Call StormTech at or or visit our website at for technical and product MC- 3500 ChamberMC- 3500 & MC- 4500 Design ManualTHE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS StormTech Chamber Systems for Stormwater ManagementCall StormTech at or or visit our website at for technical and product of Product Information .. Foundation for Required Materials/Row Separation .. Cumulative Storage System Structural Cross Sections and General Inspection and Maintenance ..25*For SC-160LP, SC-310, SC-740 & DC-780 designs, please refer to the SC-160LP/SC-310/SC-740/DC-780 Design Engineering Services assists Design professionals in specifying StormTech stormwater systems.

Call StormTech at 860.529.8188 or 888.892.264 or visit our website at www.stormtech.com for technical and product information. 1 StormTech MC-3500 Chamber MC-3500 & MC-4500 . Design Manual. THE MOST . ADVANCED . NAME IN WATER MANAGEMENT SOLUTIONS ™ StormTech ® Chamber Systems for Stormwater Management

Tags:

  Manual, Design, 3500, 4500, Design manual, 3500 amp mc 4500 design manual, 3500 amp mc 4500

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MC-3500 & MC-4500 Design Manual - StormTech

1 Call StormTech at or or visit our website at for technical and product MC- 3500 ChamberMC- 3500 & MC- 4500 Design ManualTHE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS StormTech Chamber Systems for Stormwater ManagementCall StormTech at or or visit our website at for technical and product of Product Information .. Foundation for Required Materials/Row Separation .. Cumulative Storage System Structural Cross Sections and General Inspection and Maintenance ..25*For SC-160LP, SC-310, SC-740 & DC-780 designs, please refer to the SC-160LP/SC-310/SC-740/DC-780 Design Engineering Services assists Design professionals in specifying StormTech stormwater systems.

2 This assistance includes the layout of chambers to meet the engineer s volume requirements and the connections to and from the chambers. They can also assist converting and cost engineering projects currently specified with ponds, pipe, concrete vaults and other manufactured stormwater detention/retention products. Please note that it is the responsibility of the site Design engineer to ensure that the chamber bed layout meets all Design requirements and is in compliance with applicable laws and regulations governing a Manual is exclusively intended to assist engineers in the Design of subsurface stormwater systems using StormTech :PROJECT #:DRAWN:CHECKED:THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE Design ENGINEER OR OTHER PROJECT REPRESENTATIVE.

3 THE SITE Design ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATERESPONSIBILITY OF THE SITE Design ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT TRUEMAN BLVDHILLIARD, OH 43026 ADVANCED DRAINAGE SYSTEMS, MC- 3500 CHAMBERREVDWNCKDDESCRIPTIONEXAMPLE LAYOUT0015'30'860-529-8188 |888-892-2694 | Retention Water QualityNOTES MANIFOLD SIZE TO BE DETERMINED BY SITE Design ENGINEER. SEE TECH SHEET #7 FOR MANIFOLD SIZING GUIDANCE. DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND Design CONSTRAINTS, IT MAY BENECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLD COMPONENTS IN THE FIELD.

4 THE SITE Design ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBERCOVER REQUIREMENTS ARE ROW18" X 18" ADS N-12 TOP MANIFOLDINVERT " ABOVE CHAMBER BASE(SEE NOTES)6" ADS N-12 DUAL WALL PERFORATED HDPE UNDERDRAIN(SIZE TBD BY ENGINEER)INSPECTION PORTPROPOSED STRUCTURE W/ELEVATED BYPASSMANIFOLD MAXIMUM INLET FLOW CFS( Design BY ENGINEER / PROVIDED BY OTHERS)PROPOSED OUTLET CONTROL STRUCTUREMAXIMUM OUTLET FLOW CFS( Design BY ENGINEER / PROVIDED BY OTHERS)PROPOSED LAYOUT60 StormTech MC- 3500 CHAMBERS12 StormTech MC- 3500 END CAPS12 STONE ABOVE (in)9 STONE BELOW (in)40% STONE VOID12,371 INSTALLED SYSTEM VOLUME (CF)(PERIMETER STONE INCLUDED)3,775 SYSTEM AREA (ft )282 SYSTEM PERIMETER (ft)PROPOSED ELEVATIONSMAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED) ALLOWABLE GRADE (UNPAVED WITH TRAFFIC) ALLOWABLE GRADE (UNPAVED NO TRAFFIC) ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT) ALLOWABLE GRADE (TOP OF RIGID PAVEMENT)

5 OF OF MC- 3500 " TOP MANIFOLD " BOTTOM CONNECTION " ISOLATOR ROW " BOTTOM MANIFOLD OF MC- 3500 OF MINIMUM ' OF ADS GEOSYNTHETICS315 WTM WOVEN GEOTEXTILE OVER BEDDINGSTONE AND UNDERNEATH CHAMBER FEET FORSCOUR PROTECTION AT ALL CHAMBER INLET ROWS18" CORED END CAP, PART# MC3500 IEPP18 TCTYP OF ALL MC- 3500 18" TOP CONNECTIONS18" CORED END CAP, PART# MC3500 IEPP18 BCTYP OF ALL MC- 3500 18" BOTTOM CONNECTIONS24" CORED END CAP, PART# MC3500 IEPP24 BCTYP OF ALL MC- 3500 24" BOTTOM CONNECTIONSAND ISOLATOR ROWS18" X 18" ADS N-12 BOTTOM MANIFOLDINVERT " ABOVE CHAMBER BASE(SEE NOTES)24" ADS N-12 BOTTOM CONNECTIONINVERT " ABOVE CHAMBER BASE(SEE NOTES) ' ' ' ' ' ' ' 'Call StormTech at or or visit our website at for technical and product MC- 3500 ChamberDesigned to meet the most stringent industry performance standards for superior structural integrity while providing designers with a cost-effective method to save valuable land and protect water resources.

