Metalux22 RDILED2' X 2' troffer LED MODULES pecification grade TrofferPS519177 ENJune 4, 2018 11:25 AMThe Ovation LED Series is a complete family of recessed direct/indirect luminaires dedicated to the latest solid state lighting and drives technology for optimal performance and energy efficiency. All components are located above the ceiling plane for a clean architectural appearance in the finished space. Carefully balanced design elements combine to provide an efficient and exciting alternative to traditional general lighting. Ovation LED is an excellent choice for commercial office spaces, schools, hospitals, or retail merchandising Safe and convenient means of disconnecting power23-11/16"[602mm]3-1/4"[88mm]23-3/4" [603mm]2-1/2"[64mm]1-1/2"[38mm]WiringAcc ess Plate7/8" [22mm] (2) MOUNTING DATAGGrid/Lay-inStandardTSlot GridFDrywall FrameKitCeilingTrimType**TypeExposed GridGConcealed TG or TSlot GridG or TFlange**CEILING COMPATIBILITYCERTIFICATION DATAcULus - 1598 Damp Location ListedIC RatedLM79/LM80 Compliant DesignLights Consortium QualifiedNOM Compliant*See Drywall Frame Kit Accessory in Ordering Information SectionSPECIFICATION FEATURESC onstructionNominal 6" deep housing is die formed of code gauge, prime cold rolled steel.

Metalux 22RDI LED 2' X 2' TROFFER LED MODULE Specification Grade Troffer PS519177EN June 4, 2018 11:25 AM The Ovation LED Series is …

Tags:

  Specification, Grade, Troffer, Ovations, Specification grade troffer, The ovation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Metalux 22RDI Ovation LED 2' x 2' Specification …

1 Metalux22 RDILED2' X 2' troffer LED MODULES pecification grade TrofferPS519177 ENJune 4, 2018 11:25 AMThe Ovation LED Series is a complete family of recessed direct/indirect luminaires dedicated to the latest solid state lighting and drives technology for optimal performance and energy efficiency. All components are located above the ceiling plane for a clean architectural appearance in the finished space. Carefully balanced design elements combine to provide an efficient and exciting alternative to traditional general lighting. Ovation LED is an excellent choice for commercial office spaces, schools, hospitals, or retail merchandising Safe and convenient means of disconnecting power23-11/16"[602mm]3-1/4"[88mm]23-3/4" [603mm]2-1/2"[64mm]1-1/2"[38mm]WiringAcc ess Plate7/8" [22mm] (2) MOUNTING DATAGGrid/Lay-inStandardTSlot GridFDrywall FrameKitCeilingTrimType**TypeExposed GridGConcealed TG or TSlot GridG or TFlange**CEILING COMPATIBILITYCERTIFICATION DATAcULus - 1598 Damp Location ListedIC RatedLM79/LM80 Compliant DesignLights Consortium QualifiedNOM Compliant*See Drywall Frame Kit Accessory in Ordering Information SectionSPECIFICATION FEATURESC onstructionNominal 6" deep housing is die formed of code gauge, prime cold rolled steel.

2 Heavy gauge end plates are securely attached with screws for strength and rigidity and the elimination of gaps. Four auxiliary fixture end suspension points are LED luminaires come standard with 0-10V dimming drivers (1% standard). Options compatible with Eaton s Connected Lighting Systems: LumaWatt Pro sensor Fifth Light DALI driverOther options include step-dimming and 3rd party drivers. Refer to the Connected Lighting options page and ordering information for more LED system coupled with electrical driver to deliver optimal performance. LED s available in 3000K, 3500K, 4000K or 5000K with a minimum CRI of 80. Projected life is 60,000 hours at 80% lumen output. cULus listed. Electronic drivers are available for 120-277V and 347V Battery Pack OptionOptional 120v-277v integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring code-compliance.

