MECHANICAL SYMBOLS AND ABBREVIATIONS

NTSMECHANICAL LEGENDS AND INTO TODRAWING/DETAIL NUMBERSHEET NUMBERRE: 2 NOTE REFERENCE ( , NOTES BY SYMBOL)1 MISCELLANEOUSDRAWING/DETAIL REFERENCEABBREVIATIONSGENERAL NOTESMECHANICAL SYMBOLS AND ABBREVIATIONSNOTE: ALL SYMBOLS AND ABBREVIATIONS SHOWNARE NOT NECESSARILY USED ON THE DRAWINGSDIFFUSER, GRILLE DESIGNATIONAMOUNT OF AIRNECK SIZE OR WIDTH X HEIGHT (FOR LOUVERS)A10X1025020X2020X2020X2020X20 20X2016X2020X20 SYMBOLSSYMBOLDESCRIPTION (4-WAY UNLESS OTHERWISE INDICATED)SQUARE CEILING DIFFUSER (SUPPLY)(RETURN OR EXHAUST)MANUAL VOLUME DAMPERMOTORIZED DAMPERTHERMOSTAT (OR) TEMP SENSORFIRE DAMPERSQUARE CEILING GRILLEDUCT SPLITTER WITH DAMPERFDMTorVOLTSVUNIT HEATERUHTRANSFER AIRT/ATHERMOSTAT, ROOM SENSORT, TSTATSPECIFICATIONSSPECSSQUARE FOOT, SUPPLY FANSFSUPPLY AIRS/ARETURN AIRR/APURGE EXHAUST FANPEFON CENTERO/CMBH1000 BRITISH THERMAL UNITS / HOURGALLONS PER MINUTEGPMFLOORFLRFT. FOOT, FEETFDFIRE DAMPEREFEXHAUST FANEDHELECTRIC DUCT HEATEREQUIPMENTEQUIP DNDOWNCOOLING COILCCCLGCEILINGBTUBRITISH THERMAL UNIT PER HOURW/OWBULTSTATTHRURMRLARE:PSIPROVIDEPH O/AN/O,N/CN/AMINMCALWTLRALBLkWJUNCTION BOXINCH, INCHESHERTZHORSEPOWERHEIGHTEXHAUST AIRCONDENSING UNITAIR HANDLING UNITABOVE FINISHED ) DEGREES FAHRENHEITKILOWATTLENGTHPOUNDSLOCKED ROTOR AMPSLEAVING WATER TEMPERATUREMINIMUM CIRCUIT AMPACITYMINIMUMNOT APPLICABLENORMALLY OPEN, NORMALLY CLOSEDOUTSIDE AIR/FRESH AIRPHASEFURNISH AND INSTALLPOUNDS PER SQUARE INCHREFERENCE, REFERRUNNING LOAD AMPSROOMTHROUGHTHERMOSTAT OR ROOM SENSOR

Feb 06, 2012 · specs specifications sf square foot, supply fan s/a supply air r/a return air pef purge exhaust fan o/c on center mbh 1000 british thermal units / hour gpm gallons per minute flr floor ft. foot, feet fd fire damper ef exhaust fan edh electric duct heater equip equipment dn down cc cooling coil clg ceiling btu british thermal unit per hour w/o ...

Tags:

  Spec, Floor

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MECHANICAL SYMBOLS AND ABBREVIATIONS

1 NTSMECHANICAL LEGENDS AND INTO TODRAWING/DETAIL NUMBERSHEET NUMBERRE: 2 NOTE REFERENCE ( , NOTES BY SYMBOL)1 MISCELLANEOUSDRAWING/DETAIL REFERENCEABBREVIATIONSGENERAL NOTESMECHANICAL SYMBOLS AND ABBREVIATIONSNOTE: ALL SYMBOLS AND ABBREVIATIONS SHOWNARE NOT NECESSARILY USED ON THE DRAWINGSDIFFUSER, GRILLE DESIGNATIONAMOUNT OF AIRNECK SIZE OR WIDTH X HEIGHT (FOR LOUVERS)A10X1025020X2020X2020X2020X20 20X2016X2020X20 SYMBOLSSYMBOLDESCRIPTION (4-WAY UNLESS OTHERWISE INDICATED)SQUARE CEILING DIFFUSER (SUPPLY)(RETURN OR EXHAUST)MANUAL VOLUME DAMPERMOTORIZED DAMPERTHERMOSTAT (OR) TEMP SENSORFIRE DAMPERSQUARE CEILING GRILLEDUCT SPLITTER WITH DAMPERFDMTorVOLTSVUNIT HEATERUHTRANSFER AIRT/ATHERMOSTAT, ROOM SENSORT, TSTATSPECIFICATIONSSPECSSQUARE FOOT, SUPPLY FANSFSUPPLY AIRS/ARETURN AIRR/APURGE EXHAUST FANPEFON CENTERO/CMBH1000 BRITISH THERMAL UNITS / HOURGALLONS PER MINUTEGPMFLOORFLRFT. FOOT, FEETFDFIRE DAMPEREFEXHAUST FANEDHELECTRIC DUCT HEATEREQUIPMENTEQUIP DNDOWNCOOLING COILCCCLGCEILINGBTUBRITISH THERMAL UNIT PER HOURW/OWBULTSTATTHRURMRLARE.