6 The StormTech system is designed primarily to be used under parking lots, thus maximizing land usage for private (commercial) and public applications. StormTech chambers can also be used in conjunction with Green Infrastructure, thus enhancing the performance and extending the service life of these MC- 3500 Chamber (not to scale)Nominal Chamber SpecificationsSize (L x W x H) 90 x 77 x 45 2,286 mm x 1,956 mm x 1,143 mmChamber Storage f t3 ( m3)Min. Installed Storage* ft3 ( m3)Weight 134 lbs ( kg)Shipping 15 chambers/pallet 7 end caps/pallet 7 pallets/truck*Assumes a minimum of 12 (300 mm) of stone above, 9 (230 mm) of stone below chambers, 6 (150 mm) of stone between chambers/end caps and 40% stone MC- 3500 END CAP (not to scale)Nominal End Cap SpecificationsSize (L x W x H) x 71 x 673 mm x 1,803 mm x 1,145 mmEnd Cap Storage f t3 ( m3)Min.

7 Installed Storage* 3 ( m3)Weight 49 lbs ( kg)*Assumes a minimum of 12 (300 mm) of stone above, 9 (230 mm) of stone below, 6 (150 mm) of stone perimeter, 6 (150 mm) of stone between chambers/end caps and 40% stone MC- 3500 Chamber3 Storage Volume Per Chamber/End Cap ft3 (m3)Bare Unit Storage ft3 (m3)Chamber/End Cap and Stone Volume Stone Foundation Depth in. (mm)9 (230)12 (300)15 (375)18 (450)MC- 3500 ( ) ( ) ( ) ( ) ( )MC- 3500 End ( )4 ( ) ( ) ( ) ( )Note: Assumes 6 (150 mm) row spacing, 40% stone porosity, 12 (300 mm) stone above and includes the bare chamber/end cap of Excavation Per Chamber/End Cap yd3 (m3)Stone Foundation Depth9 (230 mm)12 (300 mm)15 (375 mm)18 (450 mm) ( ) ( ) ( ) ( )End ( ) (3.)

8 2) ( ) ( )Note: Assumes 6 (150 mm) of separation between chamber rows and 24 (600 mm) of cover. The volume of excavation will vary as depth of cover of Stone Per ChamberENGLISH tons (yd3)Stone Foundation Depth9 12 15 18 ( ) (6. 5 ) ( ) ( )End ( ) (2 .9)4. 3 ( ) ( )METRIC kg (m3)230 mm300 mm375 mm450 mmChamber7711 ( )8255 ( )8800 ( )9435 ( )End Cap3 5 3 8 (2 .1)3719 ( )3901 ( )4082 ( )Note: Assumes 12 (300 mm) of stone above and 6 (150 mm) row spacing and 6 (150 mm) of perimeter stone in front of end applications will be considered on a project by project basis. Please contact our application department should you have a unique application for our team to evaluate.

9 Call StormTech at or or visit our website at for technical and product MC- 4500 Chamber90"(2286 mm)61"(1549 mm) "(833 mm)INSTALLED38"(965 mm)ACTUALD esigned to meet the most stringent industry performance standards for superior structural integrity while providing designers with a cost-effective method to save valuable land and protect water resources. The StormTech system is designed primarily to be used under parking lots, thus maximizing land usage for private (commercial) and public applications. StormTech chambers can also be used in conjunction with Green Infrastructure, thus enhancing the performance and extending the service life of these MC- 4500 Chamber (not to scale)Nominal Chamber SpecificationsSize (L x W x H) 52 x 100 x 60 1321 mm x 2540 mm x 1524 mmChamber Storage f t3 ( m3)Min.

10 Installed Storage* f t3 ( m3)Weight Nominal 125 lbs ( kg)Shipping 7 chambers/pallet 5 end caps/pallet 11 pallets/truck*Assumes a minimum of 12 (300 mm) of stone above, 9 (230 mm) of stone below chambers, 9 (230 mm) of stone between chambers/end caps and 40% stone MC- 4500 end cap (not to scale)Nominal End Cap SpecificationsSize (L x W x H) 38 x 90 x 61 965 mm x 2286 mm x 1549 mmEnd Cap Storage ft3 ( m3)Min. Installed Storage* ft3 ( m3)Weight Nominal lbs ( kg)*Assumes a minimum of 12 (300 mm) of stone above, 9 (230 mm) of stone below, 12 (300 mm) of stone perimeter, 9 (230 mm) of stone between chambers/end caps and 40% stone Volume Per Chamber/End Cap ft3 (m3)Bare Unit Storage ft3 (m3)Chamber/End Cap and Stone Volume Stone Foundation Depth in.


Related search queries