McQuay Enfinity TM Horizontal & Vertical Water …

Catalog 1100-6. McQuay Enfinity Horizontal & Vertical TM. Water Source heat Pump 1/2 to 5 Ton Model CCH & CCW Ceiling Concealed Size 007 060. Model FCV & FCW Vertical Floor Size 007 060. Table of Contents Product Models .. 1 Dimensional Horizontal (Left Hand) Sizes 007, 009, 51. Horizontal Ceiling Design Horizontal (Right Hand) Sizes 007, 009, 52. Horizontal Features & 4-6 Horizontal (Left Hand) Sizes 019, 53. Vertical Ceiling Design Horizontal (Right Hand) Sizes 019, 54. Vertical Features & 8-9 Horizontal (Left Hand) Sizes 030, 55. Enfinity Product Horizontal (Right Hand) Sizes 030, 56. Horizontal (Left Hand) Sizes 042, 048, 57. Control Options - 3 Unique Control Horizontal (Right Hand) Sizes 042, 048, 58. Mark IV ..13. Filter Rack, Return Air Duct 59. Microtech 2000 .. 14. Alerton BACnet .. 15-16 Vertical Unit ISO Performance ISO Performance Data - Water 60. Applications - 17-19. ISO Performance Data - Ground 61. Heating and Cooling Refrigeration ISO Performance - Ground 62.

McQuay Enfinity TM Horizontal & Vertical Water Source Heat Pump – 1/2 to 5 Ton Model CCH & CCW Ceiling Concealed – Size 007–060 Model …

Tags:

  Course, Water, Heat, Horizontal, Vertical, Mcquay, Mcquay enfinity tm horizontal amp vertical water, Enfinity, Mcquay enfinity tm horizontal amp vertical water source heat

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of McQuay Enfinity TM Horizontal & Vertical Water …

1 Catalog 1100-6. McQuay Enfinity Horizontal & Vertical TM. Water Source heat Pump 1/2 to 5 Ton Model CCH & CCW Ceiling Concealed Size 007 060. Model FCV & FCW Vertical Floor Size 007 060. Table of Contents Product Models .. 1 Dimensional Horizontal (Left Hand) Sizes 007, 009, 51. Horizontal Ceiling Design Horizontal (Right Hand) Sizes 007, 009, 52. Horizontal Features & 4-6 Horizontal (Left Hand) Sizes 019, 53. Vertical Ceiling Design Horizontal (Right Hand) Sizes 019, 54. Vertical Features & 8-9 Horizontal (Left Hand) Sizes 030, 55. Enfinity Product Horizontal (Right Hand) Sizes 030, 56. Horizontal (Left Hand) Sizes 042, 048, 57. Control Options - 3 Unique Control Horizontal (Right Hand) Sizes 042, 048, 58. Mark IV ..13. Filter Rack, Return Air Duct 59. Microtech 2000 .. 14. Alerton BACnet .. 15-16 Vertical Unit ISO Performance ISO Performance Data - Water 60. Applications - 17-19. ISO Performance Data - Ground 61. Heating and Cooling Refrigeration ISO Performance - Ground 62.

2 Boiler Tower Open Loop Well Water Vertical Capacity Closed Loop Geothermal Cooling - Size 63. Vertical Heating - Size 64. Horizontal Cooling - Size 65. Surface Water (Lake)..19 Heating - Size 66. Applications 20-21 Cooling - Size 67. Typical Horizontal Heating - Size 68. Unit Cooling - Size 69. Heating - Size 70. Condensate Drain Cooling - Size 71. Ductwork & Sound Considerations .. 21 Heating - Size 72. Cooling - Size 73. Typical Vertical Heating - Size 74. Unit Cooling - Size 75. Heating - Size 76. Condensate Drain Cooling - Size 77. Applications - Unit Heating - Size 78. Cooling - Size 79. Horizontal Unit ISO Performance 24-26 Heating - Size 80. ISO Performance Data - Water Cooling - Size 81. ISO Performance Data - Ground Heating - Size 82. ISO Performance - Ground Capacity 27-40 Performance Data - Operating 83. Cooling - Size Correction 84. Heating - Size Electrical 85. Cooling - Size Fan 86. Heating - Size Physical 86. Cooling - Size Dimensional Heating - Size Vertical (Left & Right Hand) Sizes 007, 009, 87.