2 PSIPROVIDEPHO/AN/O,N/CN/AMINMCALWTLRALBL kWJUNCTION BOXINCH, INCHESHERTZHORSEPOWERHEIGHTEXHAUST AIRCONDENSING UNITAIR HANDLING UNITABOVE FINISHED ) DEGREES FAHRENHEITKILOWATTLENGTHPOUNDSLOCKED ROTOR AMPSLEAVING WATER TEMPERATUREMINIMUM CIRCUIT AMPACITYMINIMUMNOT APPLICABLENORMALLY OPEN, NORMALLY CLOSEDOUTSIDE AIR/FRESH AIRPHASEFURNISH AND INSTALLPOUNDS PER SQUARE INCHREFERENCE, REFERRUNNING LOAD AMPSROOMTHROUGHTHERMOSTAT OR ROOM SENSORUNDERWRITERS LABORATORIES, BULBWITHOUTDEGREESDEGFIRE SMOKE DAMPERFSDAPPROXIMATEAPPROXARCHITECT/ENGI NEERA/EEQUIPMENT DRAINDEXISTING(E)FAN COIL UNITFCUACCESS DOORADA/CAIR CONDITIONING UNITAIR FLOW SWITCHAFSBRAKE HORSE POWERBHPCOMBUSTION AIRC/ACUBIC FEET PER HOURCFHCUBIC FEET PER MINUTECFMDBDRY BULBENTERING AIR TEMPERATUREEATENTERING WATER TEMPERATUREEWTFLAFULL LOAD AMPSFPVAVFAN POWERED VAVFEET WATER GAUGEFT. GAUGEHEATING WATER RETURNHWRHWSHEATING WATER SUPPLYINCHES WATER AIR TEMPERATURELATLPCLOW PRESSURE CONDENSATELOW PRESSURE STEAMLPSHIGH PRESSURE CONDENSATEHPCHIGH PRESSURE STEAMHPSMAXIMUMMAXMFRMANUFACTURERSMOKE DETECTORSDVELOCITYVELWITHW/VARIABLE FREQUENCY DRIVEVFDVAVVARIABLE AIR VOLUMETOTAL STATIC PRESSURETSPTYPICALTYPOPPOSED BLADE DAMPEROBDPRVPRESSURE REDUCING VALVEREFRIGERANT LIQUIDRLRSREFRIGERANT SUCTIONREVOLUTIONS PER MINUTERPMDR=3D/2WR=3W/220X20 ACOUSTICAL DUCT LINING (FIGURESSHOWN ARE INSIDE DUCT DIMENSIONSSUPPLY AIR DUCT UP (POSITIVE PRESSURE)RETURN, EXHAUST OR OUTSIDE AIR INTAKEDUCT UP (NEGATIVE PRESSURE)SUPPLY AIR DUCT DOWN (POSITIVE PRESSURE)RETURN, EXHAUST OR OUTSIDE AIR INTAKEDUCT DOWN (NEGATIVE PRESSURE)ROUND DUCT UPTRANSITION CONCENTRIC UNLESS TOP LEVEL(TOP LVL)OR BOTTOM LEVEL(BOT LVL) IS NOTEDTRANSITION, RECTANGULAR TO ROUND CONCENTRICUNLESS TOP LEVEL (TOP LVL) OR BOTTOM LEVEL(BOT LVL)

