Migration GuideOriginal InstructionsLegacy PanelView Terminals to PanelView plus 7 Terminals catalog number ConversionsAbout This PublicationThis publication provides information to help you convert Legacy 2711 PanelView Standard Terminals and 2711E PanelView Enhanced Terminals to these new generation Terminals : PanelView plus 7 Standard Terminals PanelView plus 7 Performance terminalsTo picPageAbout This Publication1 Summary of Changes2 Application Migration2 catalog number Explanations3 catalog number conversion Tables10 PanelView Standard 300 and 300 Micro Terminals Conversions10 PanelView Standard 550 Terminals Conversions11 PanelView Standard 600 Terminals Conversions15 PanelView Standard 900 Terminals Conversions19 PanelView Standard 1000 Terminals Conversions25 PanelView Standard 1400 Terminals Conversions31 PanelView Enhanced 1000e, 1200e.

Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions PanelView Standard 1000 Terminals Cat. No. Display Communication Ports Input Power Memory Keypad (1) Nonvolatile/RAM (1) Terminals with L1 added to the catalog number indicate DC power; for example, 2711-K10C3L1 or 2711-K10G3L1. Touch Size Type Comm RS-232 Print

Tags:

  Catalog, Plus, Number, Conversion, Panelview, 1172, Catalog number, To panelview plus, Catalog number conversions panelview

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Legacy PanelView Terminals to PanelView Plus 7 Terminals ...

1 Migration GuideOriginal InstructionsLegacy PanelView Terminals to PanelView plus 7 Terminals catalog number ConversionsAbout This PublicationThis publication provides information to help you convert Legacy 2711 PanelView Standard Terminals and 2711E PanelView Enhanced Terminals to these new generation Terminals : PanelView plus 7 Standard Terminals PanelView plus 7 Performance terminalsTo picPageAbout This Publication1 Summary of Changes2 Application Migration2 catalog number Explanations3 catalog number conversion Tables10 PanelView Standard 300 and 300 Micro Terminals Conversions10 PanelView Standard 550 Terminals Conversions11 PanelView Standard 600 Terminals Conversions15 PanelView Standard 900 Terminals Conversions19 PanelView Standard 1000 Terminals Conversions25 PanelView Standard 1400 Terminals Conversions31 PanelView Enhanced 1000e, 1200e.

2 And 1400e Terminals Conversions33 Accessories34 Legacy Communication Support34 Adapter Kit conversion Table35 Additional Resources352 Rockwell Automation Publication 2711P-AP005F-EN-P - July 2022 Legacy PanelView Terminals to PanelView plus 7 Terminals catalog number Conversions Migration GuideSummary of ChangesThis publication contains new and updated information as indicated in the following MigrationHuman Machine Interface (HMI) applications for PanelView plus 7 Terminals are created by using FactoryTalk View Studio for Machine Edition software. You can import PanelView Standard and Enhanced/PanelBuilder 32 applications into FactoryTalk View Studio as Machine Edition applications by using the Machine Edition Import Wizard.

3 The Import Wizard takes you through a series of steps, such as scaling to a new screen resolution size, and then converts objects, text, tags, and communication configurations to ones that are available in Machine Edition software. See the Migrating PanelView Standard Applications to PanelView plus 7 Migration Guide, publication DifferencesWhat impact does the resolution have when you run a PanelView Standard or Enhanced terminal application on a PanelView plus 7 terminal ? The PanelView plus 7 Terminals have greater resolution than the PanelView Standard or Enhanced Terminals . If you do not resize the application, the application runs in the top-left of the terminal. This issue is true for FactoryTalk View ME station platforms.

4 If you do resize the application, you can go into each screen and adjust the position and layout of the objects. This is especially useful when you convert from a normal screen to a wide the terminal is set to allow desktop access and the shell type is set to open, these issues occur: The application does not resize to match the resolution of the screen. The application does not cover the screen. The Windows CE desktop is exposed, and can be activated by the terminal is set to disallow desktop access and the shell type is set to close, these issues occur: The application does not resize to match the resolution of the screen. The application does not cover the screen. The FactoryTalk View ME station is exposed, and cannot be activated by Migration for CommunicationAll PanelView Standard and Enhanced terminal applications that are set to serial communication must be changed to Ethernet communication for PanelView plus 7 picPagesCorrected the cutout dimensions of the PanelView Standard Automation Publication 2711P-AP005F-EN-P - July 20223 Legacy PanelView Terminals to PanelView plus 7 Terminals catalog number Conversions Migration GuideCatalog number ExplanationsThis section provides a description of the catalog numbers for the standard and enhanced 300 Monochrome TerminalsCat.

