M and F Line - HVAC and Refrigeration Information Links

M and F line SystemPro hermetic air-cooled condensing unitsProduct InformationHorsepower: 1/6 5 Temperature Applications: Low/Medium/HighRefrigerants: R-134a, R- 404a , R-22, R-407 CInstallation Applications: A variety of applications including under-counter coolers, food prep tables, reach-in cases, and walk-in boxesUnit FeaturesFlare BOM (Obsolete)Sweat BOMS uction ConnectionsLiquid ConnectionsFilterDrierSight GlassElectrical ConnectionsFan Cycle ControlFan GuardUL/URSuction ValveSuctionAccumulatorBase ValveReceiver w/ValvePower CordBX Conduit105, 106111 UR109103 UR201212 UR*010015 UL001020 UL072 UL272 UR*These recognized models are identical to listed models less pressure control. Need for the control is to be evaluated in the end use Welded Condensing UnitsTemperature ApplicationCodeHigh TemperatureMedium TemperatureLow TemperatureExtended Medium Low TemperatureMultipleMultipleHMLFESNC ondensing Unit Family SeriesComp.

M and F Line SystemPro® hermetic air-cooled condensing units Product Information Horsepower: 1/6 – 5 Temperature Applications: Low/Medium/High Refrigerants: R-134a, R-404A, R-22, R-407C

Tags:

  404a, Line, M and f line

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of M and F Line - HVAC and Refrigeration Information Links

1 M and F line SystemPro hermetic air-cooled condensing unitsProduct InformationHorsepower: 1/6 5 Temperature Applications: Low/Medium/HighRefrigerants: R-134a, R- 404a , R-22, R-407 CInstallation Applications: A variety of applications including under-counter coolers, food prep tables, reach-in cases, and walk-in boxesUnit FeaturesFlare BOM (Obsolete)Sweat BOMS uction ConnectionsLiquid ConnectionsFilterDrierSight GlassElectrical ConnectionsFan Cycle ControlFan GuardUL/URSuction ValveSuctionAccumulatorBase ValveReceiver w/ValvePower CordBX Conduit105, 106111 UR109103 UR201212 UR*010015 UL001020 UL072 UL272 UR*These recognized models are identical to listed models less pressure control. Need for the control is to be evaluated in the end use Welded Condensing UnitsTemperature ApplicationCodeHigh TemperatureMedium TemperatureLow TemperatureExtended Medium Low TemperatureMultipleMultipleHMLFESNC ondensing Unit Family SeriesComp.

2 Motor RatingNominal HPCode1/23/411-1/2234567-1/2910150050007 5010001500200030004000500060075000900100 01500X X X X - X X X XCompressor Motor TypesPhaseDescriptionCode1 Capacitor Run - Capacitor StartC1 Induction Run - Capacitor StartI1 Induction Run - Split PhaseS1 Capacitor Run - Permanent SplitP3 Three Phase - GeneralT3 Star (Wye) DeltaE36 Lead - Part Winding or Across the LineFCompressor Motor ProtectionType ProtectionCodeExternal Inherent Protection-One Protector ( line Break)AInternal Inherent Protection One Protector ( line Break)FInternal Thermal Protection Electronic Sensors; andControl Module ExternalSBill Of Material (BOM)001 thru 099 Intended for UL Listing and CUL Certifi ed100 thru 299 Intended for UL Rercognition and CUL Certifi ed300 thru 399 Not eligible for either UL Listing, UL Recognition or CUL Certifi ed- X X X - X X XRefrigerantCodeR404A/507J/4R134aT/2R12B R22C/3/MMultipleFR22/407 CGR229R134a/ 404a /22NR134a/404 APR404A/228 Type of DesignCodeAir Cooled Steel BaseAAir Cooled Copevap BaseE/PNarrow Air Cooled Copevap TWater Cooled Steel BaseWCustom BaseCDiscusDElectrical Codes60.

3 When applicable, specifi c 50 Hz ratings (not necessarily identical to typical shown above) will be shown as alternate on 60 Hz rated _M&F (4/11) Emerson Climate TechnologiesNOTE: See appendix for Flex- line hood informationResources and Online Product Information and Technical Data Application Engineering Bulletins Instruction Sheets Marketing Brochures Product Selection Tools Walk-In Box Load Calculator Software Quick Selection Slide Rule Where to BuySystemPro hermetic air-cooled condensing unitsFeatures Benefi ts Copeland Hermetic Compressor and Heavy Duty Unit Bearing Fan MotorReliability High Energy Effi ciency Low Sound & Vibration Modular Components Replacement Serviceability Compact DesignApplication FlexibilityAll Models Rated Up To 110 F AmbientApplication Engineering Bulletins 4-1273 Factors to Consider in Converting Compressor Rated Capacity to Actual Capacity4-1292 Medium Temperature R-22 Copelaweld Compressors4-1295 HFC-134A Refrigerant Guidelines4-1298 Extended