3 The patented EZ Key prevents accidental discharge of the battery during construction. Emergency/generator transfer options available see ordering information for cold rolled steel with multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust reflector has high reflectance baked matte white enamel finish for luminous uniformity. Positively retained direct lamp shield is constructed of heavy gauge perforated steel with high reflectance painted after fabrication finish and milky white overlay diffuser for visual comfort. All reflectors are precision formed in a computer-controlled are UL recognized components and indoor luminaires are cULus listed for 25 C ambient environments, and LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium Qualified and classified for DLC Standard, refer to for year "[603 mm]6"[152mm]Catalog #ProjectCommentsPrepared byTypeDateSpecifications and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: LED 2' X 2'PHOTOMETRICS22 RDI-30-UNV-L840-CD1-UElectronic DriverLinear LED 4000 KSpacing criterion: (II) x mounting height, ( ) x mounting heightLumens: Watts: : lm/WTest Report.

4 II45 Across 1049 1049 10491040 1045 10491023 1031 1038994 1007 1020957 976 997907 936 967850 890 930785 836 889714 776 836636 713 781556 643 716466 570 633373 485 541281 393 439198 301 346128 209 26471 131 16826 52 680 0 0 Coefficients of UtilizationEffective floor cavity reflectance 20%rc80%70%50%30%10%0%rw7050301070503010 503010503010503010 0 RCR012345678910119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100109 104 99 96 106 102 98 94 97 94 91 93 91 88 90 88 86 8399 90 83 78 96 88 82 77 85 79 75 82 77 73 78 75 71 6990 79 71 64 87 78 70 64 75 68 63 72 66 61 69 64 60 5882 70 61 54 80 69 60 54 66 59 53 64 58 52 62 56 52 5076 62 53 47 73 61 53 46 59 52 46 57 51 45 55 50 45 4370 56 47 41 68 55 47 41 53 46 40 52 45 40 50 44 39 3765 51 42 36 63 50 42 36 49 41 35 47 40 35 46 40 35 3360 46 38 32 59 46 38 32 44 37 32 43 36 31 42 36 31 2956 43 34 29 55 42 34 29 41 34 28 40 33 28 39 33 28 2653 39 31 26 51 39 31 26 38 31 26 37 30 26 36 30 26 24 Zonal

5 Lumen SummaryZoneLumens% Fixture0-300-400-600-900-180815 DataAnglein DegAverage0-Degcd/smAverage45-Degcd/smAv erage90-Degcd/sm45556575852420 2713 29722186 2674 29701789 2502 27951331 2173 2745803 1606 21002630 30 40 50 70 90 20 80 60 526788105110 22 RDI-40-UNV-L835-CD1-UElectronic DriverLinear LED 3500 KSpacing criterion: (II) x mounting height, ( ) x mounting heightLumens: Watts: : lm/WTest Report: 22 RDI-40-UNV- II45 Across 1406 1406 14061395 1401 14061371 1381 13911332 1350 13681282 1308 13371215 1256 12961142 1194 12511053 1120 1191957 1040 1123851 955 1050748 862 957627 765 845505 653 726380 528 591265 406 469174 280 35696 175 22435 71 900 0 0 Coefficients of UtilizationEffective floor cavity reflectance 20%rc80%70%50%30%10%0%rw7050301070503010 503010503010503010 0 RCR012345678910119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100109 104 99 96 106 101 98 94 97 94 91 93 91 88 90 88 86

6 8399 90 83 78 96 88 82 77 85 79 75 82 77 73 78 75 71 6990 79 71 64 87 78 70 64 75 68 63 72 66 61 69 64 60 5882 70 61 54 80 69 60 54 66 59 53 64 58 52 62 56 52 5075 62 53 47 73 61 53 46 59 52 46 57 51 45 55 50 45 4370 56 47 41 68 55 47 40 53 46 40 52 45 40 50 44 39 3765 51 42 36 63 50 42 36 49 41 35 47 40 35 46 40 35 3360 46 38 32 58 46 38 32 44 37 32 43 36 31 42 36 31 2956 43 34 29 55 42 34 29 41 34 28 40 33 28 39 33 28 2653 39 31 26 51 39 31 26 38 31 26 37 30 26 36 30 26 24 Zonal Lumen SummaryZoneLumens% Fixture0-300-400-600-900-1801093 DataAnglein DegAverage0-Degcd/smAverage45-Degcd/smAv erage90-Degcd/sm45556575853239 3634 39962942 3589 39642420 3362 37631809 2911 37011081 2192 27793520 30 40 50 70 90 20 80 60 7051057140910 Ambient TemperatureTM-21 LumenMaintenance(60,000 hours)TheoreticalL70 (Hours)25 C> 90%> 60,000 LUMEN MAINTENANCEENERGY AND PERFORMANCE DATA BY CATALOG NUMBERS tock orMTO*Catalog Logic(Curved)DeliveredLumensWattsEfficac y(LPW) *Made to order (MTO) requires a typical three week lead 4, 2018 11:25 AMSpecifications and dimensions subject to change without 1121 Highway 74 SouthPeachtree City, GA 30269P: LED 2' X 2'Catalog No.