5 MemoryNonvolatile/RAMSizeType2711-K3A2L1 (1)(1) Terminals with a DH-485 communication port require application uploads and downloads through the communication port. The RS-232 printer port is only for DC240 KB/170 KB2711-K3A5L1(1)RS-232 (DH-485)2711-K3A5L1K(1)(2)(2)K at the end of a catalog number means that the terminal is (DH-485)2711-K3A10L1 DeviceNet and RS-2322711-K3A17L1(3)(3)This terminal does not have an RS-232 printer port. Use the communication port to download or upload application (DF1) PanelView 300 Micro TerminalsCat. No.(1)(1)These Terminals do not have an RS-232 printer port. Use the communication port to upload and download application files. InputDisplay CommunicationPower Nonvolatile (DF1)8-pin mini DINDC240 KB2711-M3A19L1RS-232 (DH-485)8-pin mini DINP anelView Standard 550 TerminalsCat.

6 PortsMemoryNonvolatile/RAMK eypad(1) (2) (3)(1)Touch Terminals with L1 at the end of the catalog number support only DC power. Keypad or keypad/touch Terminals with L1 added to the catalog number indicate DC power; for example, 2711-K5A10L1.(2)L2 added to the catalog number of keypad or keypad/touch Terminals indicate a stainless steel terminal with AC power; for example, 2711-K5A5L2.(3)L3 added to the catalog number of keypad or keypad/touch Terminals indicate a stainless steel terminal with DC power; for example, uc h(1)Keypad/Touch(1)(2)(3) SizeTypeCommRS-232 MonochromeDH-485(4)(4) Terminals with DH-485 communication require that you upload or download applications by using the communication port. The RS-232 port on these Terminals is only for KB/170 KB2711-K5A32711-T5A3L12711-B5A3DH-485(4) Ye s2711-K5A52711-T5A5L12711-B5A5RS-232 (DH-485)(4)No2711-K5A92711-T5A9L12711-B5 A9RS-232 (DH-485)(4)Ye s2711-K5A12711-T5A1L12711-B5A1 Remote I/OYes2711-K5A82711-T5A8L12711-B5A8DH+ Yes2711-K5A102711-T5A10L12711-B5A10 DeviceNetYes2711-K5A122711-T5A12L12711-B 5A12RS-232 Yes2711-K5A142711-T5A14L12711-B5A14 DeviceNetYes2711-K5A152711-T5A15L12711-B 5A15 ControlNet Yes2711-K5A162711-T5A16L12711-B5A16RS-23 2 (DF1)Yes (download also)

7 2711-K5A202711-T5A20L12711-B5A20 EtherNet/IP Yes4 Rockwell Automation Publication 2711P-AP005F-EN-P - July 2022 Legacy PanelView Terminals to PanelView plus 7 Terminals catalog number Conversions Migration GuidePanelView Standard 600 TerminalsCat. PortsMemoryNonvolatile/RAMK eypad(1) (1)Touch Terminals with L1 at the end of the catalog number support only DC power. Keypad or keypad/touch Terminals with L1 added to the catalog number indicate DC power; for example, (1)Keypad/Touch(1) SizeTypeCommRS-232 Print2711-K6C22711-T6C2L12711-B6C25-in. ColorDH-485 (2)(2) Terminals with DH-485 communication require that you upload or download applications by using the communication port. The RS-232 port on these Terminals is only for KB/170 KB2711-K6C32711-T6C3L12711-B6C3DH-485(2) Ye s2711-K6C52711-T6C5L12711-B6C5RS-232 (DH-485)(2)No2711-K6C92711-T6C9L12711-B6 C9RS-232 (DH-485)(2)Ye s2711-K6C12711-T6C1L12711-B6C1 Remote I/OYes2711-K6C82711-T6C8L12711-B6C8DH+Ye s2711-K6C102711-T6C10L12711-B6C10 DeviceNetYes2711-K6C122711-T6C12L12711-B 6C12RS-232 Yes2711-K6C142711-T6C14L12711-B6C14 DeviceNetYes2711-K6C152711-T6C15L12711-B 6C15 ControlNetYes2711-K6C162711-T6C16L12711- B6C16RS-232 (DF1)Yes (download also)

