Transcription of METAL SHARK® 2 BD
1 Tectronix Systems Inc., 9 - 18812 96 Ave, Surrey BC, Canada, V4N 3R1PH: +1 604-607-6028, FAX +1 604-607-6026 shark 2 BDEnglish Operator s ManualNorth America2 METAL shark 2 BD Operator s ManualSoftware Version and higher3 Software Version and higherIndexIndex3. Safety Messages .. Safety Symbols and Definitions .. General Safety Instructions .. Safety Instructions for the METAL Detector .. Installation Instructions .. Connecting Instructions .. Instructions about Operation .. Protection against Interference ..94. Getting Started ..115. Introduction .. General Information .. Information about this Manual .. Content of this Manual .. Target Group for this Manual .. Typographic Conventions .. Scope of Application and Qualification.
2 Normal Use .. Misuse .. Owner s Obligation to Exercise Due Care .. Requirements for Operating Staff .. Requirements for Service and Maintenance Staff ..166. Technical Description .. Method of Operation .. Operating Limits .. Technical Data .. METAL Detector METAL shark 2 BD ..197. Transport .. Safety & Protection Instructions .. Lifting ..228. Mechanical Installation .. METAL -Free Zone .. Minimum Distance Between Motor and Sensor Head .. Gap Between Sensor Head and Product .. Vibrations .. Feed of Belt Through Sensor Head .. Mounting on Conveyor / Frame .. Keep Conveyor Belt Clean .. Welding of Transversal Struts and Contact Points .. Isolation of Drums and Shafts ..279. Electrical Terminals of Power Supply Board.
3 Relay K1, K2 - Function .. Terminals on the Mainboard ..314 METAL shark 2 BD Operator s ManualSoftware Version and Wiring Diagram Examples .. Belt Controls STR1 and STL1 .. Belt Controls STR2 and STL2 ..3310. Control Panel and Main Screens .. The Control Panel .. The Main Screens .. The Bar Graph's Screen The 2D Plot's Screen Elements .. The Scope's Screen Elements ..3911. Initial Parameter Setup (all types, except BIG pba) ..4112. Daily Operation Overview ..4311. Daily Operation .. PRODUCT Select & Edit Existing Products .. TEST Check METAL Detector's Performance .. TEACH Add New Product .. OPTIMIZE Improve Stability & Sensitivity .. Optimize with the Histogram .. Optimize with the 2D Plot.
4 5312. MENU Daily Operation Setup .. REPORT MENU .. IFS/HACCP REPORT .. METAL REPORT .. EVENT REPORT .. METAL COUNTER .. TOTAL COUNTER .. PRINT .. INTERFACE .. BAUDRATE RS232 .. SHARKNET UNIT # .. MAIN SCREEN .. HISTOGRAM LIMIT % .. INFO SOFTWARE .. TEST MENU .. PASSWORD (MENU) .. PRODUCT MENU ..6313. MENU General Settings .. PRODUCT MENU .. REJECT MENU .. TEACH SETUP .. ADVANCED (MENU) .. SYSTEM MENU .. DATE/TIME MENU .. AUTOSPEED MENU .. CIP MENU .. BRC MENU .. IN/OUT MENU .. FILTER MENU ..785 Software Version and FACTORY MENU ..8014. Trouble Shooting .. Error Messages .. Reset to Default Passwords and Language .. Factory Settings .. Problem Solving .. Problem: Still Considerable METAL Alarms After TEACH.
5 Problem: Still Few METAL Alarms After TEACH .. Problem: TEACH ends After Short Period of Time .. Problem: Poor METAL Sensitivity After TEACH ..8315. Maintenance and Regular Inspections .. Maintenance .. Regular Inspections .. Notes ..8516. Annex .. Declarations .. CE - Declaration of Conformity .. Declaration of Manufacturer ..88 Parameter List METAL shark 2 BD/ Software Version ..896 METAL shark 2 BD Operator s ManualSoftware Version and higher3. Safety Safety Symbols and DefinitionsIn this manual we use the following safety symbols. These symbols are supposed to draw the readers attention especially to the text next to the safety symbol. General Danger! This Symbol indicates that there is a potential danger for life and due to High Voltage!
6 This symbol indicates that there is a potential danger for health and life due to high voltage. Only qualified electricians are allowed to carry out tasks that are marked with this due to Moving Parts! This symbol indicates that exposed moving parts may injure your fingers or !This symbol indicates that there is a potential danger for machinery, material or the General Safety InstructionsDanger! Before working with the METAL detector read these safety instructions put the METAL detector into operation without the safety devices provided by the manufacturer. Only specially trained maintenance staff is allowed to operate the equipment without the safety down the machine immediately if the safety devices are not operating properly or if there are other apparent defects which pose a danger.
7 Any defects must be elim-inated or reported observe any warning signs attached to the machine. They help prevent dan-gerous situations. The removing of these warning signs is strictly put the METAL detector into operation yif you have not received complete initial training from the owner, yif you have not fully read the operating instructions or yif you have not fully understood the operating operating the machine correctly may result in severe injury or the area of the equipment is strictly prohibited for unauthorised persons. An unauthorised person is a person who has not been instructed to work on the METAL closely fitting working clothes which cannot get caught in rotating parts ( conveyor belt).7 Software Version and higherChapter 3 Safety MessagesKeep the floor at your place of work clean.
8 Remove oil and obstructions flames and smoking are not control equipment and electronic controllers are connected to hazardous line touch any live parts. Electric shocks may lead to severe injury or power before checking controllers or performing maintenance, be sure equipment is properly connected to Protective Earth (PE).During servicing or maintenance work always wear insulated safety shoes with thick crepe soles and safety any damaged cables to the maintenance staff all access doors to the electrical equipment NOT operate the machine without guards in NOT touch parts marked with this symbol during machine in shark 2 Operator s ManualSoftware Version and Safety Instructions for the METAL DetectorAttention! Smooth and safe running of METAL shark BD METAL Detectors is only possible if the fol-lowing measures have been Installation InstructionsAlways attach an earth clamp for welding equipment directly next to the allow the welding current to flow through the housing of the METAL detector.
9 This would damage the METAL detector beyond Connecting Instructions yMake sure that the mains voltage is the same as that required for the equipment. yThe detector must be fitted and connected up by trained staff only. yObserve general installation regulations for setting up and operating electrical equipment (VDE 0100). yConsequently, never perform any work on the METAL detector when it is switched on. yTake precautions to protect human life and the machine in accordance with the local conditions and regulations. yThe METAL Detector METAL shark 2 BD series is designed for permanent, steady-state installation. yNever connect or disconnect control cables or coaxial cables whilst the METAL detector is switched on. yNever connect mains cables, control cables or coaxial cables incorrectly.
10 YObserve maximum operating voltage and the current-carrying capacity of the output contacts. yUse screened/twisted-wire mains and control cables. yNever lay the mains cable and control cable together in a single cable run. yMake sure the METAL detector is properly earthen (protective earth - PE). Instructions about OperationTo prevent METAL Detector METAL shark series from ageing prematurely or being damaged beyond repair, please observe the following instructions: yThe METAL detector should always remain switched on. This will maximise the service life of the electronic circuitry. yOnly operate the METAL detector under suitable conditions (refer to chapter Normal Use ). Protection against InterferenceThe mains input of the METAL detector is protected against interference.