Example: bankruptcy

MCCBs - ABBSales.com

15 TmaxMCCBsLow Voltage Products & Systems Inc. 888-385-1221 1 SXU000023C020216 IntroductionABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high performance, versatility and standardization in a range of molded case circuit ABB Tmax line of circuit breakers, with a range up to 3000A, has several key features that go along with its very small size: Double insulation this construction characteristic allows for the UL Listed field installation of internal accessories without exposure to energized parts.

in a range of molded case circuit breakers. The ABB Tmax line of circuit breakers, with a range up to 3000A, has several key features that go along with its very small size: • Double insulation – this construction characteristic allows for the UL Listed field installation of internal accessories without exposure to energized parts.

Tags:

  Breaker, Circuit, Circuit breakers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MCCBs - ABBSales.com

1 15 TmaxMCCBsLow Voltage Products & Systems Inc. 888-385-1221 1 SXU000023C020216 IntroductionABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high performance, versatility and standardization in a range of molded case circuit ABB Tmax line of circuit breakers, with a range up to 3000A, has several key features that go along with its very small size: Double insulation this construction characteristic allows for the UL Listed field installation of internal accessories without exposure to energized parts.

2 Complete range of electrical and mechanical accessories Positive operation breakers from ABB ensure that the toggle indicates the precise position of the moving contacts. This guarantees safe and reliable signaling by the device. Installation Tmax molded case circuit breakers can be installed in panels and switchboards in either the horizontal or vertical planes while being fed from either end without any derating of their performance characteristics. Interrupting ratings at 480 VAC up to 150kAIC. Compact size All Tmax molded case circuit breakers are UL Listed and IEC rated for global application and acceptance.

3 All versions of the Tmax family are suitable for reverse feed ABB Tmax product line has the performance and accessories to satisfy all industry requirements in the 600 VAC to 600 VDC ranges. Frame sizes Eight basic sizesThe ABB Tmax series includes eight basic frame sizes as well as the T1 single pole with the range rated from 15A to 1200A at 480 VAC. The various versions carry the following interrupting capacities: B Basic breaking capacity N Normal breaking capacity S Standard breaking capacity H High breaking capacity L Extra high breaking capacity V Very high breaking capacityDerived versions Thermal magnetic Electronic Molded case switches Motor circuit protectors (MCPs) Direct current (DC) ratedABB Tmax versions Fixed: all models Drawout or plug-in.

4 T2, T3, Ts3, T4, T5, T6 and T7 UL File #E93565 (breakers and MCPs) #E116596 (Accessories) #E116595 (Molded case switches)TmaxMolded case circuit breakersTmaxMolded case circuit Low Voltage Products & Systems 1 SXU000023C0202 ABB Inc. 888-385-1221 GuideCircuit breakers for power distributionT1 Ts31 In15A = 10kA@277 VAC 10kA@347 VAC2 In15A = 35kA@240 VAC 14kA@480Y/277 VAC3 T5 600 with electronic trip units only and in three pole version4 2p breakers: available only in N interrupting rating5 In from 15A up to 30A=65kA@480V ACT1 1P T1 T2 T3 Ts3 TypeTmax T1 1pTmax T1 Tmax T2 Tmax T3 Tmax Ts3 Tmax Ts3 Frame size[A]100100100225150225 Number of poles [Nr]13-43-43-42-3-42-3-4 Rated voltage AC (50-60Hz)[V]347600Y/347480600Y/347600480 DC[V]500500600500 Interrupting ratings BNSHNSNHLNHL240V AC[kA rms]50 26515050656510015065100150277V AC[kA rms]18 1347V AC[kA rms]14 1480V AC[kA rms]22 235652535255085 5255065600Y/347V AC[kA rms]101010600V AC[kA rms]141425250V DC (2 poles in series)

5 [kA rms]252535500V DC (3 poles in series)[kA rms]252535500V DC (2 poles in series)[kA rms]355065203550600V DC (3 poles in series)[kA rms]203550 Trip unitsTMF TMD/TMAELT MA Electronic DimensionsH[in/mm] 3p[in/mm]1 [in/mm] life[No. operations]25000250002500025000250002500 015 TmaxMCCBsLow Voltage Products & Systems Inc. 888-385-1221 1 SXU000023C020216 Selection GuideCircuit breakers for power distributionT4 T8 TypeTmax T4 Tmax T5 Tmax T6 Tmax T7 Insulated caseT8 / S8 Frame size[A]250400-600 38001000-12001600, 2000,2500 & 30003600 Number of poles [Nr]2-3-4 42-3-4 43-43-4 Rated voltage AC (50-60Hz)

