Lettered Model Numbers A Model number starting with two or three letters followed by the size of the unit has been used extensively and is current nomenclature policy. The first two letters designate the Model series. The third letter is normally used for the unit configuration: vertical upflow (V), horizontal (H), and down discharge (D). The next three digits (sometimes only two) after Model series is the unit cooling capacity in thousands of BTUH. 036 is 36,000 BTUH. A ton is 12,000 BTUH, some the 036 is a three-ton unit. After the first 5 or 6 digits, the function of the digit has varied over time. The current standard (for most package units) is: 7- revision letter, 8- voltage, 9- control system, 10 cabinet insulation and filter rack, 11 water options or belt drive selection, 12- heat exchanger options, 13 & 14- Airflow options, and 15- is for standard or special order. Some variance exists by type of unit.

The first two letters designate the model series. The third letter is normally used for the unit configuration: vertical upflow (V), horizontal (H), and down discharge (D). The next three digits (sometimes only two) after model series is the unit cooling capacity in …

Tags:

  First, Model

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Lettered Model Numbers - ClimateMaster

1 Lettered Model Numbers A Model number starting with two or three letters followed by the size of the unit has been used extensively and is current nomenclature policy. The first two letters designate the Model series. The third letter is normally used for the unit configuration: vertical upflow (V), horizontal (H), and down discharge (D). The next three digits (sometimes only two) after Model series is the unit cooling capacity in thousands of BTUH. 036 is 36,000 BTUH. A ton is 12,000 BTUH, some the 036 is a three-ton unit. After the first 5 or 6 digits, the function of the digit has varied over time. The current standard (for most package units) is: 7- revision letter, 8- voltage, 9- control system, 10 cabinet insulation and filter rack, 11 water options or belt drive selection, 12- heat exchanger options, 13 & 14- Airflow options, and 15- is for standard or special order. Some variance exists by type of unit.

2 The G# series units were the current models until 2010, when units were required to change from R-22 to R-410A. The TC, TR, TS are almost identical to the GC, GR, and TS units. Revision number (digit 7) may have changed, and some options have changed. Often, changing the first and sometime the seventh digits is all that is required to get the current equivalent unit. Please note that the letter H as the first digit, represents two possibilities. The unit can be a typical ClimateMaster Model number or it can designate it has been re-branded for the Heat Controller company to sell. For some time in our earlier history we made PTAC s (packaged terminal air conditioners) which were through the wall units and air cooled. We no longer make any PTAC units and refer customers to others. We made PTAC s with both letter Model Numbers and numbered Model Numbers (700 series). The left most added text box (in red) indicates first the equipment general type such as horizontal package or water to water units.

3 The second box (if included) indicates suggested replacement in current ClimateMaster Model Numbers . NRA means no replacement available. ISSUED:ENG:DATE:DATE:DRAWN:DATE: ,OK731797300SW44thDRAWINGNO:MP8/14/17 Decoder EC Large CapacityDecoder EC Large CapacityDR8/14/1717-03268/14/171-2 SEE PAGE 2 FOR REVISION HISTORYDWG #:Decoder ECLarge CapacityTCHECHTCVECVECHA0 9 6CH3 AAL SS1 234 5 678910111213 1415EC = ENERTECH COMPACT COMMERCIAL R410 AMODEL TYPEH = HORIZONTALCONFIGURATION072 UNIT SIZE096120 REVISION LEVELA = CURRENT REVISIONVOLTAGEC = CXMCONTROLSD = DXML = CXM w/LONM = DXM w/LONN = CXM w/MPCP = DXM w/MPCBLOWER DRIVE PACKAGEHEAT EXCHANGER OPTIONSLB = LEFT RETURN/BACK DISCHARGEAIR FLOW OPTIONSLS = LEFT RETURN/STRAIGHT DISCHARGERB = RIGHT RETURN/BACK DISCHARGES = STANDARDZ 2 SRS = RIGHT RETURN/STRAIGHT DISCHARGEVB = LEFT RETURN DRAIN PAN/BACK DISCHARGEVS = LEFT RETURN DRAIN PAN/STRAIGHT DISCHARGEETL ApprovedUSA & CanadaA = STANDARD RPM & STANDARD MOTORB = LOW RPM & STANDARD MOTORC = HIGH RPM & STANDARD MOTORD = STANDARD RPM & LARGE MOTORE = HIGH RPM & LARGE MOTORWB = RIGHT RETURN DRAIN PAN/BACK DISCHARGEWS = RIGHT RETURN DRAIN PAN/STRAIGHT DISCHARGEA = DUAL POINT POWERV =

