MELSEC iQ-F FX5UC CPU Module Hardware Manual

MELSEC iQ-F FX5UC CPU ModuleHardware ManualThis Manual describes the part names, dimensions, installation, cabling andspecifications for the product. This Manual is extracted from MELSEC iQ-FFX5UC User's Manual ( Hardware ). Refer to MELSEC iQ-F FX5UC User'sManual ( Hardware ) for more details. Before use, read this Manual andmanuals of relevant products fully to acquire proficiency in the handling andoperating the product. Make sure to learn all the product information, safetyinformation, and , store this Manual in a safe place so that you can take it out and read itwhenever necessary.

MELSEC iQ-F FX5UC CPU Module Hardware Manual This manual describes the part names, dimensions, installation, cabling and specifications for the product.

Tags:

  Manual, Hardware, Module, Melsec, Fx5uc, F fx5uc cpu module hardware manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of MELSEC iQ-F FX5UC CPU Module Hardware Manual

1 MELSEC iQ-F FX5UC CPU ModuleHardware ManualThis Manual describes the part names, dimensions, installation, cabling andspecifications for the product. This Manual is extracted from MELSEC iQ-FFX5UC User's Manual ( Hardware ). Refer to MELSEC iQ-F FX5UC User'sManual ( Hardware ) for more details. Before use, read this Manual andmanuals of relevant products fully to acquire proficiency in the handling andoperating the product. Make sure to learn all the product information, safetyinformation, and , store this Manual in a safe place so that you can take it out and read itwhenever necessary.

2 Always forward it to the end : Ethernet is a trademark of Xerox Corporation. MODBUS is aregistered trademark of Schneider Electric SA. The company name and theproduct name to be described in this Manual are the registered trademarks ortrademarks of each April 2015 Specifications are subject to change without notice. 2015 MITSUBISHI ELECTRIC CORPORATIONS afety Precaution (Read these precautions before use.)This Manual classifies the safety precautions into two categories: and .Depending on the circumstances, procedures indicated by mayalso cause severe is important to follow all precautions for personal NumberJY997D61001 RevisionBDateApril 2015 Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe that incorrect handling may cause hazardous conditions, resulting in minor or moderate injury or property AND MAINTENANCE PRECAUTIONS Do not touch any terminal while the PLC's power is so may cause electric shock or malfunctions.

3 Before cleaning or retightening terminals, cut off all phases of the powersupply externally. Failure to do so in the power ON status may causeelectric shock. Before modifying the program in mid-operation, forcing output, running orstopping the PLC, read through this Manual carefully, and ensurecomplete operation error may damage the machinery or cause accidents. Do not change the program in the PLC from two or more peripheralequipment devices at the same time. ( from an engineering tool and aGOT)Doing so may cause destruction or malfunction of the PLC AND MAINTENANCE PRECAUTIONS Use the battery for memory backup in conformance to the MELSEC iQ-FFX5UC User's Manual ( Hardware ).

4 - Use the battery for the specified purpose Connect the battery Do not charge, disassemble, heat, put in fire, short-circuit, connect reversely, weld, swallow or burn the battery, or apply excessive force (vibration, impact, drop, etc.) to the Do not store or use the battery at high temperatures or expose to direct Do not expose to water, bring near fire or touch liquid leakage or other contents handling of the battery may cause excessive heat, bursting,ignition, liquid leakage or deformation, and lead to injury, fire or failuresand malfunction of facilities and other AND MAINTENANCE PRECAUTIONS Do not disassemble or modify the so may cause fire, equipment failures, or repair, contact your local Mitsubishi Electric representative.

5 Turn off the power to the PLC before connecting or disconnecting anyextension to do so may cause equipment failures or malfunctions. Turn off the power to the PLC before attaching or detaching the to do so may cause equipment failures or Peripheral devices, and expansion adapter- Extension modules, bus conversion Module , connector conversion Module , and batteryDISPOSAL PRECAUTIONS Please contact a certified electronic waste disposal company for theenvironmentally safe recycling and disposal of your device. When disposing of batteries, separate them from other waste according tolocal regulations.