6 [V]600600600600DC[V]600600600T8S8 Interrupting ratings NSHLVNSHLVNSHLSHLT8VS8V240V AC[kA rms]65 100 150 200 200 65 100 150 200 200 65 100 200 20065100150125125277V AC[kA rms]347V AC[kA rms]480V AC[kA rms]25 35 65 100 150 25 35 65 100 150 35 50 65 1005065100125100600Y/347V AC[kA rms]600V AC[kA rms]18 25 35 65 100 18 25 35 65 100 20 25 35 4225506510085250V DC (2 poles in series)[kA rms]500V DC (3 poles in series)[kA rms]500V DC (2 poles in series)[kA rms]25 35 50 65 100 25 35 50 65 100 35 35 50 65600V DC (3 poles in series)[kA rms]1625 35 50 651625 35 50 65 20 20 35 5025 6 Trip unitsTMF TMD/TMA ELTMAE lectronic DimensionsH[in/mm] / / 400W 3p[in/mm] / / 406D[in/mm] (toggle)7/178 (motor) / / 242 Mechanical life[No.]

7 Operations]20,00020,00020,00010,00015,00 010,0001 In15A = 10kA@277 VAC 10kA@347 VAC2 In15A = 35kA@240 VAC 14kA@480Y/277 VAC3 T5 600 with electronic trip units only and in three pole version-4 2p T4N250 and T5N400 available only in N interrupting In from 15A up to 30A=65kA@480 VAC6 Applies to MCS only. T4 T5 T6 T7 Low Voltage Products & Systems 1 SXU000023C0202 ABB Inc. 888-385-1221 S 080 T W - 4 xxxInterrupting rating class B = Basic N = NormalS = StandardH = HighL = Extra HighV = Very highCurrent rating 015 = 15A 080 = 80A 100 = 100A 225 = 225A 250 = 250A 400 = 400A 600 = 600A 800 = 800A1200 = 1200 ATrip unit functionB = LS/I (AC only)D = Molded Case Switch (MCS)T = Thermal-magneticM = Magnetic only (MCP)E5 = Electronic MCP (AC only)C = LSI (AC only)E = LSIG (AC only)Type connectorsW = NoneL = Lugs includedNumber of poles-1 =1 pole (T1 only)-2 = 2 pole-4 = 4 poleNone = 3 poleAccessories (added in alpha-numeric order)

8 1A = Auxiliary SwitchS_ = Shunt trip with voltage codeU_ = Undervoltage release with voltage codeFrame size T1 = 100AT2 = 100AT3 = 225 ATs3 = 225AT4 = 250AT5 = 400A, 600AT6 = 600A, 800AT7 = 1000A, 1200A1 Consult ABB for factory installed informationCatalog number explanation15 TmaxMCCBsLow Voltage Products & Systems Inc. 888-385-1221 1 SXU000023C020216T1 100A, 600Y/347V, 480V Thermal-magneticUL489 / CSA Interrupting capacity (kA RMS)VoltageContinuous ratingB (1 pole)N240 VAC15 100A 50 1347 VAC15A20 100A1014 480 VAC 15A 220 100A 1422600Y/347 VAC15 100A 10250 VDC 2 pole series15 100A 25500 VDC 3 pole series15 100A 25T1 GeneralThe T1 breaker family ranges from 15 through 100 amperes.

9 The T1 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short circuit protection for the breaker is accomplished using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected UL489/CSA version of T1 also carries an IEC-60947-2 T1 frame is available in two versions: T = Thermal-magnetic, fixed D = Molded case switchPerformance levelsThe T1 breaker has two performance levels available: B = Basic single pole N = Normal three poleNumber of polesThe T1 molded case circuit breaker is available in single, three and four pole versions.

10 Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for case switchesUL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self In 15A 35kA @ 15A available in 480/277 VAC Interrupting capacity for 16-20A is 16kADimensions 3P Fixed Version x x (Ibs)IEC 60947-2 Interrupting capacity (kA RMS)VoltageContinuous ratingB (1 pole)N230 VAC15 100A25 350415 VAC15 100A 36690 VAC15 100A 6500 VDC 2 pole series15 100A Low Voltage Products & Systems 1 SXU000023C0202 ABB Inc. 888-385-1221 schedule S1TT1 100A, 600Y/347V.


Related search queries