Example: biology

MENU CLICK HERE TO GO TO TABLE OF CONTENTS

menu CLICK here TO GO TO TABLE OF CONTENTS . menu . TABLE of CONTENTS CLICK TOP OF ANY PAGE TO RETURN TO TABLE OF CONTENTS . DESCRIPTION PAGE. Cylinder Exchange 2. Gases, Gas Gas Welding and Cutting Gas Welding and Brazing Consumables (Rods/Fluxes)..7. Gas Welding and Cutting Equipment Ships Cabinet (Safety Charts)..9. AMEROX Equipment Identification Calibration/Span Gas ..13. Medical Oxygen Gas ..14. AMERARC Equipment Identification Arc Welding Equipment Ships Cabinet ..17. Arc Welding Arc Welding Machines Inverters AMERARC I-401 MST Inverter Arc Welding AMERARC I-401S Inverter Arc Welding AMERARC I-150 Inverter Arc Welding AMERARC TIG Welding Torch Head & Accessories TIG Welding AMERARC Plasma Cutting Arc Welding Equipment and AMERARC Gouging Torch.

CYLINDER EXCHANGE POLICY SALES - EXCHANGE – REDEMPTION NOTICE: The key elements of the cylinder policy are summarized below. This summary is intended as a quick reference and not a statement of policy. For

Tags:

  Menu, Content, Table, Here, Menu click here to go to table of contents, Click

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MENU CLICK HERE TO GO TO TABLE OF CONTENTS

1 menu CLICK here TO GO TO TABLE OF CONTENTS . menu . TABLE of CONTENTS CLICK TOP OF ANY PAGE TO RETURN TO TABLE OF CONTENTS . DESCRIPTION PAGE. Cylinder Exchange 2. Gases, Gas Gas Welding and Cutting Gas Welding and Brazing Consumables (Rods/Fluxes)..7. Gas Welding and Cutting Equipment Ships Cabinet (Safety Charts)..9. AMEROX Equipment Identification Calibration/Span Gas ..13. Medical Oxygen Gas ..14. AMERARC Equipment Identification Arc Welding Equipment Ships Cabinet ..17. Arc Welding Arc Welding Machines Inverters AMERARC I-401 MST Inverter Arc Welding AMERARC I-401S Inverter Arc Welding AMERARC I-150 Inverter Arc Welding AMERARC TIG Welding Torch Head & Accessories TIG Welding AMERARC Plasma Cutting Arc Welding Equipment and AMERARC Gouging Torch.

2 31. Central Gas Installation Systems (CGI)..33. Refrigerants, Test and Charging Work Safety Gas, Refrigeration & Welding References for Shipboard 43. Product 45. AMEROX Gas Welding & AMERARC . Cutting Products Arc Welding Products Gases Oxygen, Acetylene, Arc Welding Machines and Equipment Argon and Nitrogen Electrodes and Accessories Gas Welding and Cutting Equipment Plasma Cutting Systems Central Gas Installation Systems TIG Welding Equipment, Gas Welding and Brazing Consumables Consumables and Accessories Ships Cabinet Ships Cabinet menu . Cylinder Exchange Policy CYLINDER EXCHANGE POLICY ALTERNATIVE 3. SALES - EXCHANGE REDEMPTION Vessel Desires to Return Excess Cylinders, and the: NOTICE: The key elements of the cylinder policy are summarized below.

3 This A. Number of Returned Cylinders Equals the Number of Cylinders summary is intended as a quick reference and not a statement of policy. For Purchased From Drew Marine DURING Preceding Twelve Months. If empty full details as well as terms and conditions, please refer to the Drew Marine cylinders to be returned are more than the quantity of full cylinders supplied to Delivery Receipt which shall apply for all transactions. the vessel, the customer's account will be credited with a redemption value for excess cylinders returned equal to the original purchase price, less for each day that the cylinder has been in the customer's possession provided that the number of returned cylinders does not exceed fine number of cylinders GENERAL which have been purchased from Drew Marine within the preceding twelve All cylinders are sold to the customer Incoterms 2010 FAS at normal ports of (12) months.

4 Storage. Complete ownership of the cylinder is transferred to the customer at B. Number of Returned Cylinders Exceeds the Number of Cylinders that time and place. Purchased from Drew Marine Prior to Preceding Twelve Months. Drew Drew Marine will accept cylinders for exchange or for return which are marked Marine will accept the cylinders and credit line customer's account with a Drew Marine, or which meet the following specifications. redemption value for the excess cylinders originally purchased from Drew Marine prior to the last twelve (12) months based on the original purchase Oxygen, Argon and Nitrogen price, less the following reduction schedule: BS 5045-7 and DOT-3 AA-2132 or UN/ISO 9809-1, -2, -3. Reduction From Acetylene Length of Possession Current Drew Marine List Price BS 5045 or UN/ISO 3807-2 and UN/ISO 9809-1, -3.