8 2711-K6C202711-T6C20L12711-B6C20 EtherNet/IPYesRockwell Automation Publication 2711P-AP005F-EN-P - July 20225 Legacy PanelView Terminals to PanelView plus 7 Terminals catalog number Conversions Migration GuidePanelView Standard 900 Terminals Cat. PortsInput PowerMemoryNonvolatile/RAMK eypad(1) (1) Terminals with L1 added to the catalog number indicate DC power; for example, 2711-K9C10L1 or u c h(1) SizeTypeCommRS-232 I/OYesAC1008 KB/310 KB2711-K9C32711-T9C3DH-485(2)(2)Terminal s with DH-485 communication require that you upload or download applications by using the communication port. The RS-232 port on these Terminals is only for s2711-K9C82711-T9C8DH+Yes2711-K9C92711-T 9C9RS-232 (DH-485)(2)Ye s2711-K9C102711-T9C10 DeviceNetYes2711-K9C122711-T9C12RS-232 Yes2711-K9C142711-T9C14 DeviceNetYes2711-K9C152711-T9C15 ControlNetYes2711-K9C162711-T9C16RS-232 (DF1)Yes (download also)2711-K9C202711-T9C20 EthernetYes2711-K9A12711-T9A1 GrayscaleRemote I/OYes2711-K9A22711-T9A2DH-485(2)No2711- K9A32711-T9A3DH-485(2)Ye s2711-K9A52711-T9A5RS-232 (DH-485)(2)No2711-K9A82711-T9A8DH+Yes271 1-K9A92711-T9A9RS-232 (DH-485)(2)Ye s2711-K9A102711-T9A10 DeviceNetYes2711-K9A122711-T9A12RS-232 Yes2711-K9A14L12711-T9A14L1 DeviceNetYesDC2711-K9A152711-T9A15 ControlNetYesAC2711-K9A162711-T9A16RS-23 2 (DF1)Yes (download also)

9 6 Rockwell Automation Publication 2711P-AP005F-EN-P - July 2022 Legacy PanelView Terminals to PanelView plus 7 Terminals catalog number Conversions Migration GuidePanelView Standard 1000 TerminalsCat. PortsInput PowerMemoryNonvolatile/RAMK eypad(1) (1) Terminals with L1 added to the catalog number indicate DC power; for example, 2711-K10C3L1 or h(1) SizeTypeCommRS-232 (2)(2) Terminals with DH-485 communication require that you upload or download applications by using the communication port. The RS-232 port on these Terminals is only for sAC1008 KB/310 KB2711-K10C92711-T10C9RS-232 (DH-485)(2)Ye s2711-K10C12711-T10C1 Remote I/OYes2711-K10C82711-T10C8DH+Yes2711-K10 C102711-T10C10 DeviceNetYes2711-K10C122711-T10C12RS-232 Yes2711-K10C142711-T10C14 DeviceNetYes2711-K10C152711-T10C15 ControlNetYes2711-K10C162711-T10C16RS-23 2 (DF1)Yes (download also)2711-K10C202711-T10C20 (2)Ye sAC1008 KB/310 KB2711-K10G92711-T10G9RS-232 (DH-485)(2)Ye s2711-K10G12711-T10G1 Remote I/OYes2711-K10G82711-T10G8DH+Yes2711-K10 G102711-T10G10 DeviceNetYes2711-K10G122711-T10G12RS-232 Yes2711-K10G142711-T10G14 DeviceNetYes2711-K10G152711-T10G15 ControlNetYes2711-K10G162711-T10G16RS-23 2 (DF1)Yes (download also)

10 2711-K10G202711-T10G20 EtherNet/IPYesPanelView Standard 1400 TerminalsCat. PortsInput PowerMemoryNonvolatile/RAMK eypad Touch SizeTypeCommRS-232 I/OYesAC1008 KB/310 KB2711-K14C32711-T14C3DH-485(1)(1)Termin als with DH-485 communication require that you upload or download applications by using the communication port. The RS-232 port on these Terminals is only for s2711-K14C82711-T14C8DH+Yes2711-K14C9271 1-T14C9RS-232 (DH-485)(1)Ye s2711-K14C102711-T14C10 DeviceNetYes2711-K14C122711-T14C12RS-232 Yes2711-K14C142711-T14C14 DeviceNetYes2711-K14C152711-T14C15 ControlNetYes2711-K14C162711-T14C16RS-23 2 (DF1)Yes (download also)2711-K14C202711-T14C20 EthernetYesRockwell Automation Publication 2711P-AP005F-EN-P - July 20227 Legacy PanelView Terminals to PanelView plus 7 Terminals catalog number Conversions Migration GuidePanelView Enhanced TerminalsCatalog number Product Description2711E-T10C6 1000e Touch Screen TerminalColor display, clip mount, NEMA 4X2711E-K10C6 1000e Keypad Terminal Color display, clip mount.