Makes Pensky-Martens, TAG, and Abel Flash Point …

A10841 HFP 360 SERIES 2/18/00 10:09 AM Page 3. Makes pensky -Martens, TAG, and Abel Flash Point Testing Easier Than Ever Interchangeable test modules allow you to run different Tests for samples with unknown Flash points. Built-in fire detection system with audible alarm tests with a single instrument. and external alarm relay contact. Automatically corrects results to standard Preprogrammed with standard laboratory barometric pressure. Thermal Flash Point detection eliminates any Flash Point test procedures: interference from water or silicone containing samples.

Specifications Ordering Information HFP 360 Pensky-Martens Flash Point Analyzer HFP 362 TAG Flash Point Analyzer HFP 364 Abel Flash Point Analyzer Available Test Modules Pensky-Martens, TAG Closed Cup, and Abel

Tags:

  Pensky

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Makes Pensky-Martens, TAG, and Abel Flash Point …

1 A10841 HFP 360 SERIES 2/18/00 10:09 AM Page 3. Makes pensky -Martens, TAG, and Abel Flash Point Testing Easier Than Ever Interchangeable test modules allow you to run different Tests for samples with unknown Flash points. Built-in fire detection system with audible alarm tests with a single instrument. and external alarm relay contact. Automatically corrects results to standard Preprogrammed with standard laboratory barometric pressure. Thermal Flash Point detection eliminates any Flash Point test procedures: interference from water or silicone containing samples.

2 pensky -Martens (ASTM D 93 A & B, Easy-to-use touch screen testing, programming, ISO 2719 A & B, DIN 51758) test methods; diagnostics, and calibration. Optional metal sample temperature probe. TAG Closed Cup (ASTM D 56) test method; Integral results database stores up Built-in gas or electric ignition facilities. Abel (IP 170) test method. to 300 measurements. Stores up to 20 permanent and user-defined Stand-alone or networked operation; permits single test programs. station control over a second Herzog Flash Point tester.

3 A10841 HFP 360 SERIES 2/18/00 10:10 AM Page 4. HFP-Series Automatic Flash Point Analyzers HFP-Series Automatic Flash Point Analyzers are designed Complete and to simplify the testing of hydrocarbon samples using the pensky -Martens or other closed cup test methods. All you Thorough Documentation do is insert the appropriate test module in the instrument Test results are displayed on the HFP's graphics readout and press Start. and can also be output automatically or on demand to In addition to performing standard pensky -Martens an optional companion printer or computer system.

4 A. (ASTM D 93), TAG (ASTM D 56), and Abel (IP 170) typical report includes the Sample ID, Date and Time, testing, this versatile analyzer is easily programmed Measurement Program, User Name, and Test Result. with your own customized test protocols. Test selection To further enhance the instrument's documentation and other operational commands are entered via the capabilities, the results from up to 300 Flash Point tests instrument's easy-to-use touch screen display. The can be stored in its integral database and recalled for system even includes on line help to guide you through statistical analysis.

5 Operational procedures. Flash Point Testing By The Totally Automated Interchangeable test modules enable you to perform pensky -Martens, TAG, and Abel Flash Point tests using a single base instrument. The HFP Flash Point Analyzer is designed to save you time, money, and bench space. Its special interchangeable test modules allow you to switch from one test method to another quickly and easily. Moreover, the HFP. automatically recognizes which test module is installed, so you can begin standard method testing without additional system programming or configuration.

6 The HFP automatically determines Flash Point in strict compliance with the appropriate test method. Heating is microprocessor-controlled at the specified rate; the igniter is activated and dipped at precisely the correct temperature and frequency; and when Flash Point is detected, results are automatically corrected for standard barometric pressure and displayed on a bright, easy-to-read display. The HFP is preprogrammed to perform the following laboratory test procedures: PenskyMartens (ASTM D 93, Methods A ISO 2719.)

7 A DIN 51758), TAG Closed Cup (ASTM D 56), and Abel (IP 170). In addition to the standard test methods, the HFP may be programmed with as many as 19 user-defined test protocols and to test for samples with unknown Flash points. Naturally, password protec- tion is available to prevent inadvertent changing of programmed test parameters. A10841 HFP 360 SERIES 2/18/00 10:10 AM Page 5. The HFP's touch screen . Main Menu Extern Unit display lets you quickly initiate standard Flash Point testing, Parameter change test parameters, run the system diagnostics, and Running Diagnostics recall test results.

8 A Test Messages Results Calibration Database pensky -Martens Flash Point determinations Measuring Program Extern Unit may be run using the standard MP-Name: MP ASTM D93A test method or customized test protocols. Standard Standard: ASTM D93A. methods include Temp. unit: C. pensky -Martens (ASTM D 93, Start test: 23 K. Methods A & B), TAG Closed End of test: 20 K. Cup (ASTM D 56), A non-display Extension Analyzer (available in the Summer of 1999) may be Test interval 1: K. programmed, operated, and controlled from the Main HFP Flash Point Analyzer.

9 And Abel (IP 170). Test interval 2: K. Change temperature: 110 C. Operational Flexibility Menu Save List MP Help Print Ignition HFP-Series Analyzers are available with either a gas or electronic ignition system. Units equipped The HFP Makes it easy to Extern with the electronic ignition system also incorporate a Measurement All Unit view existing test parameters or create customized test special circuit to monitor igniter wear. Sample number : Sample 12. procedures for specific Sample descr. : GAS OIL products. Cooling A built-in ventilator cools the heating block Meas.

10 Program : MP ASTM D93A. to a preprogrammed temperature once Flash Point is detected, making external cooling unnecessary in most Expected FP : 65 C. installations. When required, an optional external User : HERZOG. cooling block is available for the pensky -Martens;. Test status : ready built-in cooling connections are available for the TAG and Abel test modules. Menu Stop View Help Stby Param. off Flash Detection The HFP is equipped with a thermal The HFP automatically detection system to eliminate interference from water or All Extern corrects the measured Flash silicone containing samples.