4 Medium Temperature R- 404a /507 Hermetic Compressors and Condensing Units4-1305 SystemPro AF, AR, & AS Refrigeration Hermetic 1/8-1 Horsepower Compressors4-1306 Application Guidelines for RF Low Temperature Refrigeration Compressors4-1307 Application Guidelines for CF Refrigeration Compressors and Condensing Units4-1344 Application Guidelines for RFT, RRT, RST Compressors11-1147 Suction Accumulators17-1260 Compressor Overheating17-1268 Compression Ratio as it Affects Compressor Reliability22-1182 Liquid Refrigerant Control in Refrigeration and Air Conditioning SystemsFor more Information , visit and login to the Customer Portal to view Online Product Information22011DS-4 _M&F (4/11) Emerson Climate TechnologiesNOTE.

5 See appendix for Flex- line hood informationSystemPro air-cooled condensing unitsCapacity DataHIGH/MED TEMPC apacity (BTU/Hr) at 90 Ambient - Evaporator Temp ( F) +10+15+20+25M2FH-0017-SAA111134a1/680091 010301150M2FH-0020-IAA111134a1/595010701 2001330 MMFH-0022-IAA111221/51250138015301680M4F H-0022-IAA111404A1/51340146015901720M2FH -0024-SAA111134a1/41310147016401810M2FH- 0026-IAA072,111,103134a1/415301700189020 80 MCFH-0027-IAA111,103,272221/419102130236 02600M4FH-0025-IAA103,272404A1/418902060 22402430M2FH-A033-IAA, IAV111,103,272134a1/31870211023602620 MCFH-0036-IAA111,103,272221/322702550283 03140M4FH-A036-IAA, IAV111,103,272404A1/32550281030903370M2F H-0049-IAA, IAV111,103,272134a1/22610292032503600 MCFH-0049-CAA, CAV111,103,272221/23090346038404250M2FH- 0050-IAA-IAV111,103,272134a1/22950335037 804230M4FF-0050-IAA, IAV212404A1/228903660398043204660M4FF-00 56-IAA, IAV103,212,272404A1/23140392043304750518 0M2FH-0056-IAA, IAV111,103,272134a1/23240368041404630 MCFH-0056-IAA, IAV111,103,272221/23610402044704950M4FH- 0050-CAA, CAV111,103,272404A1/23320366040104380 FTAH-B074-IAA.

6 IAV212134a3/43890438049005450 FTAM-A075-IAA, IAV020134a3/44260492056506450F3AH-A078-I AA, IAV020223/44480512057606450M4FF-0075-CAA , CAV020404A3/440005010555060906660 FTAH-A101-CFV, TFC, TFD020134a14990586068207770F3AH-A100-CAV 0202215260596067007480 FJAF-0106-CAV020404A15160642070807780850 0F3AM-A105-CFV, TFC0202216530753085309590 FTAH-A125-CFV, TFC, TFD020134a1-1/471708420977011200 FJAM-A125-CFV, TFC020404A1-1/453906840762084509340 FJAM-A126-CAV, TFC020404A1-1/4635079408770964010500 FTAH-A150-CFV, TFC, TFD020134a1-1/2100001160013300 FGAH-A151-CFV, TFC, TFD020221-1/2759088001010011500 FGAH-A151-CFV, TFC, TFD020407C1-1/2547076308770994011200 FJAM-A150-CFV, TFC, TFD020404A1-1/268609100102001140012500 FTAH-A201-CFV, TFC, TFD020134a210300122001420016400 FGAH-A201-CFV, TFC, TFD015, 02022210100118001350015400 FGAH-A201-CFV, TFC, TFD015, 020407C29790113001290014500 FJAM-A200-CFV, TFC020404A2877011600130001450016100 FJAM-A225-CFV, TFC, TFD020404A2-1/41040013400149001640017900 FGAH-A225-CFV, TFC, TFD015, 020222-1/411400131001510017100 FGAH-A225-CFV, TFC, TFD015, 020407C2-1/4811011400132001500016800 FGAH-A301-CFV, TFC, TFD015, 02022317000195002200024600 FGAH-A301-CFV, TFC, TFD015, 020407C31010014900174001990022600 FJAM-A300-CFV, TFC, TFD020404A31310017300195002160023800 FGAH-A325-CFV, TFC, TFD015, 020223-1/418300209002360026500 FGAH-A325-CFV, TFC, TFD015, 020407C3-1/41120016400191002190024800 FJAM-A325-CFV, TFC, TFD020404A3-1/41430018500208002330026100 FGAH-A401-CFV, TFC, TFD015, 02022425900295003340037600 FGAH-A401-CFV, TFC, TFD015, 020407C41550023000269003090035200 FJAM-B400-CFV, TFC, TFD020404A42070026900303003390037800 FGAH-A501-CFV, TFC, TFD, TFE015, 02022529800340003820042700 FGAH-A501-CFV, TFC, TFD, TFE015, 020407C52250030400345003880043200 FJAM-B500-CFV.

