UNITED F OR WATER QU ALIT YMET ONE 3400 Series Portable Airborne Particle CounterPRODUCT INFORMATIONCLEANROOM ANALYSISAIR Particle COUNTERMET ONE 3400 SERIESThe MET ONE 3400 also features multi-level user login capability, 21 CFR Part 11 compliance, easy data down-load, strategically placed carrying hand-les and an easy-to-wipe down stainless-steel flexible communication options and open communication architecture, the MET ONE 3400 Particle Counter can seamlessly integrate into a central envi-ronmental monitoring system eliminating the need for any paper work. Intuitive operating commands and test wizard rich user interface software, featuring regulatory standard compliant reporting functions, Long Life Laser technology and long continuous operation capability enables the MET ONE 3400 to reliably perform validation testing and critical process monitoring for cleanrooms.

UNITED FOR WATER QUALITY MET ONE 3400 Series Portable Airborne Particle Counter PRODUCT INFORMATION CLEANROOM ANALYSIS AIR PARTICLE COUNTER

Tags:

  Series, Portable, Particles, Counter, 4300, Airborne, Particle counter, 3400 series portable airborne particle counter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MET ONE 3400 Series Portable Airborne Particle Counter

1 UNITED F OR WATER QU ALIT YMET ONE 3400 Series Portable Airborne Particle CounterPRODUCT INFORMATIONCLEANROOM ANALYSISAIR Particle COUNTERMET ONE 3400 SERIESThe MET ONE 3400 also features multi-level user login capability, 21 CFR Part 11 compliance, easy data down-load, strategically placed carrying hand-les and an easy-to-wipe down stainless-steel flexible communication options and open communication architecture, the MET ONE 3400 Particle Counter can seamlessly integrate into a central envi-ronmental monitoring system eliminating the need for any paper work. Intuitive operating commands and test wizard rich user interface software, featuring regulatory standard compliant reporting functions, Long Life Laser technology and long continuous operation capability enables the MET ONE 3400 to reliably perform validation testing and critical process monitoring for cleanrooms.

2 Flexible communications Wireless, Ethernet, Serial and USB Test wizard for easier compliance Seamless connectivity to data management :52 compliance, saving valuable operator timeAIR Particle COUNTER_MET ONE 3400 SERIESNow with Ethernet, Wireless, Serial and manifold supportFlexible communication options such as Wireless, Ethernet, Serial and manifold connectivity reduce installation time and cost for the MET ONE 3400 by utilizing existing communication network infra-structures. Test wizard for easier complianceMET ONE 3400 Series Portable Particle counters now have a simple-to-use test wizard and offer the necessary docu-mentation to help you comply with ISO, FDA and EU standards - saving operator time in planning, sampling and proces-sing raw count connectivity to data management softwareWith an open communication archi- tecture, the MET ONE 3400 can seamlessly be integrated into a central environmental monitoring system elimina-ting the need for manual record keeping.

3 The OPC server enabled communication architecture reduces cost of integration to commonly used industrial data management software. Unit-to-unit accuracy and reproducibilityDesigned for full ISO 21501-4 calibration compliance ensuring data accuracy and unit-to-unit channelsStraightforward selectable 8-channel option for easy filter user interface Easy area, location and operating para-meter configuration and replication saves operator time for setting and running the Counter . :52:43 Intuitive user interface with touchscreenHACH LANGE ServiceOn-site service, calibration support and service contracts to keep your equipment in compliance Providing quality serviceHACH LANGE service contracts keep your equipment in compliance and your operations at peak performance to minimize 3 ERVICE PARTNERSHIP PROGRAMS A INCLUSIVE AGREEMENTS FOR service and support.

4 S )N FACTORY SERVICES WARRANTY AND REPAIR check-up, calibration and service /N SITE SERVICES WARRANTY AND lELD REPAIR START UP AND installation services, training and preventive maintenance #USTOM SERVICE PROGRAMS FOR YOUR UNIQUE REQUIREMENTS 21 CFR Part 11 compliancePassword protected multi-level user access to instrument provides data security for 21 CFR Part 11 complianceLong continuous operationLong battery life between charges results in longer instrument availability. Hot-swappable batteries eliminate the need for powering down, zero counting and powering back upLong Life Laser Long Life Laser diode with 10-year MTTF reduces cost of ownershipManifold SupportSupport of MET ONE 2432 manifold provides low cost semi-continuous monitoring optionTechnical :52:44 HACH LANGE GMBHW illst tterstra e 11D-40549 D sseldorfTel.

