Example: tourism industry

LV (600V) Dry-Type Transformers - Federal Pacific

LV (600V) Dry-Type Transformers Industrial Control Encapsulated 600 Volt Class Ventilated 600 Volt Class DOE 2016 Efficiency Compliant 2 Federal Pacific HistoryIn 1987, Electro-Mechanical acquired the Dry-Type transformer division of Federal Pacific Electric in Des Plaines, Illinois. It was moved to Bristol, Virginia and the name was changed to Federal Pacific (FP). A new 100,000 square foot facility was constructed where time-proven designs and modern technology were combined and deployed under new management. Expansion in early 1993 provided an additional 36,000 square feet of manufacturing Pacific TodayFederal Pacific is a major manufacturer of Dry-Type Transformers which serve the industrial, construction, commercial, mining, OEM and utility markets.

Buck-Boost Transformers - Application, Operation Selection ... The coils are electrically isolated from one another but magnetically linked through the core, allow-ing electrical power to be transferred from one coil to the other. Transformers are …

Tags:

  Buck, Isolated

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of LV (600V) Dry-Type Transformers - Federal Pacific

1 LV (600V) Dry-Type Transformers Industrial Control Encapsulated 600 Volt Class Ventilated 600 Volt Class DOE 2016 Efficiency Compliant 2 Federal Pacific HistoryIn 1987, Electro-Mechanical acquired the Dry-Type transformer division of Federal Pacific Electric in Des Plaines, Illinois. It was moved to Bristol, Virginia and the name was changed to Federal Pacific (FP). A new 100,000 square foot facility was constructed where time-proven designs and modern technology were combined and deployed under new management. Expansion in early 1993 provided an additional 36,000 square feet of manufacturing Pacific TodayFederal Pacific is a major manufacturer of Dry-Type Transformers which serve the industrial, construction, commercial, mining, OEM and utility markets.

2 The product scope is 50 VA through 10,000 KVA and 120 volts through 25,000 volts. The 600 volt class offering includes industrial control Transformers , encapsulated/compound-filled general purpose and buck -boost Transformers , ventilated designs for general purpose applications, electrostatically shielded Transformers and a complete line of motor drive isolation Transformers . The medium voltage offering includes core and coil Transformers , general purpose designs, pad-mount Transformers , unit substation Transformers , vacuum pressure impregnated Transformers (VPI), and vacuum pressure encapsulated (VPE) Transformers . K-Factor rated Transformers are offered for the entire product warehouse stocks have been implemented across the United States, ensuring quick delivery of all products anywhere in the Out The New Tools Available From Federal PacificOnline at the new Federal Pacific App buck /Boost Calculator Low Voltage Product Finder Amps/kVA Calculator Wiring Diagram Selector4 Table of ContentsTransformer Naming Convention.

3 5 Single Phase Quick Reference Guide .. 6 Three Phase Quick Reference Guide ..7 Transformer Basics ..8 Transformer Selection Consideration ..9-11 Dry-Type Transformers Overview & Application ..12 Sound Levels, Industry Standards & Certifications, Tested Performance ..13 Single-Phase Encapsulated Technical Data ..14 Single-Phase Ventilated Technical Data ..15 Three-Phase Encapsulated Technical Data ..16 Three-Phase Ventilated Technical Data ..17-25 Single-Phase Wiring Diagrams ..26-28 Three-Phase Wiring Diagrams ..29-38 buck -Boost Transformers - Application, Operation Selection buck -Boost Technical Data ..40 buck -Boost Selection Tables ..41-43 buck -Boost Connection Diagrams.

4 44-48 Epoxy Encapsulated Copper-Wound Industrial Control Transformers Selection Considerations ..49 Primary Fusing - Industrial Control ..50 Primary Overcurrent Protection ..51 Secondary Overcurrent Protection ..51 Industrial Control Transformers Technical Data ..52 Industrial Control Wiring Diagrams ..53 Motor Drive Isolation Transformers Motor Drive Isolation Technical Data ..54 Transformer AccessoriesTerminal Lug Kits ..55 Weather Shield Kits ..55 Wall Mount Brackets ..55 Primary Fuse Kit ..55 Glossary .. 56-575 Single & Three Phase Encapsulated and Ventliated Transformer Naming Convention(using T48LH2Y-75 as an example)TTypeT = Three Phase, VentilatedN = Three Phase, EncapsulatedS = Single Phase, VentilatedP = Single Phase, EncapsulatedK = Single Phase, buck Boost48 PrimarySingle or Three Phase20 = 20824 = 24048 = 480 60 = 600 Three phase primary windings will be Delta connected.

