoided because they can cause additional tolerance to the output current. To ensure noinfluence of interferences on the resistor value use shielded wires to connect the I-select 2 plug. GND of shielded wire must beconnected to the corresponding I-select 2 plug terminal marked with GND in the data modules with on-board I-select 2 resistors may cause irreparable damages, caused by surge / burst resistor to set output current value_Compatible with LED Driver featuring I-select 2 interface.