Example: dental hygienist

LONG DURATION - IEECO

long DURATION MCT LEAD CALCIUMNCT LEAD CALCIUMHCT LEAD CALCIUMGNB FloodedSECTION 2004-11 Cell TypeAmp-HourCapacity1 LengthWidthHeightNetPackedPer in104 lbs110 gal2-MCT-5*192159 mm283 mm464 mm48 kg50 in70 lbs74 galMCT-7288105 mm32 kg34 in88 lbs93 galMCT-9384130 mm40 kg42 in107 lbs113 galMCT-11480165 mm49 kg51 literOverall DimensionsApproximate WeightElectrolytePlate inPositive mm inNegative mm mmLONG DURATIONMCT LEAD CALCIUMCAPACITIES 190 TO 480 HOUR RATE TO @ 77 F (25 C)20 YEAR LIFE EXPECTANCYSPECIFICATIONSJar Styrene-Acrylonitrile (SAN) PlasticCover Acrylonitrile Butadiene Styrene (ABS) PlasticSeparators Microporous MaterialRetainers Fiberglass MatPosts Two (per cell) - " ( mm) SquarePost Seals Floating O Ring - Seal NutVents GNB Pre-Vent Flame ArresterLevel Lines High and Low - All Jar FacesElectrolyte Height Above plates - " ( mm)Electrolyte Withdrawal Tubes 2 per cellSediment Space.

Long Duration MCT — LEAD CALCIUM NCT — LEAD CALCIUM HCT — LEAD CALCIUM GNB Flooded SECTION 33.20 2004-11

Tags:

  Section, Long, Duration, Long duration

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of LONG DURATION - IEECO

1 long DURATION MCT LEAD CALCIUMNCT LEAD CALCIUMHCT LEAD CALCIUMGNB FloodedSECTION 2004-11 Cell TypeAmp-HourCapacity1 LengthWidthHeightNetPackedPer in104 lbs110 gal2-MCT-5*192159 mm283 mm464 mm48 kg50 in70 lbs74 galMCT-7288105 mm32 kg34 in88 lbs93 galMCT-9384130 mm40 kg42 in107 lbs113 galMCT-11480165 mm49 kg51 literOverall DimensionsApproximate WeightElectrolytePlate inPositive mm inNegative mm mmLONG DURATIONMCT LEAD CALCIUMCAPACITIES 190 TO 480 HOUR RATE TO @ 77 F (25 C)20 YEAR LIFE EXPECTANCYSPECIFICATIONSJar Styrene-Acrylonitrile (SAN) PlasticCover Acrylonitrile Butadiene Styrene (ABS) PlasticSeparators Microporous MaterialRetainers Fiberglass MatPosts Two (per cell) - " ( mm) SquarePost Seals Floating O Ring - Seal NutVents GNB Pre-Vent Flame ArresterLevel Lines High and Low - All Jar FacesElectrolyte Height Above plates - " ( mm)Electrolyte Withdrawal Tubes 2 per cellSediment Space.

2 95" ( )Specific Gravity @ 77 F (25 C)Inter-Cell Connectors Lead Plated Copper Hardware Type 316 Stainless SteelWLHGNB Flooded*2 cells per unit18 hour rate to VPC @ 77 F (25 C)Page DATA @ 77 F (25 C)MCT CELLSGNB FloodedEnd Voltage Voltage Voltage Voltage Voltage Voltage Voltage 3 Page 4 Cell TypeAmp-HourCapacity1 LengthWidthHeightNetPackedPer in160 lbs168 galNCT-7552187 mm368 mm562 mm72 kg76 liter178 lbs190 galNCT-971281 kg86 liter196 lbs208 galNCT-1186489 kg95 liter214 lbs226 galNCT-13100897 kg103 in250 lbs263 galNCT-151192235 mm572 mm114 kg120 liter268 lbs280 galNCT-171344122 kg127 in314 lbs330 galNCT-191520289 mm140 kg150 liter332 lbs350 galNCT-211680151 kg159 in397 lbs415 galNCT-231864370 mm180 kg189 liter415 lbs433 galNCT-252024189 kg197 liter433 lbs451 galNCT-272184197 kg205 liter462 lbs480 galNCT-312280210 kg218 liter479 lbs497 galNCT-332416218 kg226 liter496 lbs514 galNCT-352552226 kg234 literOverall

