Example: bankruptcy

Manual Call Points - wit-dvr.com

call Points7 LSN Manual call Points226 Conventional Manual call Points237 Accessories - Manual call Points LSN andConventional246 Conventional Manual call Points for ExAreas249 Accessories - Manual call Points for Bosch Security Systems | Manual call Points | LSN Manual call PointsFMC 420RW Single ActionCall Points LSN improvedFeatures Alarm triggering by pressing the black marking orbreaking the glass pane Protection against injury through foil-labeled glasspane LED display for triggered alarm or inspectionevaluation Individual call point identification call point query routines with evaluation and multipletransmission Maintains LSN loop functions in the event of wireinterruption or short-circuit thanks to two integratedisolatorsFMC 420RW Single Action call Points are used for manualalarm triggering and can be employed in both the LocalSecurityNetwork (LSN) and the LSN improved action call Points with glass pane:123 Pressing the black marking (1) breaks the glass pane (3),which triggers the alarm and causes the LED display (2) action call Points can be reset with the test key andby replacing the glass pane (3).

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF Manual Call Points 7 LSN Manual Call Points 226 Conventional Manual Call Points

Tags:

  Manual, Call, Points, Manual call points

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Manual Call Points - wit-dvr.com

1 call Points7 LSN Manual call Points226 Conventional Manual call Points237 Accessories - Manual call Points LSN andConventional246 Conventional Manual call Points for ExAreas249 Accessories - Manual call Points for Bosch Security Systems | Manual call Points | LSN Manual call PointsFMC 420RW Single ActionCall Points LSN improvedFeatures Alarm triggering by pressing the black marking orbreaking the glass pane Protection against injury through foil-labeled glasspane LED display for triggered alarm or inspectionevaluation Individual call point identification call point query routines with evaluation and multipletransmission Maintains LSN loop functions in the event of wireinterruption or short-circuit thanks to two integratedisolatorsFMC 420RW Single Action call Points are used for manualalarm triggering and can be employed in both the LocalSecurityNetwork (LSN) and the LSN improved action call Points with glass pane:123 Pressing the black marking (1) breaks the glass pane (3),which triggers the alarm and causes the LED display (2) action call Points can be reset with the test key andby replacing the glass pane (3).

2 The LED display (2) single action call Points :124 Pressing the black marking (1) triggers the alarm. The alarmstatus is displayed by the red window (4) and the flashingLED display (2).Single action call Points can be reset using the test key. TheLED display (2) goes call point identificationNeither single action call Points with glass pane norresettable single action call Points are reset on the call point identification with display of the callpoint address on the fire panel ensures the quick locationof the triggered call and ApprovalsRegionCertificationEuropeCPD078 6-CPD-20333 FMC-420 RWGermanyVdSG 207087 FMC-420 RWInstallation/Configuration Notes Manual call Points must be mounted visibly alongescape and rescue routes ( exits, passageways,stairwells) and be easily accessible. An installation height of 1400 mm 200 mm (55 in. 8in.), measured from the middle of the Manual call pointto the floor, must be maintained.

3 Manual call Points must be sufficiently lit with daylightor another light source (including emergency lighting ifpresent). The maximum number of LSN elements that can beconnected depends on their current consumption fromthe LSN data line. The limit values should be taken fromthe product information supplied with the fire Security Systems call Points | LSN Manual call Points | 227 Standards, guidelines and planning recommendationsregarding the installation location etc. should also betaken into consideration. The regulations of the local fire services must IncludedQuanti-tyComponents1 FMC-420RW-GSGRD Manual call Point with Glass Pane, Surface-mounted, Red1 FMC-420RW-GSRRD Manual call Point Resettable, Surface-mounted, Red1 FMC-420RW-GFGRD Manual call Point with Glass Pane, Flush-mounted, Red1 FMC-420RW-GFRRD Manual call Point Resettable, Flush-mount-ed, Red1 FMC-420RW-GSGYE Manual call Point with Glass Pane, Surface-mounted, Yellow1 FMC-420RW-GSRYE Manual call Point Resettable, Surface-mounted, Yellow1 FMC-420RW-GSGBU Manual call Point with Glass Pane, Surface-mounted, Blue1 FMC-420RW-GSRBU Manual call Point Resettable, Surface-mounted, BlueNoteThe FMC KEY RW Test Key is not included inthe scope of delivery and must be SpecificationsElectricalOperating voltage15 VDC to 33 VDCC urrent mAMechanical componentsDimensions (H x W x D)