7 19 DATAORDERING INFORMATIONACCESSORIESEQ-CLIP-U=T-BAR Safety Earthquake Clips (1)DF-22-W=2' x 2' Drywall Frame KitSK-22-WT=2' x 2' Tall Surface Mount KitDF10P-C =Decorator Dimmer, 0-10 VSF10P- =Decorator Slide Dimmer, 0-10 VSAMPLE NUMBER: 2 2 RDI-30-UNV-L840-CD1-UShieldingBlank=Meta l Perforated Lens (standard)Voltage(2)347V=347 Volt (4) UNV=UniversalVoltage 120-277 Number of Drivers1=1 DriverPackagingU=Unit PackPALC=JobPack, in cartonNOTES: (1)An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (2)Products also available in non-US voltages and frequencies for international markets. (3)With integral test switch/indica-tor. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (4)347V versions are not available with emergency options.

8 SD, 5 LTD, not available. (5)Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). GTR2 and ETR2 options include 2 relays on fixtures with dimming drivers. ETRD option only requires one relay when used on a dimming fixture. Must specify voltage as 120V or 277V when ordering these devices. (6)Air version is vented but does not meet air handling requirements; a 3% reduction in delivered lumens is experienced with this option. (7)Chicago rated and air vented cannot be ordered in combination with each other. (8)DesignLights Consortium Qualified and classified for DLC Standard, refer to for , 120V-277V emergency battery pack installed (3)EL14W=14-watt 120V-277V emergency battery pack installed (3)GTR2=Bodine Generator Transfer Relay (5) ETR2=Iota Emergency Transfer Relay (5)ETRD=Iota Emergency Transfer Relay with dimming control (5)CCTL830=3000KL835=3500KL840=4000 KFlexA3/8-4/18 GDIM=3/8" Flex with 0-10V Dimming LeadsMultiple other configurations available.

9 See below for TypeCD=0-10V Dimming Driver (1%-100% Dimming)SD=Step Dimming Driver (50% or 100% Dimming)5 LTD=Fifth Light DALI Driver (10%-100% Dimming) (7)Series (8)22 RDI=2x2 Ovation Series(Recessed Direct/Indirect)Lumen Output20=2000 Lumens30=3000 Lumens40=4000 LumensOvationAir[Blank]=StandardA=Air (Vented) (6), (7) RatingBlank=StandardATW-SW4=ChicagoRated (7) Integrated Sensing SystemsLWTPD1=LumaWatt Pro Wireless Tile-mount Sensor (A)Integrated Sensing and Control System OptionsNOTES: Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A)Consult LumaWatt Pro system pages for additional details and compatibility. (B)Consult Fifth Light system pages for additional details and Metal Conduit OptionsFlex options available for 0-10V dimming control, DALI dimming control, emergency and night light functions.

10 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 90 enclosed FMC connector. Not all options may be combined and installation ratings vary by series notes: Factory installed dimming option 3/8 flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed 0-10V +/- control wires. Meets UL 66, 83, 1479, 1569, 1581, 2556. NEC , (C), 392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645, 72; Federal Specification A-A-59544 (formerly J-C-30B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC ; Environmental Air-Handling Space Installation per NEC (C ).Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering 4, 2018 11:25 AM