6 (For details on the Battery Directive in EU countries, refer to the MELSECiQ-F FX5UC User's Manual ( Hardware ).)TRANSPORTATION PRECAUTIONS When transporting the PLC with the optional battery, turn on the PLCbefore shipment, confirm that the battery mode is set in PLC parametersand the BAT LED is OFF, and check the battery the PLC is transported with the BAT LED ON or the battery exhausted,the battery-backed data may be lost during transportation. The PLC is a precision instrument. During transportation, avoid impactslarger than those specified in the general specifications (Section ) byusing dedicated packaging boxes and shock-absorbing palettes.

7 Failure todo so may cause failures in the transportation, verify operation of the PLC and check for damage ofthe mounting part, etc. When transporting lithium batteries, follow required transportationregulations.(For details on the regulated products, refer to the MELSEC iQ-F FX5 UCUser's Manual ( Hardware ).)Associated manualsAssociated manualsFX5UC CPU Module comes with this document ( Hardware Manual ).For a detailed explanation of the FX5UC CPU Module Hardware andinformation on instructions for PLC programming and intelligent functionmodule, refer to the relevant of UL, cUL standardsPlease consult with Mitsubishi Electric for information on UL, cUL standardpractices and the corresponding types of with EC directive (CE Marking)

8 This document does not guarantee that a mechanical system including thisproduct will comply with the following to EMC directive of the entire mechanical system should bechecked by the user/manufacturer. For more details please contact the localMitsubishi Electric sales This product is designed for use in industrial Authorized Representative in the European Community:Mitsubishi Electric Europe Str. 8, 40880 Ratingen, GermanyCaution for compliance with EC DirectiveInstallation in EnclosureProgrammable controllers are open-type devices that must be installed andused within conductive control boxes.

9 Please use the FX5UC programmablecontrollers while installed in conductive shielded control boxes. Please securethe control box lid to the control box (for conduction). Installation within a controlbox greatly affects the safety of the system and aids in shielding noise from theprogrammable other cautions, refer to the MELSEC iQ-F FX5UC User's Manual ( Hardware ).Incorporated ItemsCheck if the following product and items are included in the package:1. Part names How to obtain manualsFor the necessary product manuals or documents, consult with your local Mitsubishi Electric nameManual iQ-F FX5 User's Manual (Startup)JY997D58201 Explains performance specifications, procedures before operation, and troubleshooting of the FX5 CPU iQ-F FX5UC User's Manual ( Hardware )JY997D61401 Explains FX5UC CPU Module specification details for I/O, wiring, installation, and iQ-F FX5 User's Manual (Serial Communication)JY997D55901 Explains the N.

10 N network, MELSEC Communication protocol, inverter communication and non-protocol iQ-F FX5 User's Manual (MODBUS Communication)JY997D56101 Explains the MODBUS serial iQ-F FX5 User's Manual (Ethernet Communication)JY997D56201 Functions for communication via built-in Ethernet Items CPU moduleFX5UC-32MT/DProduct1 moduleFX2NC-100 MPCB [1 m (3'3"), three wire]1 cableFX2NC-100 BPCB [1 m (3'3"), two wire]1 cableManuals [Japanese/English]1 manualManuals [Chinese]1 manualFX5UC-32MT/DSSP roduct1 moduleFX2NC-100 MPCB [1 m (3'3"), three wire]1 cableManuals [Japanese/English]1 manualManuals [Chinese]1 Manual I/O moduleFX5-C32EX/DFX5-C32ET/DProduct1 moduleFX2NC-10 BPCB1 [ m ( "), double-ended]1 cableFX5-C32EX/DSFX5-C32ET/DSSFX5-C32 EYT/D(SS)