4 VERTICALTCHONLYBF = BACK RETURN/FRONT DISCHARGEBT= BACK RETURN/TOP DISCHARGEFB = FRONT RETURN/BACK DISCHARGEFT = FRONT RETURN/TOP DISCHARGEYF = BACK RETURN DRAIN PAN/FRONT DISCHARGEYT = BACK RETURN DRAIN PAN/TOP DISCHARGEZB = FRONT RETURN DRAIN PAN/BACK DISCHARGEZT = FRONT RETURN DRAIN PAN/TOP DISCHARGETCVONLY160192240300}VERTICAL ONLYCABINET INSULATION / FILTER RAILS/FRAMESOPTIONRANGE2 FILTERRAILS/FRAMES4 FILTERRAILS/FRAMES1 ABCDEFGHMUTENONOYESYESNONONONONONONONOYE SYESYESYESYESYESYESYES1 FILTERRAILS/FRAMESYESNOYESNOYESNOYESNONO NONONO234W = WIRE DIAGRAM SPECIALOPTIONACJN1234 NON-COATEDAIR COILCOPPERCUPRO-NICKELWATER COILCOATED COILWATER SIDEECONOMIZERNOYESYESYESNONOYESLOWAIRSI DEPRESSURENONOWATER COILYESNOYESNOYESNOYESYESNOYESNONOYESNON OYES{EnertechSeriesCross Match TableClimateMasterSeriesH = 208-230/60/3 (FACTORY WIRED 208)F = 460/60/3N = 575/60/3{NOTES:1. All units come standard with 100zVA 208-230 Volt units wired for 208 Volt service3.}

5 Refer to blower performance table in Spec catalogto determine correct Drive Horizontal Units come standard with Filter Frames ordered as Units come standard with Filter Rails ordered as For Mute option, compressor incorporates rubber grommetmounting system, blower housing and Air Handler compartmentare covered with high density noise suppression When digit 12 = option 1 , 2 , 3 or 4 digit 9 must beoption D , M or P When Digit 12 = option 1 , 2 , 3 or 4 digit 10 must beoption 1 , 2 , A , B , C , or D .231{{45767 REVDESCRIPTIONBYPCNDATEAPPROVEDISSUED:EN G:DATE:DATE:DRAWN:DATE: ,OK731797300SW44thDRAWINGNO:MP11/02/04 DECODER ERVD ecoder ERVDR11/02/0404--040611/02/04G1-1-SEE PAGE 2 FOR REVISION HISTORYGUPDATED OPTIONS ON DIGIT 11 DWG #:Decoder ERVTM11/2/1010-0520 MPZ23 REVE R VAA1 2 311 Model TYPEC abinet Size4A12 RevisionSupply/Exhaust Damper OptionsB5 VoltageF6A7 ControlsA = Stand alone ERVA8C = Stand Alone ERV with Economizer ModeFiltersA = 2 MERV 8 PleatedA9 Protection / Preheat OptionsA = NoneB = Frost ProtectionA10 Monitor OptionsA = NoneB = Filter Maintenance IndicatorC = Low Temperature LockoutD = B + CERV = Energy Recovery VentilatorA = 1000 - 1600 CFMF = 460/60/3G = 208-230/60/1H = 208-230/60/3N = 575/60/3B = Mated ERVB = 4 MERV 8 PleatedC = 4 MERV 13 PleatedE = 5 KwG = 15 KwH = 20 KwC = Airflow CFM MonitorD = None / MotorizedB =Motorized / MotorizedC = Motorized / BarometricA13 Power TerminationA = NoneB = Non-fused DisconnectA14 Motor HPB = CurrentB = 1601 - 2600 CFMC = 2601 - 5500 CFMD = 5501 - 10000 CFMF = 10 KwA = None / BarometricWheel SelectionA = StandardS15 StandardS = StandardA, B.}}

