Example: air traffic controller

Metal Conduit Systems - MK Electric

Metal Conduit Systems Metal Conduit Systems Product Range Finder Range Product Pages rigid Conduits rigid Conduits 4. Accessories 5-8. Technical 9-11 Ega rigid Conduits Flexible Conduits Bare Flexible Conduits 13. PVC Coated Flexible Conduits 14. Adaptors 15. MK Flexible Conduits HONEYWELL MIDDLE EAST ELECTRICAL DEVICES & Systems . HEAD OFFICE. Telephone: +44 (0)1268 563000 Facsimile: +44 (0)1268 563405. HONEYWELL - ELECTRICAL DEVICES & Systems . The Arnold Centre, Paycocke Road Basildon Essex 5514 3EA UK Website: Regional Of ce (Middle East) Telephone: +971 4 807 3200 Facsimile: +971 4 881 5711. Honeywell ME, FZE. Box 18530, Jebel Ali, Dubai, Website: KSA Area Of ce Telephone: +966 1 218 0606 Facsimile: +966 1 218 0607. King Faisal Foundation Building Box 11554, Riyadh, KSA Website: Jeddah Of ce Telephone: +966 2 617 8114/7 Facsimile: +966 2 617 8277. 3rd Floor, Al-Awwad Commercial Bldg, Sitteen St, South to Bicycle Round Website: Qatar Area Of ce Telephone: +973 1721 5101 Facsimile: +974 442 3970.

4 5 Rigid Metal Conduits Heavy Gauge Conduit - Welded - Screwed Manufactured in accordance with BS 4568 Part 1: 1970 / BS EN / IEC 61386-1 :2008 where applicable.

Tags:

  System, Metal, Rigid, Conduit, Metal conduit systems, Rigid metal

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Metal Conduit Systems - MK Electric

1 Metal Conduit Systems Metal Conduit Systems Product Range Finder Range Product Pages rigid Conduits rigid Conduits 4. Accessories 5-8. Technical 9-11 Ega rigid Conduits Flexible Conduits Bare Flexible Conduits 13. PVC Coated Flexible Conduits 14. Adaptors 15. MK Flexible Conduits HONEYWELL MIDDLE EAST ELECTRICAL DEVICES & Systems . HEAD OFFICE. Telephone: +44 (0)1268 563000 Facsimile: +44 (0)1268 563405. HONEYWELL - ELECTRICAL DEVICES & Systems . The Arnold Centre, Paycocke Road Basildon Essex 5514 3EA UK Website: Regional Of ce (Middle East) Telephone: +971 4 807 3200 Facsimile: +971 4 881 5711. Honeywell ME, FZE. Box 18530, Jebel Ali, Dubai, Website: KSA Area Of ce Telephone: +966 1 218 0606 Facsimile: +966 1 218 0607. King Faisal Foundation Building Box 11554, Riyadh, KSA Website: Jeddah Of ce Telephone: +966 2 617 8114/7 Facsimile: +966 2 617 8277. 3rd Floor, Al-Awwad Commercial Bldg, Sitteen St, South to Bicycle Round Website: Qatar Area Of ce Telephone: +973 1721 5101 Facsimile: +974 442 3970.

2 Box 856. Doha - Qatar Website: Abu Dhabi Area Of ce Telephone: +971 2 4041377 Facsimile: +971 2 4432536. Box 45595 Website: Abu Dhabi, Registered Office: Honeywell House Arlington Business Park Bracknell Berkshire RG12 1EB Registered No. 189291 Ref MEMK0204-0412a-EN. Metal Conduit system Honeywell - Electrical Devices & Systems Our total commitment to customer service reflects the growing needs of specifiers, distributors and installers All marks in this document identified with a or symbol adjacent to the mark are Trade Marks of Honeywell ED&S Limited 1. Contents Range Product Pages rigid Conduits rigid Conduits 4. Accessories 5-8. Technical 9-11. Flexible Conduits Bare Flexible Conduits 13. PVC Coated Flexible Conduits 14. Adaptors 15. 2. rigid Conduits and Accessories Ega Brand rigid Conduits from MK Electric confidence. Manufactured from high quality offer a reliable solution for both new build steel, Ega rigid Conduits and Accessories are and refurbishment contracts.

3 The wide range capable of withstanding extreme conditions on of fittings and ancillary products means that site and exceeds the stringent requirements of almost any installation can be specified with established International Standards. 3. rigid Metal Conduits Heavy Gauge Conduit - Welded - Screwed Manufactured in accordance with BS 4568 Part 1: 1970 / BS EN / IEC 61386-1 :2008 where applicable. Each meter length screwed both ends and complete with one solid coupling. Part number External No. of lengths No. of bundles Metres Approx. weight Diameter per bundle per lift per lift per lift in Kg BS 4568 / BS EN / IEC 61386-1 :2008. Class 4 finish ERC 20/4 20mm 10 100 375 272. HOT DIPPED GALVANISED ERC 25/4 25mm 10 100 375 348. INSIDE & OUTSIDE ERC 32/4 32mm 5 25 metre lengths Above Conduit is packed and shipped in LIFTS (also known as Master Bundles). Conduits are threaded at both ends. Each LIFT comprises the stated number of individual bundles measuring One end fitted with coupling and the other protected by plastic end cap.

