Medical Device Directive 93/42/EEC CE-Marking …

Medical Device Directive 93/42/EEC . CE-Marking What Manufacturers Need to Know & Do By: Yvonne Halpaus QNET LLC. Conformity with Medical Device Directive 93/42/EEC . is mandatory all devices that fit the definition of a Medical Device ' and its This Directive is in the process of being replaced by a Regulation. Approval of the Regulation remains pending. Before starting the compliance immunological or metabolic means, but which may process a manufacturer needs to be be assisted in its function by such means;. able to answer the following four or basic questions: b) accessory' means an article which whilst not 1) Does the Device meet one of following 2 being a Device is intended specifically by its definitions? manufacturer to be used together with a Device to a) Medical Device ' means any instrument, enable it to be used in accordance with the use of apparatus, appliance, software, material or the Device intended by the manufacturer of the other article, whether used alone or in Device .

Copyright © 2015 QNET LLC – All Rights Reserved- Version 1 Page 2 3) What is the device risk classification? The determination of a device risk classification

Tags:

  Devices, Medical, Directive, Marking, Medical device directive 93 42, Ce marking

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Medical Device Directive 93/42/EEC CE-Marking …

1 Medical Device Directive 93/42/EEC . CE-Marking What Manufacturers Need to Know & Do By: Yvonne Halpaus QNET LLC. Conformity with Medical Device Directive 93/42/EEC . is mandatory all devices that fit the definition of a Medical Device ' and its This Directive is in the process of being replaced by a Regulation. Approval of the Regulation remains pending. Before starting the compliance immunological or metabolic means, but which may process a manufacturer needs to be be assisted in its function by such means;. able to answer the following four or basic questions: b) accessory' means an article which whilst not 1) Does the Device meet one of following 2 being a Device is intended specifically by its definitions? manufacturer to be used together with a Device to a) Medical Device ' means any instrument, enable it to be used in accordance with the use of apparatus, appliance, software, material or the Device intended by the manufacturer of the other article, whether used alone or in Device .

2 Combination, including the software intended 2) Who is the manufacturer? by its manufacturer to be used specifically The definition of a manufacturer is stated as follows: for diagnostic and/or therapeutic purposes manufacturer' means the natural or legal person and necessary for its proper application, with responsibility for the design, manufacture, intended by the manufacturer to be used for packaging and labelling of a Device before it is human beings for the purpose of: placed on the market under his own name, diagnosis, prevention, monitoring, treatment regardless of whether these operations are carried or alleviation of disease, out by that person himself or on his behalf by a third diagnosis, monitoring, treatment, alleviation party. of or compensation for an injury or handicap, investigation, replacement or modification of In plain English, if you place your company name the anatomy or of a physiological process, on the Device or label, you are the manufacturer.

3 __ control of conception, Only one name is allowed and is to be preceded by and which does not achieve its principal intended the EU Symbol for manufacturer. action in or on the human body by pharmacological, Copyright 2015 QNET LLC All Rights Reserved- Version 1 Page 1. 3) What is the Device risk classification? Starting the compliance process The determination of a Device risk classification must be justified on a risk rule found in Annex IX of Directive Article 11 titled: Conformity assessment the Directive and/or its support documents meddev procedures provides the options available based on latest Rev and the Border Line manual latest the Risk Classification of the Device , provided they version. are not custom made or intended for a clinical investigation: There are 6 risk classifications not to be compared with the US-FDA classifications: Risk Class III devices : Annex II or III coupled with Annex IV or Annex V.

4 A) Risk Class I, Note: this is the only classification that qualifies for Risk Class IIa devices : the self-certification compliance route in the Annex VII coupled with Annex IV or Annex V or Directive . Annex VI or Annex II. b) Risk Class I plus measuring function Risk Class IIb devices : c) Risk Class I plus sterilization Annex II (minus point 4) or Annex III coupled with d) Risk Class IIa Annex IV or Annex V or Annex VI. e) Risk Class IIb f) Risk Class III It is recommended that you discuss the preferred annexes with your Notified Body of choice. A recent Risk Classifications b) through f) all require study shows that a majority of Notified Bodies prefer assessment and certification by a European Notified use of Annex II coupled with one of the other Body. Annexes. Notified Bodies are for profit certification agencies In plain English, compliance requires an 1) Quality that charge for their services. Only European Management System (ISO 13485); 2) Technical file, agencies can be Notified Bodies.