6 C = SPECIAL 1, 2, 3 = Mated ERV with Economizer ModeNotes:1. If digit 13 is B , digit 15 can no longer be S and must change to A,B,C = C with Stop/Jog ControlF = D with Stop/Jog Control1B = Custom Selection1C = Fused DisconnectA = 1HP, ( A Cabinet Only)B = , ( A & B Cabinet Only)C = 2HP, ( B & C Cabinet Only)D = 3HP, ( B & C Cabinet Only)E = 5HP, ( C & D Cabinet Only)F = , ( D Cabinet Only)G = 10HP, ( D Cabinet Only)G series were the units before the TC. G series units used R-22 and T series units use R-410A. G and T units are very similar and are close to an exact dimensional = TCGS = TSGR = TRGL = TL15 The Smart Choice for Energy EfficiencyThhe Smart Choice for EnergWater FlowWater Pressure DropWater Flow (L/s) = gpm x (kPa) = PD (ft of hd) x CalculationsConversion Table - to convert inch-pound (English) to SI (Metric)Legend and Glossary of AbbreviationsModel NomenclatureLWT = EWT -HEGPM x 500 LWT = EWT +HRGPM x 500 HeatingCooling BTUH = BTU( British Thermal Unit) per hour COP = coeffi cient of performance = BTUH output/BTUH input EER = energy effi ciency ratio = BTUH output/Watt input EWT = entering water temperature GPM = water fl ow in gallons/minute HE = total heat of extraction, BTUH HC = heating capacity, BTUH HR = total heat of rejection, BTUH HWC = hot water generator (desuperheater)

7 Capacity, Mbtuh KW = total power unit input, kilowatts LOAD = heat exchanger used as evaporator in cooling, condenser in heating LWT = leaving water temperature, F MBTUH = 1000 BTU per hourSOURCE = heat exchanger used as condenser in cooling, evaporator in heating TC = total cooling capacity, BTUH WPD = waterside pressure drop (psi & ft. of hd.)G LWB3 6 0CF1 ABRBS1 234 5 6789101112 131415GL = Genesis LargeModel TypeW = Water-To-WaterConfigurationUnit Size360 Revision LevelB = Current RevisionVoltageControls2 = Extended Range w/UltraQuietCabinet InsulationOptionsB = Brazed Plate HX w/Stainless Steel PlatesSource Water Coil OptionsB = Brazed Plate HX w/Stainless Steel PlatesLoad Water Coil OptionsStandard1 = Extended RangeB = Disconnect SwitchA = StandardR = RightWater Connection LocationS = StandardC = CXMD = DXML = CXM w/LONM = DXM w/LONF = 460/60/3H = 208-230/60/3N = 575/60/3N = CXM w/MPCP = DXM w/MPCRev.

8 : 10/04/05D GO Series Nomenclature SIDE WATER 2 CONNECTION BOTTOM WATER CONNECTION NON COATED AIR COIL B C E. COATED AIR COIL K L 1 2 3 4 5 6 7 9 10 11 12 13 14 15 Model TYPE GO = GENESIS (R22) OUTSIDE AIR TO = TRANQUILITY (R410A) OUTSIDE AIR CONFIGURATION HD = HORIZONTAL NO WHEEL HW = HORIZONTAL w/ WHEEL RD = ROOFTOP (OUTDOOR) NO WHEEL RW = ROOFTOP ( OUTDOOR ) w/ WHEEL VF = VERTICAL w/ FILTER BOX (STANDARD) VD = VERTCAL w/DAMPER BOX S = STANDARD SUPPLY AIR CONFIGURATION T = TOP B = BOTTOM DISCHARGE (HORIZONTAL AND ROOFTOP ONLY) A= REAR DISCHARGE (HORIZONTAL AND ROOFTOP ONLY) RETURN AIR CONFIGURATION N = NONE (100% OUTSIDE AIR) - NON-WHEELED UNITS (STANDARD) A= REAR RETURN (HW/RW ONLY) B = BOTTOM RETURN (HW/RW ONLY) HEAT EXCHANGER OPTIONS ALL { UNIT SIZE 03 - (HD, RD) 04 - (VD, VF) 05 08 CONFIGURATIONS 10 15 20 25 HD / RD CONFIGURATION { 30 36 40 46 50 56 60 80 99 BLOWER DRIVE PACKAGE (SEE BLOWER TABLES FOR DETAIL)}}