7 TFC020404A52320030400341003770041200 Capacities are at 60 Hertz with 5 F subcooling. HT models are rated at 65 F return gas temperature. MT models are rated at 40 F return gas temperature32011DS-4 _M&F (4/11) Emerson Climate TechnologiesNOTE: See appendix for Flex- line hood informationSystemPro air-cooled condensing unitsCapacity DataHIGH/MED TEMPC apacity (BTU/Hr) at 90 Ambient - Evaporator Temp ( F) +30+35+40+45M2FH-0017-SAA111134a1/612801 41015601710M2FH-0020-IAA111134a1/5147016 2017701930 MMFH-0022-IAA111221/51840201021802360M4F H-0022-IAA111404A1/51860201021602310M2FH -0024-SAA111134a1/42000219023902600M2FH- 0026-IAA072,111,103134a1/422802490271029 40 MCFH-0027-IAA111,103,272221/428503110338 03660M4FH-0025-IAA103,272404A1/426202820 30303240M2FH-A033-IAA, IAV111,103,272134a1/32900319035003820 MCFH-0036-IAA111,103,272221/334603790414 04500M4FH-A036-IAA, IAV111,103,272404A1/33670399043104650M2F H-0049-IAA, IAV111,103,272134a1/23960434047405150 MCFH-0049-CAA, CAV111,103,272221/24680513056006090M2FH- 0050-IAA-IAV111,103,272134a1/24710521057 406290M4FF-0050-IAA, IAV212404A1/2M4FF-0056-IAA, IAV103,212,272404A1/2M2FH-0056-IAA, IAV111,103,272134a1/25150569062706870 MCFH-0056-IAA, IAV111,103,272221/25480607067207440M4FH- 0050-CAA, CAV111,103,272404A1/24770518056006040 FTAH-B074-IAA.

8 IAV212134a3/46050671074308220 FTAM-A075-IAA, IAV020134a3/4F3AH-A078-IAA, IAV020223/47130787086609440M4FF-0075-CAA , CAV020404A3/4 FTAH-A101-CFV, TFC, TFD020134a1878097901080011800F3AH-A100-C AV020221832092201020011200 FJAF-0106-CAV020404A1F3AM-A105-CFV, TFC020221 FTAH-A125-CFV, TFC, TFD020134a1-1/412800144001620018000 FJAM-A125-CFV, TFC020404A1-1/4 FJAM-A126-CAV, TFC020404A1-1/4 FTAH-A150-CFV, TFC, TFD020134a1-1/215100170001900021100 FGAH-A151-CFV, TFC, TFD020221-1/213000145001610017700 FGAH-A151-CFV, TFC, TFD020407C1-1/212500138001520016700 FJAM-A150-CFV, TFC, TFD020404A1-1/2 FTAH-A201-CFV, TFC, TFD020134a218800213002400026900 FGAH-A201-CFV, TFC, TFD015, 02022217300194002160023900 FGAH-A201-CFV, TFC, TFD015, 020407C216200180001990021900 FJAM-A200-CFV, TFC020404A2 FJAM-A225-CFV, TFC, TFD020404A2-1/4 FGAH-A225-CFV, TFC, TFD015, 020222-1/419300215002390026400 FGAH-A225-CFV, TFC, TFD015, 020407C2-1/418800208002300025200 FGAH-A301-CFV, TFC, TFD015, 02022327400303003330036500 FGAH-A301-CFV, TFC, TFD015, 020407C325400283003140034700 FJAM-A300-CFV, TFC, TFD020404A3 FGAH-A325-CFV, TFC, TFD015, 020223-1/429400325003590039400 FGAH-A325-CFV, TFC, TFD015, 020407C3-1/427900311003440038000 FJAM-A325-CFV, TFC, TFD020404A3-1/4 FGAH-A401-CFV, TFC, TFD015, 02022441900465005120056200 FGAH-A401-CFV, TFC, TFD015, 020407C439700444004950054800 FJAM-B400-CFV, TFC, TFD020404A4 FGAH-A501-CFV, TFC, TFD, TFE015, 02022547400524005750063000 FGAH-A501-CFV, TFC, TFD, TFE015, 020407C547800526005760062800 FJAM-B500-CFV, TFC020404A5 Capacities are at 60 Hertz with 5 F subcooling.

