Transcription of Material Safety Data Sheet - RSU #34
1 Material Safety DataSheet! SECTION 1 PRODUCT AND COMPANY IDENTIFICATIONJohn Deere Hy-Gard Low Vis Transmission/Hydraulic OilProduct Use: Transmission Fluid, Hydraulic OilProduct Number(s): CPS240216 Company IdentificationChevron Products CompanyGlobal Lubricants6001 Bellinger Canyon Ramon, CA 94583 United States of Emergency ResponseCHEMTREC: (800) 424-9300 or (703) 527-3887 Health EmergencyChevron Emergency Information Center: Located in the USA. International collect calls accepted.(800) 231-0623 or (510) 231-0623 Product Informationemail: SECTION 2 COMPOSITION/ INFORMATION ON INGREDIENTS| COMPONENTS CAS NUMBER j AMOUNT| Highly refined mineral oil (C15- C50) ; Mixture ; 80 -100 %weighti Zinc alkyl dithiophosphate j 68649-42-3 i 1 - 5 %weight| SECTION 3 HAZARDS IDENTIFICATIONIMMEDIATE HEALTH EFFECTSEye: Not expected to cause prolonged or significant eye : Contact with the skin is not expected to cause prolonged or significant irritation.
2 Notexpected to be harmful to internal organs if absorbed through the skin. High-Pressure EquipmentInformation: Accidental high-velocity injection under the skin of materials of this type may result inserious injury. Seek medical attention at once should an accident like this occur. The initial woundat the injection site may not appear to be serious at first; but, if left untreated, could result indisfigurement or amputation of the affected : Not expected to be harmful if : Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. Maycause respiratory irritation or other pulmonary effects following prolonged or repeated inhalationof oil mist at airborne levels above the recommended mineral oil mist exposure limit.
3 Symptomsof respiratory irritation may include coughing and difficulty 4 FIRST AID MEASURESEye: No specific first aid measures are required. As a precaution, remove contact lenses, if worn,and flush eyes with : No specific first aid measures are required. As a precaution, remove clothing and shoes ifcontaminated. To remove the Material from skin, use soap and water. Discard contaminatedclothing and shoes or thoroughly clean before : No specific first aid measures are required. Do not induce vomiting. As a precaution,get medical : No specific first aid measures are required. If exposed to excessive levels of materialin the air, move the exposed person to fresh air. Get medical attention if coughing or respiratorydiscomfort to Physicians: In an accident involving high-pressure equipment, this product may beinjected under the skin.
4 Such an accident may result in a small, sometimes bloodless, puncturewound. However, because of its driving force, Material injected into a fingertip can be depositedinto the palm of the hand. Within 24 hours, there is usually a great deal of swelling, discoloration,and intense throbbing pain. Immediate treatment at a surgical emergency center SECTION 5 FIRE FIGHTING MEASURESIL eaks/ruptures in high pressure system using materials of this type can create a fire hazard whenin the vicinity of ignition sources (eg. open flame, pilot lights, sparks, or electric arcs).FIRE CLASSIFICATION:OSHA Classification (29 CFR ): Not classified by OSHA as flammable or RATINGS: Health: 0 Flammability: 1 Reactivity: 0 FLAMMABLE PROPERTIES:Flashpoint: (Cleveland Open Cup) 150 C (302 F) (Min)Autoignition: No data AvailableFlammability (Explosive) Limits (% by volume in air): Lower: Not Applicable Upper: NotApplicableEXTINGUISHING MEDIA: Use water fog, foam, dry chemical or carbon dioxide (CO2) toextinguish OF FIRE FIGHTERS:Fire Fighting Instructions: This Material will burn although it is not easily ignited.
5 For firesinvolving this Material , do not enter any enclosed or confined fire space without proper protectiveequipment, including self-contained breathing Products: Highly dependent on combustion conditions. A complex mixture ofairborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentifiedorganic compounds will be evolved when this Material undergoes 6 ACCIDENTAL RELEASE MEASURESP rotective Measures: Eliminate all sources of ignition in vicinity of spilled Management: Stop the source of the release if you can do it without risk. Contain release toprevent further contamination of soil, surface water or groundwater. Clean up spill as soon aspoociblo, obeorving procautionc in Exposure Controls/Personal Protection.
6 Use appropriatetechniques such as applying non-combustible absorbent materials or pumping. Where feasibleand appropriate, remove contaminated soil. Place contaminated materials in disposablecontainers and dispose of in a manner consistent with applicable : Report spills to local authorities and/or the Coast Guard's National ResponseCenter at (800) 424-8802 as appropriate or required.| SECTION 7 HANDLING AND STORAGEP recautionary Measures: DO NOflames, sparks and hot surfaces. Use only in well ventilated areas. Keep container out of the reach of Handling Information: Avoid contaminating soil or releasing this Material into sewageand drainage systems and bodies of Hazard: Electrostatic charge may accumulate and create a hazardous condition whenhandling this Material .
7 To minimize this hazard, bonding and grounding may be necessary butmay not, by themselves, be sufficient. Review all operations which have the potential ofgenerating and accumulating an electrostatic charge and/or a flammable atmosphere (includingtank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering,mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures. Formore information, refer to OSHA Standard 29 CFR , 'Flammable and CombustibleLiquids', National Fire Protection Association (NFPA 77, 'Recommended Practice on StaticElectricity', and/or the American Petroleum Institute (API) Recommended Practice 2003,'Protection Against Ignitions Arising Out of Static, Lightning, and Stray Currents'.)
8 Container Warnings: Container is not designed to contain pressure. Do not use pressure toempty container or it may rupture with explosive force. Empty containers retain product residue(solid, liquid, and/or vapor) and can be dangerous. Do not pressurize, cut, weld, braze, solder,drill, grind, or expose such containers to heat, flame, sparks, static electricity, or other sources ofignition. They may explode and cause injury or death. Empty containers should be completelydrained, properly closed, and promptly returned to a drum reconditioner or disposed of 8 EXPOSURE CONTROLS/PERSONAL PROTECTIONGENERAL CONSIDERATIONS:Consider the potential hazards of this Material (see Section 3), applicable exposure limits, jobactivities, and other substances in the work place when designing engineering controls andselecting personal protective equipment.
9 If engineering controls or work practices are notadequate to prevent exposure to harmful levels of this Material , the personal protectiveequipment listed below is recommended. The user should read and understand all instructionsand limitations supplied with the equipment since protection is usually provided for a limited timeor under certain CONTROLS:Use in a well-ventilated PROTECTIVE EQUIPMENTEye/Face Protection: No special eye protection is normally required. Where splashing ispossible, wear Safety glasses with side shields as a good Safety Protection: No special protective clothing is normally required. Where splashing is possible,select protective clothing depending on operations conducted, physical requirements and othersubstances in the workplace.
10 Suggested materials for protective gloves include: Nitrile Rubber,Silver Shield, Protection: No respiratory protection is normally user operations generate an oil mist, determine if airborne concentrations are below theoccupational exposure limit for mineral oil mist. If not, wear an approved respirator that providesadequate protection from the measured concentrations of this Material . For air-purifyingrespirators use a particulate a positive pressure air-supplying respirator in circumstances where air-purifying respiratorsmay not provide adequate Exposure Limits:[Component [Agency TWA STEL Ceiling iNotation(Highly refined mineral oil (C15- ACGIH 5 mg/m3.))]]