Fisher and Paykel INNERVATOR Nerve Stimulatorsautomaticallyadjust the output voltage to deliver a constant set current, providingleading edge technology that is simple to FEATURES Visual and audible current delivery indicators. Mute Button, Low Battery indicator Maximum output 80mA.(adjustable to 160mA for NS252 and NS272). Alarm for non-delivery of set current Repetitive stimulation patterns Powered by 3 x volt "AA" batteries. Compact and lightweight(170mm x 73mm x 43mm and just kg). Full range of accessories, including mounting non-programmable nerve NS242provides the most commonly used stimulation patterns,including single twitch, train-of-four, and tetanus stimulation patterns are also #200NS031lead setINNERVATOR programmable nerve the same features as the NS242, as well as double burststimulation and post tetanic count stimulation patterns.

NS232 NS242 NS252 NS272 27 www.bensonmedical.ca All Fisher and Paykel INNERVATOR Nerve Stimulatorsautomatically adjust the output voltage to deliver a constant set current, providing leading edge technology that is simple to use.

Tags:

  Benson

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Locator - Benson Medical Industries Inc.

1 Fisher and Paykel INNERVATOR Nerve Stimulatorsautomaticallyadjust the output voltage to deliver a constant set current, providingleading edge technology that is simple to FEATURES Visual and audible current delivery indicators. Mute Button, Low Battery indicator Maximum output 80mA.(adjustable to 160mA for NS252 and NS272). Alarm for non-delivery of set current Repetitive stimulation patterns Powered by 3 x volt "AA" batteries. Compact and lightweight(170mm x 73mm x 43mm and just kg). Full range of accessories, including mounting non-programmable nerve NS242provides the most commonly used stimulation patterns,including single twitch, train-of-four, and tetanus stimulation patterns are also #200NS031lead setINNERVATOR programmable nerve the same features as the NS242, as well as double burststimulation and post tetanic count stimulation patterns.

2 The NS252also provides custom tailored stimulation patterns that can beprogrammed into the device for use when #200NS031lead nerve all the nerve stimulator functions of the NS252with thenerve Locator functions of the leads #200NS033and # nerve Locator NS232delivers low current settings for regional nervelocation applications. Delivers single twitch stimulation pattern ondemand or at one second intervals. Maximum output current at 10ma. Includes lead # Nerve Stimulators | AccessoriesCARRYING CASE WITH BELT STIMULATOR LEADS(NON-SHROUDED)*.. m (48") with alligator clipsMOUNTING BRACKETfor all nerve slides over Innervator and is fitted with a 30mm parallelslide bracket.

3 Allows the Innervator to be mounted onto a pole orwall Locator LEADS(NON-SHROUDED)*.. m (60") w/ dome connector & alligator clipDIAGNOSTIC PROBE(SHROUDED)..200NS030 Limited life reusable (20 per box)NERVE STIMULATOR LEADS(SHROUDED).. m (48") with alligator clipsNERVE STIMULATOR LEADS(SHROUDED).. m (48") with 2mm pin STIMULATOR LEADS(SHROUDED).. m (48") with dome Locator LEADS(SHROUDED).. m (60") w/ dome connector & alligator clipNERVE Locator LEADS (SHROUDED).. (60") w/ alligator clip and 2mm pin connectorNERVE Locator LEADS(SHROUDED).. m (60") w/ dome clip and pin connector (for use w/ Braun Stimuplex regional block needle)NERVE STIMULATOR LEADS (SHROUDED).

4 (80") with alligator clipsFIXED POLE 19-45mm be used with a 200NS009 mounting MOUNTING be used with a 200NS009 mounting 19 mm diameter be used with a 200NS009 mounting bracket.* required for units with first two serial number digits lower than 96, and units onwhich first two digits are 96 and last five digits are lower than Nerve Stimulators |Locator200NS030200NS035900NS009900MR170 900MR030900MR082200NS037200NS033 NEW!