Linear Transducers - Rota Eng

Linear TransducersRota Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel: +44 (0) 161 764 Position Sensing Technologyfor Mobile ApplicationsNew TechnologyHydraulic cylinder users are alwayslooking for a more cost effective methodof fitting Linear Transducers as deep holedrilling can be particularly rota , using patent applied fortechnology, have designed a lineartransducer that can be simply mountedexternally onto a standard carbon steelcylinder wall. The cylinder position ismeasured when a magnet, pre-fitted inthe piston, is moved by steering cylinders can nowbe monitored by a Linear our existing solid state Hall Effectlinear Transducers have improvedaccuracy options and reduced deadlengths for even easier fitting into shortpin to pin length also have a totally new combinedlinear & pressure transducer , capable ofmonitoring long strokes with workingpressures up to 720 bar (10,500 psi).

Linear Transducers Rota Engineering Ltd Wellington Street, Bury, Manchester, BL8 2BD, UK Tel: +44 (0) 161 764 0424 info@rota-eng.com www.rota-eng.com

Tags:

  Linear, Transducer, Rota, Linear transducers rota eng, Linear transducers rota

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Linear Transducers - Rota Eng

1 Linear TransducersRota Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel: +44 (0) 161 764 Position Sensing Technologyfor Mobile ApplicationsNew TechnologyHydraulic cylinder users are alwayslooking for a more cost effective methodof fitting Linear Transducers as deep holedrilling can be particularly rota , using patent applied fortechnology, have designed a lineartransducer that can be simply mountedexternally onto a standard carbon steelcylinder wall. The cylinder position ismeasured when a magnet, pre-fitted inthe piston, is moved by steering cylinders can nowbe monitored by a Linear our existing solid state Hall Effectlinear Transducers have improvedaccuracy options and reduced deadlengths for even easier fitting into shortpin to pin length also have a totally new combinedlinear & pressure transducer , capable ofmonitoring long strokes with workingpressures up to 720 bar (10,500 psi).

2 A new explosive atmosphere, intrinsicallysafe, ATEX and IEC Ex approved lineartransducer for surface and undergroundapplications. LA/B series is the smallest active transducer on the market, using a clip in mounting it does not change the pin to pin dimension on existing cylinder designs Optional 5 VDC powered transducer gives VDC output, allows customer to upgrade from resistive type Transducers to non-contact Hall Effect without upgrading the mobile equipment electronics Submersible sensors capable of 6,000m ocean depths Sensors from 60mm up to 15m length, and working pressures of up to 720bar ATEX , IEC approved sensors for hazardous area applications Internal and External cylinder designs and Independent Mount.

3 Dual circuit and radial versions All models give an absolute signal from inbuilt electronicsNon-Contact, Absolute, Hall Effect SensorsRota Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel: +44 (0) 161 764 here to send enquiry2 rota Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel: +44 (0) 161 764 Reed Switch technology in the early 90 s for mining then into offshore and subsea switch technology has good vibrationresistance and well sealed. With their low power input they are ideal for Intrinsically Safe and battery powered wire, 4 20 mA loop powered switch technology is limited by Hall Effect was introduced in the early 00 and robust construction, proved to be very improves > 10x compared to fast position package size so small it does not increase the critical pin to pin dimension of most existing cylinder designs, opens the door to more based sensor allows great design volume drives down cost, improves Switch TechnologyHall Effect TechnologyClick here to send enquiry3 Integrated TransducerRota Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel.

4 +44 (0) 161 764 electronics built insideNon contact operationMiniature mountingAbsoluteSignalShort length maintains pin to pin dimensionsAnalogue or digital outputs -High cycling and vibration lifeMounting OptionsScrew in headsQuick mount connectorsPush fit / Grubscew mountingPre assembledConnectorOverviewClick here to send enquiry4 Integrated MountingRota Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel: +44 (0) 161 764 LA Transducers use the latest version of even more compact electronics, all packaged in a very cost effective, high tensile aluminium enclosure rated to 325 bar (4750psi) operatingpressure. Its cost effective design makes it ideal for replacing limit switches, brackets and the associ-ated cables, potentiometers etc where the 5 volt supply option is LAC clip-in version is extremely compact and excellent for welded cylinders with eyes, clevises etc requiring no increase in the cylinder pin to pin mounting length.