5 Single Phase Only1X = 120 x 2402X = 240 x 48027 = 277 LHMaterial/Temperature RiseAluminum UnshieldedAluminum ShieldedCopper ShieldedCopper Unshielded150 CLHSHCHGH115 CLFSFCFGF80 CLBSBCBGB2 YSecondarySingle Phase21 = 120/24012 = 12/2416 = 16/3224 = 24/48 Three Phase2Y = 208Y/1202D = 240/(120LT)*3Y = 380Y/21940 = 400Y/23142 = 480Y/277* 120LT applies to ventilated units only-SeparatorKVA Separator75 KVA(-K-Factor)K1 = has no identifierK4 = K4K13 = K13K20 = K20-N/TApplicable to encapsulated Transformers onlyN = No TapsT = Taps6 Single-Phase Transformer Quick Reference GuideSingle Phase Encapsulated TransformersPart Number = Family [-KVA] [-N/T] (P2X only for taps)ConductorTemp Rise(Celsius)ElectrostaticShieldPrimary/ SecondaryFamilyKVAA vailableTapsAvailableCU115 CN120x240V - 120/240V208V - 120/240V277V - 120/240VP1 XGF21P20GF21P27GF211, , 2, 3 NYY240x480V - 120 , , , , , , 1, 2N3[-T]480V - 120/240V600V - 120/240VP48GF21P60GF211, , 2, 3YY240x480V - 120/240VP2 XCF213 NAL115 CN120x240V - 120/240V208V - 120/240V277V - 120/240V240x480V - 120/240V480V - 120/240VP1 XLF21P20LF21P27LF21P2 XLF21P48LF215, , 10, 15 NYY[-T] (All), [-N] ( KVA)YY240x480V - 120/240VP2 XSF215N600V - 120/240VP60SF215, , 10, 15 YSingle Phase Ventilated Dry-Type TransformersPart Number = Family [-KVA]ConductorTemp Rise(Celsius)

6 ElectrostaticShieldPrimary/SecondaryFami lyKVAA vailableTapsAvailableAL150 CN208V - 120/240VS20LH2115, 25, 37, 50, 75, 100, 167YN240x480V - 120/240VS2 XLH21Y600V - 120/240VS60SH21CU150 CN240x480V - 120/240VS2 XGH21YS2 XCH21 Single Phase Encapsulated buck -Boost TransformersPart Number = Family [-KVA]ConductorTemp Rise(Celsius)ElectrostaticShieldPrimary/ SecondaryFamilyKVAA vailableTapsAvailableCU115 CN120x240V - 12/24V120x240V - 16/32V240x480V - 24 , , , , , ,1, 2, 3 NAL115 CN120x240V - 12/24V120x240V - 16/32V240x480V - 24/48VK1 XLF12K1 XLF16K2 XLF245 Single Phase FEC Epoxy Encapsulated (Industrial Control) TransformersPart Number = Family [VA] [Suffix]ConductorTemp Rise(Celsius)ElectrostaticShieldPrimary/ SecondaryFamilyKVAA vailableTapsAvailableCU55 CN240x480V - 120 VFA[VA] , , , , , , , , , - 115V220x440V - 110V240x480V - 24 VFB[VA]JK120x240V - 24 VFC[VA]JK208/277V - 120 VFF[VA]XK200/220/440V - 23/110V208/230/460V - 24/115V240/480V - 25/120 VFJ[VA]XK240x480V - 120 VFK[VA]JJ7 Three Phase Ventilated Drive Isolation Dry-Type TransformersPart Number = [KVA] FamilyConductorTemp Rise(Celsius)