4 Approximately 45-50 cms and long. The weight varies according to For bigger size conduits, Please contact MK ME Office size and finish of Conduit . Dimensions Part No. Trade Size Outer Diameter Thickness Length of Threads Weight (g/m). (mm) Min Max Nominal Wall Min Max Min Max ERC 20 / 4 20 682 862. ERC 25 / 4 25 860 1095. ERC 32 / 4 32 1133 1432. 4. rigid Metal Conduits Fittings and Accessories Boxes Circular, Small Material: Malleable Iron Finishes: Galvanised mm Internal Diameter 20mm Boxes Minimum 25mm Deep 25mm Boxes Minimum 28mm Deep Tapped M4 at centres. With tapped hole in base for earthing screw. Supplied without covers or fixing screws unless ordered. ETR 01 ETE 01 ETR 02 ETE 02. ETH 01 EXX 01 ETH 02 EXX 02. EAG 01 EBO 02 EAG 02 EXV 01. ETR 01/-- 10 ETE 01 /-- 10 ETR 02 /-- 10 ETE 02 /-- 10. Terminal Boxes Tee Boxes Terminal Boxes with Back Outlet Tee Boxes with Back Outlet Available in 20mm & 25mm sizes. Available in 20mm & 25mm sizes. Available in 20mm & 25mm sizes.

5 Available in 20mm & 25mm sizes. ETH 01/-- 10 EXX 01 /-- 10 ETH 02 /-- 10 EXX 02 /-- 10. Through Boxes Cross Boxes Through Boxes with Back Outlet "Cross" Box with Back Outlet Available in 20mm & 25mm sizes. Available in 20mm & 25mm sizes. Available in 20mm & 25mm sizes. Available in 20mm & 25mm sizes. EAG 01/-- 10 EBO 02 /-- 10 EAG 02 /-- 10 EXV 04 /-- 10. Angle Boxes Back Outlet Boxes Angle Boxes with Back Outlet V BOXES. Available in 20mm & 25mm sizes. Available in 20mm & 25mm sizes. Available in 20mm & 25mm sizes. Available in 20mm & 25mm sizes. Note: Available in 20mm and 2 Smm sizes Please specify when ordering. Eg:- ETR 01 / 20 20mm Terminal Box. ETR 01 / 25 25mm Terminal Box. 5. rigid Metal Conduits Fittings and Accessories Boxes Looping In Screws Covers Circular Small Material: Steel Material: Steel Finishes: Galvanised *Malleable Iron With tapped hole in base for **Malleable Iron with copper earth wire earthing screw. Finishes: Galvanised 20mm clearance. EXY 01 EA 01 ESC 05 EAC 01.

6 EXH 01 EA 02 ESC 03 EAC 02. EAC 06. EXY 01/-- 10 EA 01/-- 10 ESC 05 100 EAC 01/-- 50. Three Way Branch Box Medium, Steel Brass, M4 Earth Terminal Studs Cover, Light, Overlapping, Available in 20mm & 25mm sizes 1 Hole or Knockouts Loose, No Screws. 29mm Deep x Internal Diameter Available in 20mm & 25mm sizes EXH 01/-- 10 EA 02/-- 10 ESC 03/-- 100 EAC 02/-- 50. Twin Through way 'H' Boxes Medium, Malleable Brass, Raised Countersunk Cover, Light, Loose, No Screws. Available in 20mm & 25mm sizes 1,2,3,4 Holes Available in 6mm, 10mm, 12mm,16mm, Available in 20mm & 25mm sizes Minimum 31mm Deep x Internal 20mm and 25mm sizes Diameter EAC 06/-- 10. Cover, Female Dome Available in 20mm & 25mm sizes 6. rigid Metal Conduits Fittings and Accessories Couplings Elbows Bends Washers Material: Steel Material: Malleable Iron Material: Steel Material: *Steel *20mm - 32mm Steel Cover *20mm - 32mm Steel Cover Finishes: *Self Colour, Zinc Plated Finishes: Galvanised Malleable Iron Cover Malleable Iron Cover Finishes: Galvanised Finishes: Galvanised EAC 12 EAC 18 EAC 20 EAC 22.