5 +49 (0)2 11 52 88-0 Fax +49 (0)2 11 52 F OR WATER QU ALIT YTechnical dataAIR Particle COUNTER_MET ONE 3400 Series Standard size channels 3413 / 3423 , , , , , m 3415 / 3425 , , , , , or , , , , , m Flow rate 3413 / 3415 LPM ( CFM) 5 % 3423 / 3425 50 LPM ( CFM) 5 % Zero count Conforms to JIS B9921 1 count or less in 5 minutes, 95 % confidence level Coincidence loss LPM ( CFM) 5 % at 14,126,000 particles /m3 (400,000 particles /ft3) 50 LPM ( CFM) 5 % at 4,000,000 particles /m3 (113,266 particles /ft3) Counting efficiency 3413 / 3423 50 % 20 % for m, (100 % 10 % at times the minimum sensitivity), fully complies with ISO 21501-4 3415 / 3425 50 % 20 for m, (100 % 10 % at times the minimum sensitivity), fully complies with ISO 21501-4 Light source Long Life Laser Diode with greater than 10-year Mean Time To Failure (MTTF)

6 Pump type Air vacuum rated for continuous use Count display Color 1/4 VGA TFT touch screen Interface Windows CE -based Sample/Hold/Delay times 1 second to 23 hrs 59 min 59 sec Count alarms 1 to 9,999,999 counts Count cycles Up to 100 while in automatic mode Manifold Supports 2432 32-port manifold system Location labels 0 to 999, appears on printout Data storage 5,000 samples, scrollable on historical data review screen Communication interfaces RS232, RS485, b/g Wireless, Ethernet, USB Client (Version ), USB Host (Version ) Communication protocol Modbus TCP, Modbus RTU, Serial FX Battery type Lithium ion smart battery; rechargeable, ejectable and hot-swappable Operating time (battery) LPM ( CFM), 6 hours* 50 LPM ( CFM), 7 hours* Battery recharge time hours minimum, 10 hours maximum Power 24 VDC with 100~240 VAC 50/60 Hz adapter (included in ship kit) Dimensions W x D x H cm / x 10 x 8 inches Weight (without battery) 3413 / 3415: kg ( lbs).

7 3423 / 3425: kg ( lbs) Enclosure material Stainless steel Environment Operating: 0 to -40 C / 32 to 104 F, 10 to 90 % relative humidity, non-condensing Storage: -40 to 50 C / -40 to 122 F, 0 to 98 % relative humidity, non-condensing Warranty 2 years (instrument) ; 3 years (Long Life Laser diode) Accessories Included Isokinetic Probe (aluminum), Zero count filter, Nozzle cleaning brush, PortAll version 2 Trial software, Flash memory drive, AC adapter and power cord, 2 rolls printer paper, 1 lithium ion smart battery, Operator manual, cm ( ) hytrel tubing, Tripod, Isokinetic probe clamp, Stylus for touch screen Options Relative humidity / Temperature probe, PortAll version 2 software, Case with wheels and foam insert, Air velocity sensor, Second lithium ion smart battery Smart battery charger, Isokinetic probe (stainless steel)

8 , IQ/OQ Validation protocol, Non-electronic filter scanning probe, High pressure diffuser, Extra cm ( inches) Hytrel tubing, USB to RS-485 or USB to RS-232 converter MET ONE 2432 32-port Manifold, Selectable 8-channel option**, Wireless communication, OPC server When ordering, specify Basic sensitivity, selectable channel option, flow rate and wireless option* Battery life is estimated with these conditions: the cfm unit sampling for 20 minutes (1 m3) sample, print record, a 5-minute hold time (simulating move to new location), then repeat this cycle. Backlight sleep time is set at 2 minutes.

9 The cfm unit, sample time is set at one minute, print record, a 1-minute hold time (simulating continuous sampling mode), then repeat this cycle. Backlight would remain on at all times.** Channel selections can be selected at time of order in a range from m to 25 m. However m and 25 m cannot be configured LANGE ServicesContact us to place an order, request information or receive technical and workshops: Practical and hands on assurance, complete with standard solutions, instrument checks and test site technical :52:45