MCplus SERIES ACONTROLLERSOWNER'S MANUAL4,6, 8, 12, 18, 24, 30, 36 and 42 stationsThank you for purchasing the irri - trol MCplus SERIES below are some important features you should be aware ofbefore you begin programming. Details on how to implement thesefeatures are described on the following Watering Calendar from 1 to 16 days for appli-cation versatilitySensor feature in program 4 for water conservation systemsProgrammable Delay between stations to prevent pressure loss Rechargeable Battery Back-up System to maintain real time and programmed information in the event of a power failure Four independent programs for system versatilityCapability of operating up to 4 valves per station (MC-8plusthrough MC-42plus)

Thank you for purchasing the Irri-Trol MCplus Series Controller. Listed below are some important features you should be aware of before you begin programming.

Tags:

  Series, Trol, Mcplus, Mcplus series a, Irri, Irri trol mcplus series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MCplus SERIES A CONTROLLERS - NORMAC

1 MCplus SERIES ACONTROLLERSOWNER'S MANUAL4,6, 8, 12, 18, 24, 30, 36 and 42 stationsThank you for purchasing the irri - trol MCplus SERIES below are some important features you should be aware ofbefore you begin programming. Details on how to implement thesefeatures are described on the following Watering Calendar from 1 to 16 days for appli-cation versatilitySensor feature in program 4 for water conservation systemsProgrammable Delay between stations to prevent pressure loss Rechargeable Battery Back-up System to maintain real time and programmed information in the event of a power failure Four independent programs for system versatilityCapability of operating up to 4 valves per station (MC-8plusthrough MC-42plus)

2 Water Budgeting for simple, single-entry increase or decrease ofwatering time per programTotal Watering Time display for quick review of scheduledwatering time per programTrue Manual, Semi-automatic and/or Single Station TimedManual for versatile operation Incomplete Program Alert to prevent errors in programming Two-minute Test for easy system testing RF Ready for upgrading to an irri - trol Remote Control System Scrolling Program for information recall Selectable Single Program option for winter/summer programs Watering Times in seconds, minutes or hours-- Selectable Loop option for continuous cycling of program Single Entry All Stations On Time for ease of programming ( 30-,36-, and 42-station models)These are just a few of the many features of the MCplus SERIES Con-trollers.

3 Please review your manual before beginning OFCONTENTSPAGEI nstallation and Wiring .. 5 Basic Programming Instructions:Set Erase ( ).. Operation:True Station Timed Off/2 Min. of Program:Set Time/Total Watering Start/Cycle Features:Automatic Safety Back-up Program (ASBP)..Programmable Watering Delay Between Program Water Stations Watering SERIESCONTROLLERS12789101112131415161718 19202122232425110/24 volt transformerTerminal Strip-for 24v, sensor, common, master valve and individualstation hook-upsSet Time Key-to enter the current time of day and start the digital clockManual On/Off Key-for manual and semi-automatic operationsStation indication LEDsPE/Calendar position-to select programs to be erased and/or to selectand display Watering CalendarRain Off /2 Min.

4 Test position-to select the Rain Off mode and/or theTwo-minute TestManual position-for true manual operationAuto/Run position-to lock keyboard when not programmingCircuit Breaker-will reset when controller is overloaded to preventdamage to the controller; 24 VAC, ampsProgram positions 1 through 4-to select desired programNumber Keys 0 through 9-for programming applicationsDigital Display-for viewing current time and programmed informationEnter Key-enters Water Time and Cycle Start functionsWater Time Key-for individual programming and/or recall of stationWatering TimesCycle Start Key-for programming and/or recall of Cycle Start TimesDay Off Key-for scheduling and/or recalling non-watering daysDay On Key-for scheduling and/or recalling watering daysClear Key-for clearing entries from the displayPM/% Key-for setting a time function in the period and/or forselecting the Water

5 Budgeting featureSet Today Key-for setting the current day of the weekRF Connector-for hook-up of an irri - trol Remote Valve ControlOption Switches-for selecting additional features (see page 13)Rechargeable Battery Back-up Case and ConnectorLower Face Plate4 INSTALLATIONINSTRUCTIONSMOUNTING THECONTROLLERThe controller is in an outdoor, rain-tight, rust-resistant and dust-proof , controller MUST be installed away from direct sprinkler also should be placed in a shaded and dry location, if possible. DO NOTinstall in closed and humid environment, or in an area subjected to continualheavy MOUNT: For Wall Mounting, install controller vertically on flat, securesurface.

6 Use the enclosed template to locate mounting screw holes. Followcomplete mounting instructions on : For free-standing installation on a pedestal, follow the instal-lation instructions in the pedestal : The controller should not be placed where it is exposed to atemperature exceeding 130 1. To begin, remove the lower panel by unfastening the screws located onHOOK-UP each side. Follow the wiring diagram shown in Figure 1, Strip wiresapproximately l/4 (do not bend exposed end). Insert straight bare wirebetween plates of sure grip terminal. Tighten screw firmly. Follow allapplicable local electrical wiring codes,Figure 1 COMMONIMPORTANT: Use a separate (dedicated) valve common for each : Make certain that the 120 VAC 60Hz supply is attached to the blackand white wires of the transformer.

7 The yellow and red wires go to the 24 VAC input on the terminals of the : NEVER short wires in order to identify a station or to verify powerfrom 24-volt side of transformer. This will result in damage to controllerand/or A maximum of FOUR 4-watt solenoid valves may be connected to eachstation. Exception: MC-4plus & -6p/us, maximum of TWO 4-watt maximum of FOUR 4-watt solenoid valves may be programmed to In cases where a pump is to be controlled by the master valve output, DONOT drive the pump directly from the controller. The master station must beconnected to the coil of a 24 VAC relay, such as an Essex# 184-20105-101 Z( irri - trol part no.)

8 I 1001). The pump latch relay should be set up by anelectrician so that a switch closure will activate the latch relay coil, turning onthe pump. The switch contacts of the Essex relay should be connected tocontrol the latch relay coil (See Figure 2). The relay should be mounted atleast 5 feet from the controller box and the box MUST be must follow all local electrical wiring / 440 Before power is turned on, re-check all leadsconnected to the terminal block for shorts and/orincorrect terminal assignment. Then turn on power Battery Back-up: The controller is equipped with a rechargeable batteryback-up circuit in case of a temporary power failure (batteries not included).

9 The batteries will retain real time and will hold all program information forabout 4 The battery pack is located on the back of the Board. This packis designed for 4 AA NICAD RECHARGEABLE batteries (notincluded).CAUTION: Use of other types of batteries may damage IT IS MANDATORY that the batteries be installed only AFTER power is turned on and programming has been : Whenever working in the field while power is on, the commonwire must be disconnected from the controller s terminal block. This willeliminate any possible 24-volt controller is a solid-state microcomputer that may be affected bytransient surges and electromagnetic interference.

10 Care must be taken notto install controller on a circuit controlled by a switch or on the same circuitas a high power user ( refrigerator, air conditioner or a large horse-power pump or motor). In addition, the controller must be installed at least 15feet from a high power user. Valve and power wires must also be routedaway from high power users. This controller has been equipped with a floating valve common. It is notreferenced to earth ground. This will not affect operation of your SERIESCONTROLLERSFor safety, transient protection and increased reliability, con-troller MUST be should be installed using a three wire 110 VACsupply with a verified third wire ground.