7 *EAC 19 *EAC 23. EAC 12/-- 50 EAC 18/-- 20 EAC 20/-- 20 EAC 22/-- 250. Coupling, Solid Elbow, Solid Bend, Normal, Internal Thread Lead No. E112, Neoprene Available in 20,25 & 32mm Available in 20mm & 25mm sizes Available in 20mm & 25mm sizes Available in 20mm & 25mm sizes Pack Qty is 10 for 25mm Pack Qty is 200 for 25mm EAC 19/-- 20 EAC 23/-- 250. Elbow, Channel Inspection Serrated No Available in 20mm & 25mm sizes Available in 20mm & 25mm sizes Pack Qty is 200 for 25mm Complete with washer and brass bush Neoprene washers effect a greater degree of protection from the ingrees of dust and/or liquids. Reference should be made to Publication 529 - 1976. Finishes: Galvanised M110 (Lead washer). M110 (Neoprene washer). 7. rigid Metal Conduits Fittings and Accessories Tees Bushes Reducers Saddles Material: Malleable Iron Material: Brass Material: Malleable Iron Material: Steel *20mm - 32mm Steel Cover Finishes: Self Colour Finishes: Brass Galvanised *Malleable Iron with Steel Top Malleable Iron Cover Finishes: Galvanised Finishes: Galvanised ERA 01 ERA 07 ERA 13 *ERS 02.

8 *ERA 02 ERA 08 ERS 03. ERS 05. ERA 01/-- 20 ERA 07/-- 50 ERA 13/25 Reducer ERS 02/-- 25. Tee, Solid Bush, Short Male Size (mm) 25x20 Saddle, Distance Available in 20mm & 25mm sizes Available in 20mm & 25mm sizes St'd Pack Qty 100 Available in 20mm & 25mm sizes Pack Qty is 10 for 25mm ERA 02/-- 20 ERA 08/-- 50 ERS 03/-- 100. Tee, Channel Inspection Bush, Long Male Saddle, Spacer Bar, One Way Available in 20mm & 25mm sizes Available in 20mm & 25mm sizes Available in 20mm & 25mm sizes Pack Qty is 10 for 25mm Pack Qty is 10 for 25mm ERS 05/-- 100. Saddle, 1 Way (Single). Available in 20mm & 25mm sizes 8. rigid Metal Conduits Technical E T H 01/--/ 10. EGA branded Series 2 Packed in sets 25mm boxes of or 1. Series 1 Series 3. Through boxes Size Terminal boxes TR Small boxes 01. Through boxes TH Small boxes with back entry 02. Tee TE Larger boxes 03. Cross XX. H XH. Series 2. U XU. Angle AG. Y XY. Back Outlet BO. Series 1. 20 - 20mm Fitting 25 - 25mm Fitting 32 - 32mm Fitting 38 - 11/2" or 38 Fitting 50 - 2" or 50mm Fitting Series 3.

9 9. rigid Metal Conduits Technical Cable Capacities of Conduit The following tables give guidance of the calculation of the number of single-core insulated cables which can be located in various sizes of Conduit . The tables deal with two particular cases: (i) Single-core insulated cables in straight runs not exceeding 3 meters in length (ii) Single-core insulated cables in straight runs exceeding 3 meters in length or in runs of any length with bends or sets STRAIGHT RUNS NOT EXCEEDING Sum all the cable factors and compare with the Conduit 3 METERS IN LENGTH factor given in Table 4 for the relevant length of run and the number of bends and sets in that run. For each type of cable being used obtain the cable factor from Table 1, Sum all the the cable factors and compare The Conduit sizes which will accommodate the cables are with the Conduit factors given in Table 2. those with a Conduit factor equal or greater than the sum of the cable factors. The Conduit sizes which will accommodate the cables are those with a Conduit factor equal to or greater thean the sum of the cable factors.

10 Type of Conductor Condutor cross-sectional area mm2 Factor Type of Conductor 1 16. Condutor cross-sectional Solid 22. area mm2 Factor or 30. Standard 4 43. 1 22. 6 58. Solid 27. Conduit Factor 10 105. 39. dia mm Table 3. 31. 43 16 290 SPACING OF SUPPORT FOR CONDUITS. Standard 4 58 20 460. 6 88 25 800 The following tables gives guidance on the spacing of 10 146 32 1400 supports for Conduit . Table 1 Table 2. Normal size Maximum distance between support of Conduit Horizontal runs Vertical runs STRAIGHT RUNS EXCEEDING 3 METERS IN LENGTH mm m m OR RUNS OF ANY LENGTH INCORPORATING BENDS. OR SETS 16mm 17mm - 25mm For each type of cable being used obtain the cable factor 26mm - 40mm from Table 3. Over 40mm Table 4. Table 1 Table 3. Cable factors for short straight run Cable factors for straight runs or runs incorporating bends Table 2 Table 4. Cable factors for short straight run This table is based on the 16th edition of Writing Regulations Appendix 11. These tables are based on the 16th edition of the These tables are for guidance only and Writing Regulations Appendix 12.