4 FMC 420RW GFGRD,FMC 420RW GFRRD107 mm x 107 mm x mm ( x in. x in.) FMC 420RW GSGRD,FMC 420RW GSGBU,FMC 420RW GSGYE87 mm x 87 mm x 56 mm ( in. in. x in.) FMC 420RW GSRRD,FMC 420RW GSRBU,FMC 420RW GSRYE87 mm x 87 mm x 56 mm ( in. in. x in.)Housing materialPlastic, ASAC olors RedRAL 3001 BlueRAL 5005 YellowRAL 1003 Environmental conditionsProtection category according toEN 60529IP 52 Permissible operating temperature-25 C to +70 COrdering InformationFMC 420RW GSGRD Manual call Point withGlass Pane, RedSurface-mountedFMC-420RW-GSGRDFMC 420RW GSRRD Manual call PointResettable, RedSurface-mountedFMC-420RW-GSRRDFMC 420RW GFGRD Manual call Point withGlass Pane, Flush-mounted, RedFlush-mountedFMC-420RW-GFGRDFMC 420RW GFRRD Manual call PointResettable, Flush-mounted, RedFlush-mountedFMC-420RW-GFRRDFMC 420RW GSGYE Manual call Point withGlass Pane, YellowSurface-mountedFMC-420RW-GSGYEFMC 420RW GSRYE Manual call PointResettable, YellowSurface-mountedFMC-420RW-GSRYEFMC 420RW GSGBU Manual call Point withGlass Pane, BlueSurface-mountedFMC-420RW-GSGBUFMC 420RW GSRBU Manual call PointResettable.

5 BlueSurface-mountedFMC-420RW-GSRBUA ccessoriesFMC SPACER RWRD Spacer, RedFor the flush-mounted variant of the RW callpoints. Its use increases the storage room forthe unit = 5 spacersFMC-SPACER-RWRDFMC SPGL RW Spare GlassesSpare glasses for all RW call unit = 5 spare glassesFMC-SPGL-RWFMC SIGN RW Out of Order SignUsed instead of the glass pane when a call pointis not ready for unit = 5 signsFMC-SIGN-RWFMC KEY RW Test KeyThe key can open, check, and reset Manual unit = 1 keyFMC-KEY-RWFMC FLAP RW Clear Hinged FlapTo protect against accidental triggering; unit = 5 Bosch Security Systems | Manual call Points | LSN Manual call PointsFMC-420RW Single Action call Points LSN improved version FMC-420RW-GSGRDFMC-420RW-GSRRDFMC-420RW- GFGRDFMC-420RW-GFRRDD esignwith glass paneresettablewith glass paneresettableRange of useindoorindoorindoorindoorMountingsurfa ce-mountedsurface-mountedflush-mountedfl ush-mountedOperating voltage15 V DC.

6 33 V DC15 V DC .. 33 V DC15 V DC .. 33 V DC15 V DC .. 33 V DCCurrent mAProtection categoryIP 52IP 52IP 52IP 52 Permissible operating tem-perature-25 C .. +70 C-25 C .. +70 C-25 C .. +70 C-25 C .. +70 CColorred, RAL 3001red, RAL 3001red, RAL 3001red, RAL 3001 Bosch Security Systems call Points | LSN Manual call Points | 229 FMC-420RW Single Action call Points LSN improved version FMC-420RW-GSGYEFMC-420RW-GSRYEFMC-420RW- GSGBUFMC-420RW-GSRBUD esignwith glass paneresettablewith glass paneresettableRange of useindoorindoorindoorindoorMountingsurfa ce-mountedsurface-mountedsurface-mounted surface-mountedOperating voltage15 V DC .. 33 V DC15 V DC .. 33 V DC15 V DC .. 33 V DC15 V DC .. 33 V DCCurrent mAProtection categoryIP 52IP 52IP 52IP 52 Permissible operating tem-perature-25 C .. +70 C-25 C .. +70 C-25 C .. +70 C-25 C .. +70 CColoryellow, RAL 1003yellow, RAL 1003blue, RAL 5005blue, RAL Bosch Security Systems | Manual call Points | LSN Manual call PointsFMC 210 DM Manual CallPointsFeatures Adjustment of the Manual call Point after alarmtriggering Automatic or Manual detector addressing via rotaryswitch possible Indicator LED for alarm or for inspection evaluation call point query routines with evaluation and multipletransmission Individual call point identification Maintains LSN loop functions in the event of wireinterruption or short-circuit thanks to two integratedisolatorsThe FMC 210 DM Manual call Points are used to trigger thealarm manually, and are deployed in the LocalSecurityNetwork LSN and LSN improved.