5 Including a design file for the highest risk classifications; 3) Hiring of a Notified Body for 4) Guidance documents for Medical Device assessment and certification; 4) Appointing of an Directive 93/42/EEC EU authorized representative for regulatory affairs not sales and marketing (see: Harmonized European Standards, available for a ) ). fee. They are considered the state of the art', and are considered not mandatory' but in reality you will Risk Class I devices : Annex VII. be unable to ce-mark a Device without the use of harmonized EU standards. Use of non-EU A special note about Risk Class I Device CE. standards is possible only in the absence of an EU compliance standard. The compliance requirements for Risk Class I. EU Meddev documents available at no cost devices far exceed what is required by the US- FDA. Consensus statements no cost The manufacturer shall: Notified Body Operations Group (NBOG) 1) Compile a technical file, using EU standards, documents no cost which needs to include the following documentation: a) Classification justification.

6 Once you have determined that: 1) the product is a b) General Information about Device and Medical Device , 2) your company is the suppliers and sub-contractors;. manufacturer, 3) Device risk classification and have c) Translated Labels and Instructions for use located the 4) applicable support documents, you and use of EU Symbols;. are ready to start the compliance process. d) Risk assessment in accordance with ISO14971 latest issue;. Copyright 2015 QNET LLC All Rights Reserved- Version 1 Page 2. [Date]. e) Essential requirements may include - Membership in the Notified Body biocompatibility, flammability, EMC/LVD, Operations Group. software standards and other test reports; f) Evaluation of clinical data;. g) Procedures: for vigilance, post marketing In plain English, EU Notified Bodies are for profit review, translations etc. agencies, not government agencies. Their 3 year h) Declaration of Conformity; etc. contracts are not negotiable and transfer to another Notified Body has been made very expensive and 2) Appoint an EU authorized representative, who difficult.

7 Shopping for a Notified Body is impossible must register the devices in the EU and keep the because their application form contains text limiting technical file available to the Competent Authorities. application to one Notified Body only. ( ). We strongly recommend that you obtain references Selecting a Notified Body from other manufacturers and especially your Every manufacturer creates its own criteria, some of supplier/vendors before making a decision. the Notified Body (NB) criteria that turned out to be the very important to US manufacturers (often in Special Notes: hindsight) includes: Electrical/Electronic Medical devices must - Accreditation in the EU and Canada, if also comply with the Rohs Directive . This you export to Canada, does not require Notified Body certification. - Accreditation to include the Control the Device performance claims in manufacturer's specific Medical devices . marketing and online brochures, as this - Accepts English language technical files.

8 May cause a change in (higher) Risk - Has auditors that can explain the Classification. requirements in American English and Unannounced auditors cannot be turned are domiciled in the USA. away due to personnel vacations etc. Make - Accept manufacturer's crucial sure you have a backup team. suppliers/vendors ISO 13485 certificates The often misunderstood words shall' and issued by other EU Notified Bodies. should' in the Directive text stands for - Auditors trained to include good people must'. skills. Yes translations are required. - Have accreditation in directives that can cover other than Medical devices for a QNET LLC is a quality assurance and CE. specific manufacturer IVDD, compliance consulting firm specializing in cost Machinery and PPE etc. effective ce marking in accordance with Medical - Have a reasonable Notified Body Device , Rohs, PPE, Machinery, ATEX and Pressure transfer policy Equipment Directives since 1996.

9 Update: - Have the capacity and scope to Accept new clients/ devices . QNET BV Netherlands - delivers EU Authorized a) EU Notified Bodies shall: Representative services in accordance with the - Be an accredited EU based agency Medical , Machinery, PPE, RoHS, Medical and IVD. - Adhere to the: IAF MD9:2011 Mandatory directives since 1997. Document for the Application of ISO/IEC17021 in Medical Device Quality QNET LLC. Management Systems (ISO13485). PO Box 527. - Meet the requirements outlined in the Elk River, MN 55330 USA. Medical Device Directive . Phone: 763-441-0899. - Offer 3 year agreements consisting of: 1 Email: assessment certification audit, annual maintenance audits and unannounced audits Copyright 2015 QNET LLC All Rights Reserved- Version 1 Page 3.