5 1-2 years 50%. Drew Marine accepts no responsibility for non-standard cylinders being landed 2-3 years 65%. without prior consent in writing. 3-4 years 70%. Drew Marine will provide normal cylinder maintenance including periodic hydrostatic inspection and recertification and replacement of worn top valves 4-5 years 75%. at no cost to the ship owner. The repair of any damages caused by misuse or 5-6 years 80%. improper handling by the customer or missing valve protection caps will be 6-7 years 85%. charged to the account of the ship owner. 7-8 years 90%. Drew Marine will not accept for credit cylinders which have been subjected to arc burn, flame, fire or impact resulting in dents or gouges. 8- years and over 95%. C. Cylinders Presented for Redemption Were Not Originally Purchased from Oxygen, Acetylene, Nitrogen and Argon Cylinders Drew Marine.

6 Drew will credit the customer's account for the return of excess ALTERNATIVE 1 cylinders in acceptable condition which were not originally purchased from Drew Vessel Returns Cylinders for Exchange for an amount equal to fair market value. Empty cylinders returned from the vessel will be exchanged for an equal LIMITATIONS ON RETURNS OF ALL CYLINDERS. number of full cylinders supplied by Drew Marine. Customer is only invoiced for Cylinders may be returned at any Drew primary port of storage as listed in the the contained gas. current Drew Port Directory. ALTERNATIVE 2. In order to maintain a balanced cylinder stock, Drew reserves the right to Vessel Requires Additional Cylinders designate alternate ports where cylinders can be returned. If the number of empty cylinders returned is less than the number of full cyl- IMPORTANT NOTICE: Drew Marine warrants that GOODS delivered hereunder inders supplied to the vessel, the customer will be invoiced for the additional meet Drew Marine's specifications.

7 This is Drew Marine's sole warranty with cylinders supplied as well as the contained gas product provided in all cylinders. respect to the GOODS. ALL OTHER WARRANTIES, OTHER THAN TITLE, EITHER. EXPRESS OR IMPLIED, WHETHER ARISING UNDER LAW OR EQUITY OR CUSTOM. OF TRADE, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS. FOR A PARTICULAR PURPOSE, ARE EXCLUDED FROM THIS AGREEMENT. All statements information and data presented herein are believed to be accurate and reliable but are not to be taken as a guarantee express warranty or implied warranty of merchantability or fitness for a particular purpose, or representation, express or implied for which seller assumes legal responsibility and they are offered solely for your consideration, investigation and verification.

8 Statements or suggestions concerning possible use of this product are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe on any patent. 2. menu . AMEROX Gases and Gas Cylinders TECHNICAL INFORMATION (Some cylinders may vary from these norms. Refer to cylinder shoulder stampings prior to refilling.). OX 40 OX5 AC 40 AC5. Cylinder PCN 0506016 0720012 0507014 0722018. Gas Charge PCN 0505018 0721010 0504010 0723016. CYLINDER TYPE OX 40 OX5 AC 40 AC5. Cylinder Capacity (water) Liters Typical Weight/Cylinder Gross Weight kg (lbs) with Valve and Cap ( ) ( )W ( ) ( ). Nominal Tare Weight kg (lbs) ( ) ( ) . TARE S (Acetylene only) (*) ( ) TARE ( ). Nominal Cylinder Dimensions Diameter mm 229 140 229 140.

9 Height With Cap mm 1350 590 1350 590. Valve Outlet Connection Whitworth mm 1/14 RH Ext Whitworth mm 1/14 RH Int Forged Brass with Nickel Bursting Valve Type Forged Brass Disc Cylinder Color Blue RAL 5009 Maroon RAL 3011. BS 5045-7 and DOT 3AA-2132 or BS 5045 with Porous Massing to UN/. Cylinder Approvals UN/ISO 9809 -1, - 2, - 3 ISO 3807-2 or UN/ISO 9809-1 or -3. Visual inspection at each refill, Cylinder Retest Period 5 yrs. or specific country requirement 10-yr. mass inspection Acetone content Acetylene Cylinder kg (lbs) (276) ( ). Cylinder Product content Standards @ 15 C, 1 ATU. Cubic Meters Cubic Feet kg (lbs) ( ) ( ) ( )(**) ( ). Cylinder Equilibrium Pressure After Filling @ 15 C. BAR PSIG kg/CM2 Cylinder Test Pressure @ 15 C - BAR (PSI) (3815) (3815) (1088) (1088).

10 Maximum Recommended Continuous Withdrawal N/A N/A 1000 125. Rate Per Cylinder, Liters/Hour (*) TARE S for acetylene cylinders includes cylinder shell, neck ring, top valve, porous mass, acetone and saturation charge. (**) Some non-Drew marked cylinders may be limited to kg filling weight. Residual Pressure Valves The Drew Marine AMEROX Cylinder label has always included the statement RETURN WITH 1 BAR PRESSURE as well as Keep valve closed at all times when not in use. These instructions are not always followed and occasionally cylinders are returned that have been exposed to salt water with the top valves open. Water inside a cylinder can result in serious internal corrosion, in the case of an oxygen cylinder, or a significant reduction in the capacity of an acetylene cylinder.


Related search queries