3 Cooling - Size Vertical (Left & Right Hand) Sizes 019, 88. Heating - Size Vertical (Left & Right Hand) Sizes 030, 89. Cooling - Size Heating - Size Vertical (Left Hand) Sizes 042, 048, 90. Cooling - Size Vertical (Left & Right Hand) Size 91. Heating - Size Wiring Cooling - Size Mark IV/AC - 007 thru 92. Heating - Size Microtech 2000 - 007 thru 93. Cooling - Size Alerton BACnet - 007 thru 94. Heating - Size Cooling - Size Control Connection 95. Heating - Size Field Installed Cooling - Size Heating - Size Guide Performance Data - Operating 47. Correction 48. Electrical 49. Fan 50. Model Nomenclature Horizontal Ceiling Unit (Size 007 - 060). NOTE: For illustration purposes only. Not all options available with all models. Please consult McQuay Sales Representative for specific availability. W CCH 1 019 M E Y L S Product Category Discharge Air W = WSHP S = Straight E = End Product Identifier CCH = Ceiling Mounted/Standard Range CCW = Ceiling Mounted/Geothermal Return Air L = Left Design Series R = Right 1 = A Design 2 = B Design 3 = C Design Future 4 = D Design (None).

4 Nominal Capacity 007 = 7,000 BTU/h Voltage 009 = 9,000 BTU/h Controls A = 115/60/1. 012 = 12,000 BTU/h M = Mark IV E = 208-230/60/1. 019 = 19,000 BTU/h K = MicroTech 2000 , LonMark F = 208-230/60/3. 024 = 24,000 BTU/h L = MicroTech 2000 , LonTalk J = 277-265/60/1. 030 = 30,000 BTU/h A = Alerton BACnet K = 460/60/3. 036 = 36,000 BTU/h E = Less Board L = 575/60/3. 042 = 42,000 BTU/h 50 Hz 048 = 48,000 BTU/h M = 230/50/1. 060 = 60,000 BTU/h N = 380/50/3. Vertical Floor Unit (Size 007 - 060). W FCV 1 009 M E Y L T Product Category Discharge Air W = WSHP T = Top Product Identifier FCV = Floor Mounted/Standard Range FCW = Floor Mounted/Geothermal Return Air L = Left Design Series R = Right 1 = A Design 2 = B Design 3 = C Design Future 4 = D Design (None). Nominal Capacity 007 = 7,000 BTU/h 009 = 9,000 BTU/h Voltage 012 = 12,000 BTU/h A = 115/60/1. 019 = 19,000 BTU/h Controls E = 208-230/60/1. 024 = 24,000 BTU/h M = Mark IV F = 208-230/60/3. 030 = 30,000 BTU/h K = MicroTech 2000 , LonMark J = 277-265/60/1.

5 036 = 36,000 BTU/h L = Microtech 2000 , LonTalk K = 460/60/3. 042 = 42,000 BTU/h A = Alerton BACnet L = 575/60/3. 048 = 48,000 BTU/h E = Less Board 50 Hz 060 = 60,000 BTU/h M = 230/50/1. N = 380/50/3. Bold = R-22 Refrigerant Italic = R-410A Refrigerant Catalog 1100 McQuay Enfinity Water Source heat Pumps . Introduction McQuay Enfinity Water Source heat Pumps Horizontal (Ceiling) Water Source heat More than 30 years ago, McQuay designed the first complete line of Water source heat pumps for high efficien- Pumps Sizes 007-060 (1/2 to 5 Tons). Model CCH (Standard Range: 55 F to 110 F). cy, individually-zoned comfort control in offices, schools, Model CCW (Geothermal Range: 30 F to 110 F). assisted living facilities, manufacturing facilities and other commercial buildings. Our reputation for outstanding reli- ability and quiet operation has been reinforced in thousands of successful installations. McQuay Enfinity Water source heat pumps incorpo- rate the best of our past and the best of what's new.

