Example: marketing

Medi ltage Single Conductor 5 35

March 5, 2018 2018 CME Wire and Cable, Inc. All Rights Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | Voltage Cables - Single ConductorConductor Size AWG/kcmil2001 5000 V5001 35000 V90 C105 C90 C105 CMV-90MV-105MV-90MV-10585561 6758483934971101101202130145150165115517 51701901/0 1802001952152/0 2052252252553/0 2402702602904/0 2803052953302503153553303653503854303954 4050047553048053575060066558565510006907 70675755 NEC Table (C)(73) Ampacities of an Insulated Triplexed or Three Single Conductor Copper Cables in Isolated Conduit in Air Based on Conductor Temperatures of 90 C (194 F)

Aluminum NEC Table 310.60(C)(74) Ampacities of an Insulated Triplexed or Three Single Conductor Aluminum Cables in Isolated Conduit in Air Based on Conductor Temperatures of 90 °C (194 °F) and 105 °C (221 °F) and Ambient Air Temperature of 40 °C (104 °F)*

Tags:

  Aluminum, Conductor, Aluminum conductor

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Medi ltage Single Conductor 5 35

1 March 5, 2018 2018 CME Wire and Cable, Inc. All Rights Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | Voltage Cables - Single ConductorConductor Size AWG/kcmil2001 5000 V5001 35000 V90 C105 C90 C105 CMV-90MV-105MV-90MV-10585561 6758483934971101101202130145150165115517 51701901/0 1802001952152/0 2052252252553/0 2402702602904/0 2803052953302503153553303653503854303954 4050047553048053575060066558565510006907 70675755 NEC Table (C)(73) Ampacities of an Insulated Triplexed or Three Single Conductor Copper Cables in Isolated Conduit in Air Based on Conductor Temperatures of 90 C (194 F)

2 And 105 C (221 F) and Ambient Air Temperature of 40 C (104 F)*Rating VoltageMinimum Size AWG5 kV88 kV615 kV225 kV135 kV1/0 Conductor Size AWG/kcmil2001 5000 V5001 35000 V90 C105 C90 C105 CMV-90MV-105MV-90MV-10584348 6586565724768584942100115115130112013513 01501/0 1401551501702/0 1601751752003/0 1902102002254/0 2152402302602502502802552903503053403103 5050038042538543075049054548554010005806 45565640 Ampacity DataMedium Voltage Single Conductor 5 kV 35 kV MV Cable CopperMV Cable AluminumNEC Table (C)(74) Ampacities of an Insulated Triplexed or Three Single Conductor aluminum Cables in Isolated Conduit in Air Based on Conductor Temperatures of 90 C (194 F) and 105 C (221 F) and Ambient Air Temperature of 40 C (104 F)* 2018 CME Wire and Cable, Inc.

3 All Rights 5, 2018 CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | DataMV Cable CopperConductor Size AWG/kcmil2001 5000 V5001 35000 V90 C105 C90 C105 CMV-90MV-105MV-90MV-10586574 6909910011041201301301402160175170195118 52051952251/0 2152402252552/0 2502752602953/0 2903203003404/0 3353753453902503754153804303504655154705 2550058064558065075075083573082010008809 80850950 NEC Table (C)(67) Ampacities of Insulated Single Copper Conductor Cables Triplexed in Air Based on Conductor Temperatures of 90 C (194 F) and 105 C (221 F) and Ambient Air Temperature of 40 C (104 F)* Conductor Size AWG/kcmil2001 5000 V5001 35000 V90 C105 C90 C105 CMV-90MV-105MV-90MV-10585057 6707775844901001001102125135130150114516 01501751/0 1701851752002/0 1952152002303/0 2252502302654/0 2652902703052502953253003353503654053704 1550046051046051575060066559066010007158 00700780MV Cable AluminumNEC Table (C)(68) Ampacities of Insulated Single aluminum Conductor Cables Triplexed in Air Based on Conductor Temperatures of 90 C (194 F) and 105 C (221 F) and Ambient Air Temperature of 40 C (104 F)*NEC Table (C)(4)

4 Ambient Temperature Correction FactorsFor ambient temperatures other than 40 C (104 F), multiply the allowable ampacities specified in the ampacity tables by the appropriate factor shown ( C)Temperature Rating of ConductorAmbientTemperature( F)90 C 105 C10 or less or less 11 5916 6821 7726 8631 9536 10441 11346 12251 13156 14061 14966 15871 16776 17681 18586 90 19491 95 20396 100 212 Medium Voltage Single Conductor 5 kV 35 kV, Ampacity DataTechnical Data