7 Form H ManualCall Points are designed for outdoor deployment, form GManual call Points are designed for indoor the event of an alarm, the glass pane (2) is broken first,then the Manual call point (3) is pressed hard. This activatesthe microswitch for alarm triggering and the indicator LED(4) blinks. A mechanism holds the pressed call point Manual call point can be reset with the reset lever (5)or by closing the door of the Manual call point (1). Theindicator LED (4) goes does not reset the alarm on the fire call point identification with display of the callpoint address on the fire panel ensures the quick locationof the triggered call designs of the Manual call Points for outdoor and indooruse are identical. The Manual call Points for indoor use(form G) are available in red, blue, and yellow; the manualcall Points for outdoor use (form H) are available in red H Manual call Points are equipped with an especiallyresistant PC board layered with LSN featuresThe Manual call Points offer all the features of the improvedLSN technology.

8 Flexible network structures, including "T-tapping"without additional elements Up to 254 LSN improved elements per loop or stub line Automatic or Manual detector addressing selectable viarotary switch, in each case with or without auto-detection Power supply for connected elements via LSN bus up to300 mA Shielded and unshielded cables can be used Cable length up to 1000 m Downwards compatibility to existing LSN systems andcontrol and ApprovalsRegionCertificationEuropeCEFMC- 210-DM-G-B / -H-B / -SM-G-BFMC-210-DM-G-R / -H-R / -SM-G-RFMC-210-DM-G-Y / EST-G-BCPD0786-CPD-20293 FMC-210-DM-G/H-R0786-CPD-20244 FMC-210-DM-G-Y0786-CPD-20245 FMC-210-EST-G-BGermanyVdSG 206100 FMC-210-EST-G-BG 206098 FMC-210-DM-G-R /-G-R-A/ -H-RG 206099 FMC-210-DM-G-YPolandCNBOP0082/2008 FMC-210 DM-G-R, FMC-210DM-H-RCzechRepublicTZ S080_12987 FMC-210 Bosch Security Systems call Points | LSN Manual call Points | 231 RegionCertificationRussiaGOSTPOCC SK08-ZSV-0071 FMC-210-DM,FMC-210-ESTType NumberComplies withFMC 210 DM G REN 54-11:2001/A1:2005, EN 54-17:2005 FMC 210 DM H REN 54-11:2001/A1:2005, EN 54-17:2005 FMC 210 DM G YEN 12094-3:2003, EN 54-17:2005 FMC 210 EST G BEN 12094-3:2003, EN 54-17:2005 Installation/Configuration Notes Manual call Points must be mounted visibly alongescape and rescue routes ( exits, passageways,stairwells) and be easily accessible.

9 An installation height of 1400 mm 200 mm, measuredfrom the middle of the Manual call point to the floor,must be maintained. Manual call Points must be adequately illuminated bysunlight or another light source (including emergencylighting if present). The maximum number of LSN elements that may beconnected depends on their current consumption fromthe LSN data line. The limit values should be taken fromthe product information supplied with the fire panelused. Additional norms, guidelines, and planningrecommendations with respect to installation location,etc. must be taken into account (see fire detectormanual). The regulations of the local fire services must The cable duct can be surface-mounted or flush-mounted. Installation in fire hose cabinets is possible in threeways:135 mm140 mm2,5 mm2 mm139 mm123149,5 mm12,5 depth version 1: ca. 40 mm2 Installation depth version 2: 14 mm3 Installation depth version 3: min.

10 30 mmParts IncludedType NumberComponentFMC 210 DM G RForm G, RedManual call Point for indoor use, indirect triggering(type B), housing color redFMC 210 DM H RForm H, RedManual call Point for outdoor use, indirect triggering(type B) , housing color redFMC 210 DM G BForm G, BlueManual call Point for indoor use, indirect triggering(type B), housing color blueFMC 210 DM H BForm H, BlueManual call Point for outdoor use, indirect triggering(type B), housing color blueFMC 210 DM G YForm G, YellowManual call Point for indoor use, indirect triggering(type B), housing color yellowFMC 210 EST G BForm G, BlueElectronic Stop Device for indoor use, indirect trig-gering (type B), housing color blueNoteThe key must be ordered Bosch Security Systems | Manual call Points | LSN Manual call PointsTechnical SpecificationsElectricalOperating voltage24 V DC (15 V DC .. 33 V DC)Current mAMechanicsDimensions (W x H x D)135 x 135 x 40 mm x x materialPlastic, ASAC olorsRed, RAL 3001 Blue, RAL 5005 Yellow, RAL 1003 WeightApprox.


Related search queries