6 Using feedback from building owners, consulting engineers, contractors and service engineers, we designed Enfinity products to give you maximum flexibility to design, install, operate and maintain the ideal Water source heat pump system for your building project. And we incorporated Vertical (Floor) Water Source heat Pumps non-ozone depleting R-410A refrigerant, which along with high Energy Efficiency Ratios (EER's) helps preserve our Sizes 007-060 (1/2 to 5 Tons). environment and precious energy resources. Model FCV (Standard Range: 55 F to 110 F). Model FCW (Geothermal Range: 30 F to 110 F). McQuay Air Conditioning plant with over 450,000 square feet of manufacturing space - located in Auburn, New York With McQuay Enfinity Water Source heat Pumps, you benefit from: MicroTech 2000 unit controllers are LonMark certified High efficiency, low operating costs. Easy, low cost design and installation. Standard or extended range/geothermal application flexibility.

7 McQuay is a registered trademark of McQuay International. McQuay International 2005. All rights reserved throughout the Superior indoor air quality. world. The information in this manual supersedes and replaces previous Quiet, reliable operation. catalogues with regards to McQuay Water Source heat Pump prod- ucts. Illustrations cover the general appearance of McQuay Interna- Easy, low-cost maintenance and service. tional products at the time of publication and McQuay International reserves the right to make changes in design and construction at anytime without notice. The following are trademarks or registered trademarks of their respective companies: LonTalk from Echelon Corporation, BACnet from ASHRAE, Protocol Selectability, and MicroTech II from McQuay International. McQuay Enfinity Water Source heat Pumps Catalog 1100. Horizontal Ceiling Design Features Fan Section Fan section is separated from the compressor section with an insulated Cabinet Durable, heavy gauge galvanized Removable Access Panels Both end and divider panel for maximum sound attenua- steel cabinet construction.

8 Side panels provide easy access to com- tion. A large removable panel provides easy pressor compartment, blower and motor. service access to the blower and motor. End panel provides easy access to the unit controls. Right Hand Return, End Discharge Shown Blower Motor Multi-speed, PSC type with thermal overload protection. The motor is Piping Connections Water connec- isolated from the fan housing for tions are FPT Water fittings, flush with minimum vibration transmission. Remov- the outside of the cabinet, allowing easy able orifice ring allows easy removal of one-wrench connection of units. The large Compressor Mounted close to the ac- blower and motor. condensate connection provides for proper cess panel for maximum serviceability and isolated from the bottom panel with rubber condensate removal. isolators. Flexible Cabinet Configurations Cabinet Configurations Left Hand Cabinet Configurations Right Hand Figure 4A - Left Hand Figure 4B - Left Hand Figure 4C - Right Figure 4D - Right Hand Return with End Return with Straight Hand Return with End Return with Straight Discharge Discharge Discharge Discharge Catalog 1100 McQuay Enfinity Water Source heat Pumps.

9 Horizontal Features and Benefits Enfinity Horizontal Units Available in Five Cabinet Low Design And Installation Costs Sizes: 007 & 009, 012, 019 & 024, 030 & 036, 042. thru 060 Four configurations for each unit size (left or right re- turn and straight or end discharge) allow you to specify units to fit space requirements and to design the system using minimum ductwork and piping. Five cabinet sizes, each with McQuay 's low-profile design, make it easy to meet the space requirements of your new construction or replacement application. Flush FPT Water fittings allow easy, one-wrench con- nection of units and help reduce delays caused by ship- Cabinet ping damage. McQuay Enfinity Horizontal Water source heat pumps are available in five cabinet sizes, each with the lowest pos- Flexible control options that include standalone or sible profile to conserve space. network operation with the building automation system Consistencies in shape, connection locations, parts and of your choice using LonMark or Alerton BACnet.

10 Assemblies throughout the five cabinets make layout, instal- communications. lation and service simple. High Energy Efficiency All Water and electrical connections are made from the front of the unit. High unit EERs result in low operating costs. A large, lift-up-and-out panel provides easy access to Each unit includes a thermal expansion valve for precise the control box, refrigeration circuit and compressor. refrigerant flow metering to meet load requirements and increase efficiency at any fluid temperature, including A second large panel provides easy service access to the low temperature geothermal applications. compressor. The coaxial heat exchanger is designed for maximum A third large panel allows complete service of the heat transfer at normal and low Water flow rates with blower section while the unit is hanging and without minimum pressure drop. disconnecting the unit from the ductwork. High efficiency fan motor and low-speed fan operation Cabinet surfaces are constructed of unpainted, G-60 reduce energy consumption.