5 Together with the prewired M12 connector the clip in trans-ducer design allows quick cost effective use in volume cylinder contact insertM12 Connector BodyAttach a length of cord to the inserts holes, feed cord through the machined hole to pull the transducer the insert all the way through the cylinder, then push transducer into placeuntil it clicks the metal M12body over the insertAlign connector and push into recess and secure into place with standard circlipQuick assembly M12 connectorExternal Linear TransducerClick here to send enquiry5 rota Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel: +44 (0) 161 764 sitereplaceableMagnet works throughcarbon steelNo deep drillingcostsNo extraend capcostsAbsolute non contact operationHigh cycling and vibration resistanceMaintains piston rod and end cap strengthExternal mounted transducerSteering CylindersLong Stroke CylindersRedundancyClick here to send enquiry6 External MountingThere are several advantages that stem from thistechnological approach:- The cost of achieving a smart cylinder is reduced by eliminating the need for gun-drilling the piston rod and end cap machining.

6 Accuracy of the transducer is typically +/- ( in) which is more than adequate for most mobile equipment. The transducer is easily field replaceable. The cylinder is stronger, easier to assemble, install and service. The cylinders can be supplied with magnets already fitted, so that if the stroke sensing function is required, the transducer can be added at a later date. Full stroke monitoring of Steering cylinders. Two Transducers can be used for redundancy on safety critical applicationsPatent applied for technology, eliminates the need for a gun-drilled piston rod. A transducer is mounted on the cylinder barrel and detects the position of the cylinder s piston by sensing a magnetic field formed by a permanent magnet embedded in the piston.

7 As the piston rod extends or retracts, the magnetic field propagates through the standard carbon steel cylinder wall to communicate with the Linear Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel: +44 (0) 161 764 deep drillingExternal Linear TransducerClick here to send enquiryExternal Hall-effect Linear transducerModel LA/LBModel LMModel ELAI nternal mounting, Mobile equipmentInternal mounting, Mobile equipmentInternal mounting, Mobile equipment10mm diameterStrokes: LA - up to 2m LB - up to 3mPressure: LA - 325bar LB - 375barTemp up to: -40 to + 105C -40 to + 221 FKey Benefits: Low cost, compact10mm diameterStrokes: Up to 3m Pressure: 375barTemp up to: -40 to + 105C -40 to + 221 FKey Benefits: Very compact, Robust10mm diameterStrokes: Very long Steering CylindersKey Benefits: Very low installation costs Field replaceable Dual redundant optionElectricalOutputs Voltage, Current, PWM & Digital5V input optionResolutions: : : material: LA - Aluminium LB - St.

8 Steel 304 LMounting options: Clip in heads Screw in headsEnclosure material: St. Steel 304L All welded designMounting options: Push in head Screw in headsEnclosure material: AluminiumMounting options: Angled head Flat head Parallel offset headConnectors or CablesIngress Protection up to IP69 rota Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel: +44 (0) 161 764 here to send enquiryMechanical8 Special Designs Combination namur proximity switch and Linear transducer in one package Combination Linear position, pressure and temperature transducer Dual output Transducers for redundancy Higher temperature capability LT trans-ducer rated up to 150 C Flexibility to handle special outputs 90 and 360 radial Transducers Higher pressure ratings Long strokes ATEX, IEC or CSA certified for explosive atmospheres High ingress protection subsea Special design mountings Higher resolutionsRadialDual circuitIndependant MountRota Engineering LtdWellington Street, Bury, Manchester, BL8 2BD, UKTel.

9 +44 (0) 161 764 here to send enquiry