7 ElectrostaticShieldPrimary/SecondaryFami lyKVAA vailableK-FactorAvailableTapsAvailableAL 150 CN230 , 11, 15, 20, 34, 40, 51, 63, 75, 93, 118, 145, 175, 220, 275, 330, 440, 550, 660, 750K1Y230 -460 YAFMD460 -230 YCEMD460 -460 YCFMD230 -575 YAHMD460 -575 YCHMD575 -230 YDEMD575 -460 YDFMD575 -575 YDHMDT hree-Phase Transformer Quick Reference GuideThree Phase Ventilated Dry-Type TransformersPart Number = Family [-KVA] [-K Factor] (K Factor only required for K4, K13 and K20 products)ConductorTemp Rise(Celsius)ElectrostaticShieldPrimary/ SecondaryFamilyKVAA vailableK-FactorAvailableTapsAvailableAL 150 CN208 -480Y480 -208Y480 -240 /120LT480 -380Y/219480 -400Y480 -480YT20LH42T48LH2YT48LH2DT48LH3YT48LH40 T48LH4215, 30, 45,75, ,150, 225,300, 500K1, K4K13, K20YY208 -208Y240 -208Y480 -208Y480 -240 /120LT600 -208YT20SH2YT24SH2YT48SH2YT48SH2DT60SH2Y 15, 30, 45,75, ,150, 225,300, 500K1, K4K13, K20115 CN208 -480Y480 -208Y480 -240 /120LT480 -380Y/219480 -400Y480 -480YT20LF42T48LF2YT48LF2DT48LF3YT48LF40 T48LF4215, 30, 45,75, ,150, 225,300, 500K1, K4K13, K20Y208 -208Y240 -208Y480 -208Y480 -240 /120LT600 -208YT20SF2YT24SF2YT48SF2YT48SF2DT60SF2Y 15, 30, 45,75, ,150, 225,300, 500K1, K4K13.

8 K2080 CN208 -480Y480 -208Y480 -240 /120LT480 -380Y/219480 -400Y480 -480YT20LB42T48LB2YT48LB2DT48LB3YT48LB40 T48LB4215, 30, 45,75, ,150, 225,300, 500K1, K4K13, K20Y208 -208Y240 -208Y480 -208Y480 -240 /120LT600 -208YT20SB2YT24SB2YT48SB2YT48SB2DT60SB2Y 15, 30, 45,75, ,150, 225,300, 500K1, K4K13, K20CU150 CY480 -208YT48CH2Y15, 30, 45, 75, , 150, 225, 300, 500K1, K4K13, K20115 CT48CF2Y80 CT48CB2 YThree Phase Encapsulated Dry-Type TransformersPart Number = Family [-KVA]ConductorTemp Rise(Celsius)ElectrostaticShieldPrimary/ SecondaryFamilyKVAA vailableK-FactorAvailableTapsAvailableCU 115 CN480 -208Y480 -240 N48GF2YN48GF2D3, 6N/AYY240 -208Y480 -208Y480 -240 N24CF2YN48CF2YN48CF2 DAL115 CN480 -208Y480 -240 N48LF2YN48LF2D9, 15Y240 -208Y480 -208Y480 -240 N24SF2YN48SF2YN48SF2D8A transformer is a static, passive electrical device that converts alternating electrical voltage from one value to another without modifying the frequency or amount of electrical power.

9 A trans-former links together two or more electrical circuits through the process of electromagnetic induction. A simple transformer consists of two coils of electrical wire wrapped around a common closed magnetic iron circuit (or core ). The coils are electrically isolated from one another but magnetically linked through the core, allow-ing electrical power to be transferred from one coil to the are primarily used to increase ( step-up ) or decrease ( step-down ) voltage from their input ( primary ) to their output ( secondary ). The amount of voltage change is determined by the ratio of the number of turns in the primary coil to the number of turns in the secondary coil.

10 A secondary use of Transformers is to electrically isolate the input from the output circuit while maintain-ing the same input and output Shielded TransformersElectrostatically shielded Transformers are designed to protect primary systems from unwanted high-frequency signals gener-ated by loads connected to a transformer s secondary. While all Transformers with separate primary and secondary windings provide some isolation from load circuits, transients and electrical noise can be transmitted through the internal capacitance of the transformer windings. These disturbances may have a detrimental effect on sensitive electronic equipment and can cause improper operation.