3 IS NOTEDROUND DUCT RADIUS ELBOWRECTANGULAR DUCT RADIUS ELBOWRECTANGULAR DUCT SQUARE ELBOW WITHTURNING VANESROUND DUCT NUMBERM3011 SHEET NUMBERFSDFIRE SMOKE DAMPERPRIMARY MECHANICAL CODES : MECHANICAL :2003 INTERNATIONAL MECHANICAL CODE (WITH CITY AMENDMENTS).ENERGY:2003 INTERNATIONAL ENERGY CODE (WITH CITY AMENDMENTS).PROJECT DESIGN VALUES :OUTDOOR DESIGN TEMPERATURE (SUMMER): ) '5<%8/% ) :(7%8/% AMBIENT TEMPERATURE AT CONDENSING UNITS: ) '5<%8/% 6800(5 OUTDOOR DESIGN TEMPERATURE (WINTER): ) '5<%8/% INDOOR DESIGN TEMPERATURE (SUMMER): ) '5<%8/% 5(/$7,9( +80,',7< INDOOR DESIGN TEMPERATURE (WINTER): ) '5<%8/% OUTSIDE AIR REQUIREMENTS:PER IMC TABLE AUTOMATION SYSTEMBASPERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE CODES AND AUTHORITIESHAVING JURISDICTION. PROVIDE ALL PERMITS, INSPECTIONS, LICENSES AND FEES. FURNISHALL LABOR, EQUIPMENT, SUPPLIES AND MATERIALS NECESSARY TO PROVIDE COMPLETE ANDOPERATIONAL DRAWINGS AND SPECIFICATIONS INDICATE THE GENERAL DESIGN AND ARRANGEMENTOF PIPES, FIXTURES, EQUIPMENT, SYSTEMS, ETC.

4 INFORMATION SHOWN IS DIAGRAMMATIC INCHARACTER AND DOES NOT NECESSARILY INDICATE EVERY REQUIRED OFFSET, FITTING, NOT SCALE THE DRAWINGS FOR DIMENSIONS. TAKE ALL DIMENSIONS, MEASUREMENTS,EQUIPMENT LOCATIONS, LEVELS, ETC FROM THE ARCHITECTURAL DRAWINGS AND FROM THEEQUIPMENT TO BE FURNISHED. PIPING MAY BE RELOCATED OR OFFSET FOR PROPERCLEARANCES OR TO AVOID CONFLICTS WITH OTHER TRADES. THE DESIGN INTENT ( , VELOCITIES, PRESSURE DROPS, VOLTAGE DROPS, ETC) CANNOT BE GREATLYALTERED WITHOUT THE APPROVAL OF THE ARCHITECT. THE COST OF THESE DEVIATIONS TOAVOID INTERFERENCE'S SHALL BE PART OF THE ORIGINAL CONTRACT SUBCONTRACTOR SHALL CONFER AND COOPERATE WITH ALL OTHER TRADES TOCOORDINATE THEIR WORK. COORDINATION SHALL INCLUDE, BUT SHALL NOT BE LIMITED TOMATERIALS AND EQUIPMENT ROUTED IN CEILING AND WALL CAVITIES, EQUIPMENTARRANGEMENT IN MECHANICAL SPACES, INCLUDING EQUIPMENT CLEARANCEREQUIREMENTS, ELEVATIONS AND DIMENSIONS OF STRUCTURAL MEMBERS AND OPENINGS,ETC.

5 THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY FINAL INSTALLATION OF MATERIALS AND EQUIPMENT ON ACTUAL DIMENSIONS ANDCONDITIONS AT THE PROJECT SITE. FIELD MEASURE FOR MATERIALS AND EQUIPMENTREQUIRING EXACT FIT. NO EXTRAS WILL BE GIVEN FOR THE CONTRACTORS FAILURE TOFIELD OWNER OR ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETYPRECAUTIONS OR FOR MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, ORPROCEDURES REQUIRED TO PERFORM THE CONTRACTOR SHALL LOCATE ALL EQUIPMENT THAT MUST BE SERVICED, OPERATED, ORMAINTAINED IN FULLY ACCESSIBLE POSITIONS. EQUIPMENT SHALL INCLUDE (BUT NOTLIMITED TO) VALVES, MOTORS, CONTROLLERS, SWITCHGEAR, AND DRAIN POINTS IFREQUIRED FOR BETTER ACCESSIBILITY. FURNISH ACCESS DOORS FOR THIS DEVIATIONS FROM THE DRAWINGS MAY BE ALLOWED TO PROVIDE FOR BETTERACCESSIBILITY. ANY CHANGES SHALL BE APPROVED BY THE ARCHITECT AND CONSTRUCTIONMANAGER/GENERAL CONTRACTOR PRIOR TO MAKING THE CONTRACTOR SHALL PROVIDE ACCESS DOORS, WALL OPENINGS, ROOF OPENINGS ORANY OTHER CONSTRUCTION REQUIREMENT NEEDED TO ACCOMMODATE THE MECHANICALEQUIPMENT.

