Example: dental hygienist

MASTERFLOW ®®®® 830 - groutspecialist.com.au

MASTERFLOW 830. cementitious high strength non- shrink precision grout DESCRIPTION PERFORMANCE DATA. MASTERFLOW 830 is a non shrink precision grout Strength Strength Development formulated to provide ample working time when mixed and The strength of the grout is often the determining factor in placed at flowable consistency. It contains specially graded deciding when loads can be put on structural members or natural aggregate and provides high early and ultimate machinery. The strength of the grout is dependent on the compressive strengths. MASTERFLOW 830 is normally amount of mixing water used, ambient and substrate placed at a flowable consistency to completely fill voids temperature, curing and age of the hardened grout .

MASTERFLOW ®®®® 830 Cementitious high strength non-shrink precision grout DESCRIPTIONDESCRIPTION MASTERFLOWMASTERFLOW 830 830 830 is a non shrink precision grout

Tags:

  Grout, Shrink, Cementitious, Masterflow, 174 308, Non shrink, 174 830 cementitious

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MASTERFLOW ®®®® 830 - groutspecialist.com.au

1 MASTERFLOW 830. cementitious high strength non- shrink precision grout DESCRIPTION PERFORMANCE DATA. MASTERFLOW 830 is a non shrink precision grout Strength Strength Development formulated to provide ample working time when mixed and The strength of the grout is often the determining factor in placed at flowable consistency. It contains specially graded deciding when loads can be put on structural members or natural aggregate and provides high early and ultimate machinery. The strength of the grout is dependent on the compressive strengths. MASTERFLOW 830 is normally amount of mixing water used, ambient and substrate placed at a flowable consistency to completely fill voids temperature, curing and age of the hardened grout .

2 Between 10mm and 100mm. Thicknesses greater than Typical rate of strength development when placed at 100mm are possible with the addition of aggregate. flowable' consistency at 23 C. RECOMMENDED FOR Age at Test Compressive Strength All precision, non- shrink grouting applications with 1 day 25 MPa clearances of 10mm or more including: 3 days 42 MPa Critical equipment baseplates, soleplates and 7 days 55 MPa columns. 28 days 65 MPa Precast wall panels, beams, columns, structural Test Method: Appendix A. building members and curtain walls. For applications requiring higher compressive strength, Patching poured in place concrete structures refer to MASTERFLOW 870, 870 , MASTERFLOW 880 or honeycombing, using preplaced aggregate BASF Construction Chemicals range of epoxy grouts.

3 Techniques. Underpinning. Flow Retention Anchoring dowels, bolts and other fixings. Flow retention when placed at flowable' consistency at Applications requiring high early compressive 23 C. strengths and high ultimate compressive strengths. Age at Test Flow Retention FEATURES AND BENEFITS Initial 47cm 100%. High strength - provides good early and ultimate After 30 minutes 35cm 90%. strengths which ensure quick return to service and long After 1 hour 24cm 75%. term durability Test Method: Appendix D. non shrink - hardens free of bleeding, settlement and drying shrinkage when placed at flowable consistency Bleeding, Plastic Density and Setting Time Flowable consistency - ensures complete filling of Plastic properties when placed at flowable' consistency.

4 Even intricate voids often without the need for pumping Setting Time Plastic and strapping Bleeding Temp. Density Ample working time - remains placeable up to 1 (%) Initial Initia l Final (kg/m )3. (hr:min) (hr:min). hour - even at high ambient temperatures Dense, impermeable grout - provides a good 23 C 0 2145 4:40 6:00. watertight seal Test Method: Bleeding: Non staining - free of metallic aggregate, similar in Plastic density: appearance to plain concrete. Setting time: Economical - greater volumes of grout can be mixed Volume Change and handled with less labour. Volume change when placed at flowable' consistency at Easy to use - requires no special mixing equipment, it 23 C.

5 Can be mixed in a standard concrete mixer or in a pail Age at Test Volume Change using a grout stirrer. No added chloride. 1 day Positive Strict quality control - ensures reliable and consistent 3 days Positive product performance. 7 days Positive Provides complete non shrink performance- performance- when 28 days Positive tested in accordance with simulated Bedplate Test Method: ASTM C1090 (CRD-C621). Technique. NOTE: The data shown is based on controlled laboratory Compliance with codes - Meets the non- shrink tests. Reasonable variations from the results shown can requirements of ASTM C1090 and CRD-C 621, Corps be expected. Field and laboratory tests should be of Engineers Specification for non shrink grout ; tested conducted on the basis of the desired placing consistency to the requirements of Methods of rather than strictly on indicated water demand.

6 If the sampling and testing admixtures for concrete, mortar and grout . MASTERFLOW 830. project requires that strength tests be made on site do not APPLICATION. use cylinder moulds. Compressive strength should be determined in 50mm cube moulds fitted with compression For application directions on preparation, forming, mixing, cover plates in accordance with AS Appendix A. placing and curing MASTERFLOW 830, 830 as well as the precautions to take in hot and cold weather, refer to VOC content: 3g/L Test method: SCAQMD 304-91 Application Guide for MASTERFLOW cementitious ESTIMATING DATA Precision Grouts available from your local BASF.

7 Construction Chemicals Technical Sales Representative. 20kg of MASTERFLOW 830 mixed to flowable'. For situations requiring dry pack' (damp pack). consistency produces approximately litres ( cubic application, refer to MASTERFLOW 95 or metres) of grout . MASTERFLOW 500. 500. Water Demand SHELF LIFE. Actual amount of water required will depend on desired consistency for the job and temperature (both ambient and MASTERFLOW 830 has a shelf life of approximately 12. grout ). months when stored in a cool dry environment. For any given consistency more water will be required at PACKAGING. high temperatures, and less at low temperatures.

8 MASTERFLOW 830 is packaged in 20kg bags. MASTERFLOW 830 is designed to be placed at a PRECAUTIONS. flowable' consistency which will give 45-50cm lateral flow in the flow trough ( Appendix D). MASTERFLOW 830 is not toxic, but contains Portland As a guide, 20kg of MASTERFLOW 830 mixed at 23 C cement. It has an alkaline nature and thus can be irritating requires approximately litres of water to provide the to skin and eyes. Wear simple dust masks and gloves recommended lateral flow when using a tilting barrel or when handling. Wash off splashes of grout with clean paddle type mixer. When using a grout stirrer, this water water. If irritation persists, seek medical advice.

9 Demand will be slightly increased. For the full health and safety hazard information and how DO NOT USE WATER IN AN AMOUNT OR AT A to safely handle and use this product, please make sure TEMPERATURE THAT WILL CAUSE THE MIXED that you obtain a copy of the BASF Construction grout TO BLEED OR SEGREGATE. Chemicals Material Safety Data Sheet (MSDS). (MSDS from our office or our website. AMf830/1. Mf830/17. /17/1011. The technical information and application advice given in this BASF publication are based on the present state of our best scientific and practical knowledge. As the information herein is of a general nature, no STATEMENT OF.)

10 Assumption can be made as to a product's suitability for a particular use or application and no warranty as to RESPONSIBILITY its accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user is responsible for checking the suitability of products for their intended use. Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor NOTE. since they, and not BASF, BASF are responsible for carrying out procedures appropriate to a specific application.