Example: quiz answers

Mapes Insulated Panels '1999 Mapes Industries, Inc. METAL ...

07420 1 - Mapes Insulated Panels 1999 Mapes Industries, WINDOW PANELSPART 1 - The Panels required are as manufactured by Mapes Industries, Lincoln, NE. Panels consist ofmetal skins laminated to stabilizer substrates with an insulating core material. Panels aredesigned to be glazed into a window system or curtain wall WorkA. Section 05100 Structural SteelB. Section 06100 Back Up WallsC. Section 07200 InsulationD. Section 07600 METAL FlashingE. Section 07920 CaulkingF. Section 08500 WindowsG. Section 08900 Storefront/Curtain WallH. Section 09200 Interior Wall Quality Panel manufacturer shall have a minimum of 25 years Field measurements shall be taken prior to completion of manufacturing and Maximum deviation from vertical and horizontal alignment of installed Panels is 1/8" (3mm)in 20' (6m) Porcelain Enamel Institute ( )A- ASTM-C-282- Spot AcidB- ASTM-C-283- Boiling AcidC- ASTM-C-703- Antimonium Chloride Spall TestD- ASTM-C-346- Gloss RetentionE- ASTM-C-486- Spall ResistanceF- Brunnel Hardness - Aluminum AssociationA- AA-C22-A41: Anodized ClearB- AA-C22-A42: Integral Color American Architectural Manufacturers Association (AAMA)A- Pigmented Organic Coatings on Aluminum - (Polyester)B- High Performance Organic Coatings on Aluminum - (Kynar) American Society of Testing Materials (ASTM)A- E330-84: Structural Performance of Exterior Windows, Curtain Walls and Doorsunder the influ

07420 General.doc - 1 - Mapes Insulated Panels '1999 Mapes Industries, Inc. METAL WINDOW PANELS PART 1 - GENERAL 1.01 Scope 1.01.1 The Panels required are as manufactured by Mapes Industries, Lincoln, NE.

Tags:

  Industreis, Panels, 1999, Insulated, Epma, Mapes insulated panels 1999 mapes industries

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Mapes Insulated Panels '1999 Mapes Industries, Inc. METAL ...

1 07420 1 - Mapes Insulated Panels 1999 Mapes Industries, WINDOW PANELSPART 1 - The Panels required are as manufactured by Mapes Industries, Lincoln, NE. Panels consist ofmetal skins laminated to stabilizer substrates with an insulating core material. Panels aredesigned to be glazed into a window system or curtain wall WorkA. Section 05100 Structural SteelB. Section 06100 Back Up WallsC. Section 07200 InsulationD. Section 07600 METAL FlashingE. Section 07920 CaulkingF. Section 08500 WindowsG. Section 08900 Storefront/Curtain WallH. Section 09200 Interior Wall Quality Panel manufacturer shall have a minimum of 25 years Field measurements shall be taken prior to completion of manufacturing and Maximum deviation from vertical and horizontal alignment of installed Panels is 1/8" (3mm)in 20' (6m) Porcelain Enamel Institute ( )A- ASTM-C-282- Spot AcidB- ASTM-C-283- Boiling AcidC- ASTM-C-703- Antimonium Chloride Spall TestD- ASTM-C-346- Gloss RetentionE- ASTM-C-486- Spall ResistanceF- Brunnel Hardness - Aluminum AssociationA- AA-C22-A41: Anodized ClearB- AA-C22-A42: Integral Color American Architectural Manufacturers Association (AAMA)A- Pigmented Organic Coatings on Aluminum - (Polyester)B- High Performance Organic Coatings on Aluminum - (Kynar) American Society of Testing Materials (ASTM)A- E330-84: Structural Performance of Exterior Windows, Curtain Walls and Doorsunder the influence of wind D1781-76: Climbing Drum Peel Test for D3363-74.

2 Method for Film Hardness by Pencil D2794-90: Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact)E- D3359-90: Method for Measuring Adhesion by the tape 2 The materials and products specified in this section establish a minimum standard of requiredfunction, design, appearance quality and warranty to be met by any proposed No substitutions will be considered unless a written request for approval has been submittedby the bidder and received by the architect 10 days prior to the bid Submittals shall be in conformance with section ____. Included section number of Divisionand refer to CSI Division I, Section 1340 - Shop Drawings, Product Data and Samples: A: Panel makeup - 2 samples - 10"x10" B: Two samples of each color and finish texture - 3"x5" Submission Drawings: Indicate thickness, dimension and components of parts. Detail glazingmethods, framing and tolerances to accommodate thermal Affidavit certifying materials meet all requirements as 2 copies of manufacturers standard literature for specified , Storage and Protect finish and edge in accordance with panel manufacturer's Store materials in accordance with panel manufacturer's 2 - Panels - Laminated METAL faced Panels as manufactured by Mapes Industries, Acceptable alternatives: Panels having similar composite construction and finish providingmanufacturer has a minimum of 25 years panel laminating experience and comparablepublished Manufacturer shall produce the porcelain skin and laminate the panel in the same controlledmanufacturing A: Porcelain on Aluminum (Embossed)B: Porcelain on Steel (Smooth)C: Kynar/Hylar - AAMA resin based - 70%D: Anodized Clear, Light, Medium, Dark Bronze and Black - Class I and IIE.

3 Polyester - AAMA - Color as specified from manufacturer's Panel Composition: Two sheets of aluminum bonded to stabilizer substrates with a insulative 3 Substrates: A: High density tempered hardboardB: Fiber reinforced cement boardC: Fire code gypsum (Internal Only)D: High-density polyethylene (HDPE) :A: 2-lb density polystyreneB: density IsocyanurateC: Expanded Aluminum Faces - Thickness range - .012 - . Tolerances - .8% of Panels dimension length and width - 1/16" Panel Weight Range - 1/4"- to "- to Panel Thickness - As required - Range 1/4" to 4 1/4" Recommended for use as an infill panel component in window and curtain wall material to complete installation as recommended by the against moisture intrusion as recommended by the manufacturer. Polyurethane andsilicone based sealant with a 20 year life are 3 - Panel surfaces shall be free from defects prior to Erect Panels plumb, level and Glaze Panels securely and in accordance with approved shop drawings and manufacturersinstructions to allow for necessary thermal movement and structural Do not install Panels that are observed to be defective including warped, bowed, dented,scratched and delaminating Weatherseal all joints as required using methods and materials as previously Separate dissimilar metals using gasketed fasteners and blocking to eliminate the possibility ofelectrolytic Adjusting and Remove masking film as soon as possible after installation.

4 Masking intentionally left in placeafter panel installation will be the responsibility of the holes and drainage channels must be unobstructed and free from dirt and sealant.


Related search queries