6 LOCATIONS OF THESE OPENINGS SHALL BE SUBMITTED IN SUFFICIENT TIME TOBE INSTALLED IN THE NORMAL COURSE OF CONTRACTOR SHALL COORDINATE ELECTRICAL REQUIREMENTS OF APPROVEDEQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO THE PURCHASE ANDINSTALLATION OF ANY ELECTRICAL GEAR OR CONTROL WIRING, THERMOSTATS, MOTORIZED DAMPERS AND CONDUIT ASSOCIATEWITH HVAC EQUIPMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTORSHALL COORDINATE THE LOCATION OF ALL THERMOSTATS, ROOM SENSORS, ETC WITH THEARCHITECT AND ALL OTHER TRADES PRIOR TO INSTALLATION. IF A CONFLICT WITHMILLWORK, LIGHT SWITCHES, WINDOWS, ETC EXISTS, THE CONTRACTOR SHALL NOTIFY THEARCHITECT OF THE POTENTIAL INTERFERENCE PRIOR TO INSTALLATION. INSTALLTHERMOSTATS WITH PROTECTIVE LOCKING COVER, CENTERED AT 4'-0" ABOVE FINISHEDFLOOR, UNLESS OTHERWISE INDICATED. COMPLY WITH THE PROVISIONS OF THE AMERICANSWITH DISABILITIES ACT (ADA) AND THE TEXAS ACCESSIBILITY'S STANDARD (TAS).

7 ALL DIMENSIONS SHOWN ON THE DRAWINGS FOR DUCTWORK ARE NET INSIDE CLEARDIMENSIONS. FOR RECTANGULAR DUCT, THE FIRST FIGURE OF THE DUCT SIZE INDICATESTHE DIMENSION OF THE FACE SHOWN. VERIFY THAT THE DUCTWORK SPECIFIED WILL FIT INTHE SPACE AVAILABLE USING THE ARCHITECTURAL, STRUCTURAL AND ELECTRICALDRAWINGS AS REFERENCE PRIOR TO FABRICATION AND INSTALLATION. ROUND DUCT OFEQUAL NET INSIDE CLEAR AREA MAY BE USED IN LIEU OF RECTANGULAR TURNING VANES ON ALL RECTANGULAR SUPPLY, EXHAUST AND RETURNDUCTWORK INCLUDING THE TOP AND BOTTOM OF VERTICAL A LOCKING QUADRANT VOLUME DAMPER AT THE TAP OF EACH RUN-OUT TODIFFUSERS FOR BALANCING PURPOSES, UNLESS OTHERWISE INDICATED. THE RUN-OUTDUCT SIZE IS THE SAME SIZE AS THE DIFFUSER OR GRILLE NECK SIZE UNLESS SPACE IS NEEDED AS A RETURN AIR PLENUM IN CERTAIN AREAS. FOLLOW ALLAPPLICABLE CODES AS TO MATERIALS ALLOWED FOR USE IN AIR PLENUMS.

8 COORDINATEWITH THE GENERAL CONTRACTOR TO PROVIDE FREE RETURN OF AIR FROM ALL TO ARCHITECTURAL DRAWINGS FOR LOCATION OF ALL FIRE RATED WALLS ANDCEILINGS. PROVIDE FIRE DAMPERS AND/OR COMBINATION FIRE/SMOKE DAMPERS INDUCTWORK AT ALL LOCATIONS WHERE DUCTS PASS THROUGH FIRE RATED CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROVIDING FIREAND SMOKE DAMPERS. COORDINATE CONSTRUCTION REQUIREMENTS WITH OF ALL GRILLES, REGISTERS, DIFFUSERS AND CEILING DEVICES SHALL BEDETERMINED FROM THE ARCHITECTURAL REFLECTED CEILING PLANS AND WALL ALL CEILING DIFFUSERS AND GRILLE LOCATIONS WITH LOCATION OF DUCTWORK SHALL BE SHEET METAL FABRICATED IN ACCORDANCE WITH SMACNASTANDARDS. ALL DUCT WORK FROM AHU TO TERMINAL UNIT SHALL BE CONSTRUCTED TO 1" AND SEALED TO SMACNA CLASS A. DUCT WORK DOWN STREAM OF TERMINAL UNITSSHALL BE CONSTRUCTED TO 1/2" AND SEALED TO SMACNA CLASS C. SEAL ALL SEAMSWITH UL 181 MASTIC RATED FOR DX PIPING AS SPECIFIED, INCLUDING FILTER/DRYER, SIGHT GLASS,ISOLATION/CHARGING VALVES AND ALL APPURTENANCES PER MANUFACTURER'SRECOMMENDATIONS.