3 DimensionsApproximate WeightElectrolyteGNB FloodedLONG DURATIONNCT LEAD CALCIUMCAPACITIES 550 TO 2550 HOUR RATE TO @ 77 F (25 C)20 YEAR LIFE EXPECTANCYSPECIFICATIONS*Jar Styrene-Acrylonitrile (SAN) Plastic*Cover Acrylonitrile Butadiene Styrene (ABS) Plastic*Separators Microporous Material*Retainers Fiberglass Mat*Posts NCT 7-13 " (38 mm) square NCT 15-21 " (25 mm) squareNCT 23-35 " (38 mm) square*Post Seals Floating O Ring - Seal Nut*Vents GNB Pre-Vent Flame Arrester*Level Lines High and Low - All Jar Faces*Electrolyte Height Above plates - (70mm)*Electrolyte Withdrawal Tubes 2 per cell*Sediment Space " (27mm)*Specific Gravity @ 77 F (25 C)*Inter-Cell Connectors Lead Plated Copper*Optional Polycarbonate Jar and Cover UL 94 V-O/ 28% Rating NCT 19 to 21 Sizes OnlyPVC Jar and Cover UL 94 V-O/ 32% Rating NCT 19 to 21 Sizes OnlyPlate inPositive Plate381 mm inNegative Plate381 mm mmWHL18 hour rate to VPC @ 77 F (25 C) DATA @ 77 F (25 C)NCT CELLSEnd Voltage Voltage Voltage FloodedPage 5 Page DATA @ 77 F (25 C)

4 NCT CELLSEnd Voltage Voltage Voltage Voltage FloodedPage 7 Cell TypeAmp-HourCapacity1 LengthWidthHeightNetPackedPer in454 lbs476 galHCT 212240383 mm438 mm638 mm206 kg216 liter471 lbs493 galHCT 232456214 kg224 liter488 lbs510 galHCT 252664222 kg232 liter505 lbs527 galHCT 272864229 kg239 liter522 lbs544 galHCT 293056237 kg247 liter539 lbs561 galHCT 313232245 kg255 liter556 lbs578 galHCT 333408252 kg262 liter573 lbs595 galHCT 353560260 kg270 liter590 lbs612 galHCT 373696268 kg278 literOverall DimensionsElectrolyteLONG DURATIONTYPE HCT - LEAD CALCIUMCAPACITIES 2240 TO 3700 HOUR RATE TO @ 77 F (25 C)20 YEAR LIFE EXPECTANCYSPECIFICATIONS*Jar Styrene-Acrylonitrile (SAN) Plastic*Cover Acrylonitrile Butadiene Styrene (ABS) PlasticSeparators Microporous MaterialRetainers Fiberglass MatPosts Four - " Square ( mm)Post Seals Floating O Ring - Seal NutVents GNB Pre-Vent Flame ArresterLevel Lines High and Low - All Jar FacesElectrolyte Height above plates - " ( mm)Electrolyte Withdrawal Tubes 2 Per CellSediment Space " ( mm)Specific Gravity @ 77 F (25 C)Inter-Cell Connectors Lead Plated Copper*Optional Polycarbonate Jar and Cover UL 94 V-O 28% Limiting Oxygen Index ( )PVC Jar and Cover UL 94 V-O 32% Limiting Oxygen Index ( )Plate inPositive Plate444 mm381 inNegative Plate444 mm381 mmApproximate WeightLHGNB FloodedW18 hour rate to VPC @ 77 F (25 C) DATA @ 77 F (25 C)HCT CELLSEnd Voltage Voltage Voltage FloodedPage 8 Page DATA @ 77 F (25 C)

5 HCT CELLSEnd Voltage Voltage Voltage Voltage FloodedSECTION 2004-11 Exide Technologies The Industry Industrial Power, a division of Exide Technologies is aglobal leader in stored electrical energy solutions for all majorcritical reserve power applications and needs. Network powerapplications include communication/data networks, UPSsystems for computers and control systems, electrical powergeneration and distribution systems, as well as a wide range ofother industrial standby power applications. With a strongmanufacturing base in both North America and Europe and atruly global reach (operations in more than 80 countries) in salesand service, GNB Industrial Power is best positioned to satisfyyour back up power needs locally as well as all over the world.

6 Based on over 100 years of technological innovation the NetworkPower Division leads the industry with the most recognizedglobal brands such as ABSOLYTE , SONNENSCHEIN ,MARATHON , SPRINTER , and GNB FLOODED CLASSIC .They have come to symbolize quality, reliability, performanceand excellence in all the markets Technologies takes pride in its commitment to a betterenvironment. Its Total Battery Management program, anintegrated approach to manufacturing, distributing andrecycling of lead acid batteries, has been developed to ensurea safe and responsible life cycle for all of its Industrial PowerA division of Exide TechnologiesUSA - Tel: - Tel: Floo