9 A= DRIVE PACKAGE 1 B = DRIVE PACKAGE 2 C = DRIVE PACKAGE 3 D = DRIVE PACKAGE 4 E = DRIVE PACKAGE 5 F = DRIVE PACKAGE 6 G = DRIVE PACKAGE 7 CABINET CONFIGURATION 1 1 = EXTENDED RANGE, RH SERVICE ACCESS (HORIZONTAL & ROOFTOP ONLY) 2 = EXTENDED RANGE, LH SERVICE w/ ULTRA QUIET (VERTICAL SIZES 04 - 15 ONLY) 3 = EXTENDED RANGE, LH SERVICE ACCESS REVISION LEVEL A= JCI B = CAREL CONTROLS / MISC OPTIONS E = LAT (STANDARD) H = LAT (STANDARD), VFD FOR WHEEL (HW & RW ONLY) J = ZONE RESET M = ZONE RESET, VFD FOR WHEEL (HW & RW ONLY) VOLTAGE G = 208-230/60/1 (SIZES 03 - 05 ONLY) H = 208-230/60/3 F = 460/60/3 N = 575/60/3 LH O/A > (FRONT) REAR Notes: 1. SERVICE ACCESS SIDE REFERENCED LOOKING INTO O/A INTAKE. 2. SIDE WATER CONNECTIONS ARE ALWAYS ON THE SAME SIDE AS ACCESS EXCEPT FOR HORIZONTAL SIZE 20. WATER CONNECTIONS FOR HORIZONTAL SIZE 20 ARE ON SIDE OPPOSITE TO ACCES SIDE. 3. CONDENSATE CONNECTION SAME SIDE AS WATER CONNECTIONS.

10 RH S T N B A 3 E F B 30 VF TO TOP VIEW Some H units are marketed as Heat ControllerREVDESCRIPTIONBYPCNDATEAPPROVE DISSUED:ENG:DATE:DATE:DRAWN:DATE: ,OK731797300SW44thDRAWINGNO:WW10/11/05 Decoder HCDecoder H CTM10/11/0505 - 034410/11/05A1-1-INITIAL RELEASEAB---UPDATE DIGIT 11, OPTION #:Decoder HC- -- -- -TM10/11/0505-0344WW- -- -/- -/- -- - - - - - -- -- -- -/- -/- -- - - - - - -- -TM08/17/0707-0326- -- -/- -/- -- - - - - - -- -TM01/05/0707-0009 WWADDED OPTION 4 TO DIGIT CHB0 3 6C330 ALB1 234 5 67891011121314HC = HEAT CONTROLLER COMPACTMODEL TYPEH = HORIZONTAL (NON PAINTED)CONFIGURATIONV = VERTICAL (PAINTED POLAR ICE)006 - 1,8 (HCH Only)UNIT SIZE009 - 1,8012 - 1,8018 - 1,8024 - 1,3,4,8030 - 1,3,4,8036 - 1,3,4,8041 - 1,3,4, (HCV Only)042 - 1,3,4,5048 - 1,3,4,5060 - 1,3,4,5 REVISION LEVELB = CURRENT REVISION FOR SIZES 006 - 060 VOLTAGEC = CXMCONTROLS3 = STANDARD RANGECABINET INSULATION0 = NONEFUTURE USEA = Copper Water Coil w/E-Coated Air CoilHEAT EXCHANGER OPTIONSC = Copper Water Coil w/Non-Coated Air CoilL = LEFT RETURNRETURN AIR OPTIONSR = RIGHT RETURNF = FRONT RETURN, VERTICAL 009-030 and 041 onlyB = BACK DISCHARGE, HORIZONTAL ONLYSUPPLY AIR OPTIONSY = BACK DISCHARGE, HIGH STATIC HORIZONTAL 018 - 060, But Not 041T = TOP DISCHARGE, VERTICAL ONLYV = TOP DISCHARGE, HIGH STATIC VERTICAL 018 - 060, But Not 041S = STRAIGHT DISCHARGE, HORIZONTAL ONLYZ = STRAIGHT DISCHARGE, HIGH STATIC HORIZONTAL 018 - 060, But Not 041J = Cupro-Nickel Water Coil w/E-Coated Air CoilN = Cupro-Nickel Water Coil w/Non-Coated Air Coil 009-030 and 041 only4 = STANDARD RANGE.