9 INSTALLATION SHALL BE ACCOMPLISHED IN A NEAT AND ORDERLYFASHION, AS APPROVED BY THE ENGINEER. COORDINATE FOR ROUTING OF DX PIPING, UPINSIDE OF WALLS, ETC. AS REQUIRED, TERMINATING AT AHU's. PROVIDE BRACING/ISOLATION,AS REQUIRED TO PREVENT VIBRATION OF DX PIPING INSIDE WALLS, ETC. SIZE, ROUTE ANDINSULATE DX PIPING PER MANUFACTURER'S RECOMMENDATIONS AND VIBRATION ISOLATORS FOR MOTOR DRIVEN EQUIPMENT UNLESS NOTEDOTHERWISE. PROVIDE ISOLATION AS INDICATED OR AS RECOMMENDED BY THE PIPES AND DUCTS SHOWN ON EACH floor PLAN MAY BE SHOWN WITH AN OFFSETFOR ALL PIPE AND DUCT PENETRATIONS THROUGH FIRE RATED BUILDING ELEMENTS WITHAN APPROVED FIRE PROOFING EQUIPMENT SHALL HAVE IDENTIFICATION TAGS. TAGS SHALL BE PLASTIC LAMINATE,WHITE FACE WITH 1/2" TALL BLACK LETTERS. THE TAG SHALL MATCH THE UNITDESIGNATIONS SHOWN ON THE CONTRACTOR SHALL EXPAND OR REDUCE DUCTS AT EQUIPMENT CONNECTIONS BASEDON THE EQUIPMENT PURCHASED, WITH TRANSITIONS NOT TO EXCEED 30 DEGREES.

10 SIZESSHOWN ON SCHEDULES, ETC. ARE FOR GUIDANCE ONLY. ASPECT RATIO SHALL BE NOGREATER THAN 4:1, PER SMACNA'S DUCTS WITH A DIMENSION GREATER THAN 12" PASSING THRU A NON-RATED WALL SHALLHAVE THE OPENING FRAMED IN WITH METAL STUDS. CONTRACTOR SHALL COORDINATEOPENING SIZE AND LOCATION WITH OTHER TO INSTALLATION COORDINATE ALL MECHANICAL WORK WITH PNEUMATIC TUBESYSTEM BY TO BE REMOVED(D)EQUIPMENT TO BE RELOCATED(R)(N)NEW WORTH, TEXAS 761162570 RIVER PARK PLAZA SUITE 100 EMAIL: 817-377-3612 PHONE: 817-377-3600A NEW LEASE FACILITY FORCITY OF WESTWORTH VILLAGE, TEXASC. CONNELLY SURVEY ABSTRACT No. 319 TARRANT CO., TX2/6 "x14" AHU-1EF-3A640B10260A635A640A10210A12430A 10365A12430G22/22G22/22B10360G22/22B1025 0E8250M8M8E8250E8250A12345A695 VAV-2-3 VAV-2-2 VAV-2-1EF-2 VAV-1-3 VAV-2-1 VAV-1-1G22/22E12255B10270EF-1E12255G22/2 2G22/2218"x16"AC-1CU-1HP-1 TTTTTT G22/22A10240 16"x12"20"x12" 2233L6/66L6/6L6/6155188555585G22/2254771 16"x12"8G22/22516"x12"TCCP16"x12"820"x12 "810"x8"816"x16"8 VAV-1 BHP-210910 VAV-2B 14"x14"18"x18"AHU-2 16"x14"2340"x18"40"x18"11111111121313141 51515100101102103104104B1051061071081091 1011111211411311511811611711912016 1/8" = 1'-0" MECHANICAL floor PLAN8'1/8"=1'-0"08'16' #1 EQUIPMENT AND DUCTWORK ROUTED IN PLENUM SPACE BELOW LINES SUPPORT ON AND CLAMP TO UNI-STRUT CHANNEL ANCHOREDTO PAD 48" PAINT ELECTROMETRIC INSULATION WITH TWO COATS UV RATEDPAINT.