MANHOLE CASTING REFERENCE GUIDE

MANHOLE CASTINGREFERENCE ..2 Load ..3 Key Dimensions of Round Frame and Cover ..3 Key Dimensions of Inlet Frame and Grate ..4 Frame Designs ..5 Grate Designs ..6 Curb Inlets or Combination Inlets ..7 Watertight Frames and Covers ..8 Airport Castings ..8 MANHOLE Features ..9-10 NATIONAL PRECAST CONCRETE ASSOCIATIONWith nearly 1,000 member companies, NPCA serves as the voice of the precast concrete industry in the United States and Canada. The industry includes a diverse mix of companies, from small single-plant manufacturers to multinational vertically integrated companies that operate in many sectors of the construction industry.

6 Grate Designs QUICK REFERENCE Vane Grate The vane grates allows better hydraulic efficiency. Vane Grate with Cross Bars Vane grates, which have better hydraulic efficiency, are

Tags:

  Guide, Reference, Manholes, Great, Casting, Manhole casting reference guide

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MANHOLE CASTING REFERENCE GUIDE

1 MANHOLE CASTINGREFERENCE ..2 Load ..3 Key Dimensions of Round Frame and Cover ..3 Key Dimensions of Inlet Frame and Grate ..4 Frame Designs ..5 Grate Designs ..6 Curb Inlets or Combination Inlets ..7 Watertight Frames and Covers ..8 Airport Castings ..8 MANHOLE Features ..9-10 NATIONAL PRECAST CONCRETE ASSOCIATIONWith nearly 1,000 member companies, NPCA serves as the voice of the precast concrete industry in the United States and Canada. The industry includes a diverse mix of companies, from small single-plant manufacturers to multinational vertically integrated companies that operate in many sectors of the construction industry.

2 NPCA provides an array of services to these manufacturers that include technical engineering support, the industry s largest certification program, safety programming, educational courses and a suite of print and online publications. In addition to services to members, NPCA provides specialized technical information to owners, contractors, engineers and designers on precast concrete products. Copyright 2012 by National Precast Concrete Association (NPCA); all rights reserved. No part of this manual may be reproduced in any form without permission in writing from the National Precast Concrete City Center Dr.

3 , Suite 200, Carmel, IN 46032 800-366-7731 OF CONTENTSM aterialsQUICK REFERENCEAll the iron provided in a product should have a minimum recycled material content of 85%. All manufacturers should provide material certifications on product that includes country of origin and material quality and if requested, shall provide load test data on the CASTING . Gray Iron Iron conforming to ASTM A48, Class 35B, as noted in section and of AASHTO M306. Class 35B exhibits the best corrosion and wear resistance properties as well as the desirable quality of high compressive strength. Therefore it makes a good load bearing street hardware.

4 35,000 psi minimum tensile strength iron is furnished. Ductile Iron Iron conforming to ASTM A536. Ideal material for construction castings when standard gray iron castings do not have the load bearing capabilities. Ductile Iron has greater strength characteristics than structural carbon steel without the corrosion characteristics of steel. It is usually used in areas subjected to loads greater then H20 loadings. Also because it has excellent compressive strength it is often recommended as a cost effective approach to mate ductile iron lids or grates with gray iron Grates Material shall be hot rolled steel confirming to ASTM A36.

5 Galvanizing is recommended for all steel frame, grates & covers, conforming to ASTM 123. Steel grates can be compatible with cast iron frames. 3 Load BearingQUICK REFERENCEL ight DutyThese castings are suitable for a wide range of non-traffic locations. Castings labeled light duty are recommended for sidewalks, terraces, landscape applications, and very light duty vehicular traffic, such as golf carts or lawn Duty AASHTO M306 Highway LoadingAccording to AASHTO M306 castings must meet a minimum of 40,000 lbs proof load on a 9 x 9 load test area. After the test, the cover grating or frame is inspected for cracks or deformation.

6 This specification allows for a safety factor of QUICK REFERENCEC lear Opening Clear opening is the diameter of the smallest opening located near the top of the frame. It is also known as the C Diameter The cover diameter is the diameter of the lid. It is also known as the A Thickness Cover thickness is the thickness of the lid at the perimeter. It is also known as the B Height The frame height is the height of the frame. It is also known as the F over 16,000 lbs requirement of H20 and HS20. This load designation is appropriate for general traffic applications.

7 Extra Heavy Duty (Airport and Port Authority)Castings listed in this category can accommodate wheel loads of 100 psi or greater. They are considered for airports and any place where concentrated loads might be applied. These castings can also accept proof loads from 100,000 to 200,000 lbs, which meets the design loading associated with the FAA wheel loading. Key Dimensions of Round Frame and CoverBase Flange OpeningBase flange opening is the opening at the bottom of the frame. It is also known as the D flange diameter Frame flange diameter is the diameter of the whole frame or the length from the outermost part of the flange directly across to the other outermost side.

8 It is also known as the E REFERENCEC lear Opening Clear opening is the length of the opening located near the top of the frame. It is also known as the C Diameter The grate diameter is the diameter of the lid. It is also known as the A OpeningThe width of the opening between bars in thegrate. It is also known as the G Thickness Grate thickness is the depth of the grate at the perimeter. It is also known as the B Height The frame height is the height of the frame. It is also known as the F Flange OpeningBase flange opening is the opening at the bottom of the frame.

9 It is also known as the D dimension. Frame Flange Diameter Frame flange diameter is the diameter of the whole frame or the length from the outermost part of the flange directly across to the other outermost side. It is also known as the E dimension. Key Dimensions of Inlet Frame and Grate5 Frame Designs QUICK REFERENCEB ottom & Top Flange A bottom flange is a flange that is located at the base of the frame. A top flange is a flange that is located at the top of the frame, and is typically installed in a concrete slab FlangeA reversible flange can be either on the top or bottom of the frame depending on how the lid is placed on the frame.

10 Top flange is also known as the slab type and the bottom flange is also known as the built up Ring A mud ring is cast into the frame on the bottom below the flange so the frame centers properly on the MANHOLE cone. MANHOLE Frame with Mud Ring6 Grate Designs QUICK REFERENCEVane GrateThe vane grates allows better hydraulic Grate with Cross BarsVane grates, which have better hydraulic efficiency, are angled toward the flow of water. The vane grate offers longitude bars that are friendlier toward Grate The designer must be aware of the ADA requirements before using this EfficiencyThe hydraulic efficiency of a grate is its rated ability to intercept storm water.