9 HT models are rated at 65 F return gas temperature. MT models are rated at 40 F return gas temperature42011DS-4 _M&F (4/11) Emerson Climate TechnologiesNOTE: See appendix for Flex- line hood informationSystemPro air-cooled condensing unitsCapacity DataHIGH/MED TEMPC apacity (BTU/Hr) at 100 Ambient - Evaporator Temp ( F) +10+15+20+25M2FH-0017-SAA111134a1/673083 09301050M2FH-0020-IAA111134a1/5890101011 201250 MMFH-0022-IAA111221/51140127014001550M4F H-0022-IAA111404A1/51230134014601590M2FH -0024-SAA111134a1/41230139015301710M2FH- 0026-IAA072,111,103134a1/414001570171018 90 MCFH-0027-IAA111,103,272221/417101930215 02380M4FH-0025-IAA103,272404A1/417001870 20302220M2FH-A033-IAA, IAV111,103,272134a1/31690192021502420 MCFH-0036-IAA111,103,272221/320802330260 02890M4FH-A036-IAA, IAV111,103,272404A1/32330258028403100M2F H-0049-IAA, IAV111,103,272134a1/22410271030203350 MCFH-0049-CAA, CAV111,103,272221/22910326036304010M2FH- 0050-IAA-IAV111,103,272134a1/22730317035 003860M4FF-0050-IAA, IAV212404A1/226603260355038504140M4FF-00 56-IAA, IAV103,212,272404A1/22780349038604240463 0M2FH-0056-IAA, IAV111,103,272134a1/23010343038804220 MCFH-0056-IAA, IAV111,103,272221/23270366040704520M4FH- 0050-CAA, CAV111,103,272404A1/22900322035603910 FTAH-B074-IAA.

10 IAV212134a3/43420387043504860 FTAM-A075-IAA, IAV020134a3/43870443050705780F3AH-A078-I AA, IAV020223/44020462052205860M4FF-0075-CAA , CAV020404A3/435404470496054605980 FTAH-A101-CFV, TFC, TFD020134a14330516060606970F3AH-A100-CAV 0202214740544061406910 FJAF-0106-CAV020404A14650580064107040770 0F3AM-A105-CFV, TFC0202215750670076408650 FTAH-A125-CFV, TFC, TFD020134a1-1/46190736086209970 FJAM-A125-CFV, TFC020404A1-1/447706070675074708250 FJAM-A126-CAV, TFC020404A1-1/456107060781086009420 FTAH-A150-CFV, TFC, TFD020134a1-1/2737087601020011800 FGAH-A151-CFV, TFC, TFD020221-1/264907630885010200 FGAH-A151-CFV, TFC, TFD020407C1-1/2481068607940905010200 FJAM-A150-CFV, TFC, TFD020404A1-1/2578078208850989010900 FTAH-A201-CFV, TFC, TFD020134a28880107001260014600 FGAH-A201-CFV, TFC, TFD015, 0202228930105001220013900 FGAH-A201-CFV, TFC, TFD015, 020407C261108820102001170013300 FJAM-A200-CFV, TFC020404A2750010100114001280014200 FJAM-A225-CFV, TFC, TFD020404A2-1/4906011700131001450015800 FGAH-A225-CFV, TFC, TFD015, 020222-1/410100118001360015500 FGAH-A225-CFV, TFC, TFD015, 020407C2-1/4712010300119001360015400 FGAH-A301-CFV, TFC, TFD015, 0202231510017400199002240025000 FGAH-A301-CFV, TFC, TFD015, 020407C3836012900152001760020100 FJAM-A300-CFV, TFC, TFD020404A31120015000170001890020900 FGAH-A325-CFV, TFC, TFD015, 020223-1/416500190002160024200 FGAH-A325-CFV, TFC, TFD015, 020407C3-1/4916014200167001930022000 FJAM-A325-CFV, TFC, TFD020404A3-1/41220016000181002040022900 FGAH-A401-CFV, TFC, TFD015, 02022423500270003060034500 FGAH-A401-CFV, TFC, TFD015, 020407C41270019900236002750031500 FJAM-B400-CFV, TFC, TFD020404A41810023700268003000033500 FGAH-A501-CFV, TFC, TFD, TFE015, 02022528000321003630040600 FGAH-A501-CFV, TFC, TFD, TFE015, 020407C5276003160