Example: bachelor of science

Micro Motion F-Series Flow and Density Meters

product data SheetPS-00603, Rev AGJuly 2020 Micro Motion F-Series Flow and DensityMetersHigh accuracy real world performance Best-in-class performance on liquid mass flow, volume flow, and densitymeasurements in a compact design (up to liquid mass accuracy and up to kg/m3 liquid Density accuracy) Rugged design minimizing process, mounting, and environmental effects VIEW product >Best fit-for-application Cleanable, self-draining design for critical process control service Compact design enables installation flexibility Broad range of I/O offerings including HART , Profibus-DP, FOUNDATION fieldbus, 4-20 mA, and wirelesscapabilitiesExceptional reliability and safety No moving parts to wear or replace minimizes maintenance for long-term reliability 316L stainless steel and nickel alloy C22 wetted parts construction for compatibility with most fluids Robust sensor designMicro Motion F-Series flow and Density metersMicro Motion F-Series Meters deliver superb measurement with exceptional flow and Density performance as well as outstandingreli

Product Data Sheet PS-00603, Rev AB January 2019 Micro Motion® F-Series Flow and Density Meters High accuracy real world performance Best-in-class performance on liquid mass flow, volume flow, and density measurements in a compact

Tags:

  Product, Series, Sheet, Data, Flows, Meters, Product data sheet, Density, Density meter, Series flow

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Micro Motion F-Series Flow and Density Meters

1 product data SheetPS-00603, Rev AGJuly 2020 Micro Motion F-Series Flow and DensityMetersHigh accuracy real world performance Best-in-class performance on liquid mass flow, volume flow, and densitymeasurements in a compact design (up to liquid mass accuracy and up to kg/m3 liquid Density accuracy) Rugged design minimizing process, mounting, and environmental effects VIEW product >Best fit-for-application Cleanable, self-draining design for critical process control service Compact design enables installation flexibility Broad range of I/O offerings including HART , Profibus-DP, FOUNDATION fieldbus, 4-20 mA, and wirelesscapabilitiesExceptional reliability and safety No moving parts to wear or replace minimizes maintenance for long-term reliability 316L stainless steel and nickel alloy C22 wetted parts construction for compatibility with most fluids Robust sensor designMicro Motion F-Series flow and Density metersMicro Motion F-Series Meters deliver superb measurement with exceptional flow and Density performance as well as outstandingreliability for use in critical process control flow and Density fit for critical process applications High performance rugged measurement in a compact drainable design that maximizes process up time Low frequency.

2 High sensitivity fit-and-forget meter provides robust measurements even under demanding process conditions Multiple line sizes provide an ideal platform for batching, distribution, allocation and intra-plant measurement applicationsSmart Meter Verification : advanced diagnostics for your entire system Included as standard, with the option to license flow range detection and other advanced meter health diagnostics A comprehensive test that can be scheduled, run locally, or from the control room to provide confidence in your meterfunctionality and performance Verifies that your meter performs as well as the day it was installed, giving you assurance in less than 90 seconds Saves significant expenditure by reducing labor and extending or eliminating calibration intervals without interrupting theprocessIndustry-leading capabilities that unleash your process potential Available with the most extensive offering of transmitter and mounting options for maximum compatibility with your system State of the art.

3 ISO/IEC 17025 compliant calibration stands achieving uncertainty drive best in class measurementaccuracy The most comprehensive communication protocol offering in the industry including Smart Wireless True multi-variable technology measures necessary flow and Density process variables simultaneouslyWidest range of installation and process condition flexibility Featuring a low pressure drop, low weight design that reduces installation and commissioning costs Unmatched MVD transmitter technology with digital signal processing (DSP) delivers the fastest response rates enablingaccurate batch and process measurement Design flexibility enables operation at high temperature up to 662 F (350 C) or high pressure up to 6,237 psig (430 barg) tosolve your toughest measurement challengesAccess information when you need it with asset tagsNewly shipped devices include a unique QR code asset tag that enables you to access serialized information directly from thedevice.

4 With this capability, you can: Access device drawings, diagrams, technical documentation, and troubleshooting information in your MyEmerson account Improve mean time to repair and maintain efficiency Ensure confidence that you have located the correct device Eliminate the time-consuming process of locating and transcribing nameplates to view asset informationF- series Flow and Density MetersJuly principlesAs a practical application of the Coriolis effect, the Coriolis mass flow meter operating principle involves inducing a vibration of theflow tube through which the fluid passes. The vibration, though it is not completely circular, provides the rotating reference framewhich gives rise to the Coriolis effect.

5 While specific methods vary according to the design of the flow meter, sensors monitor andanalyze changes in frequency, phase shift, and amplitude of the vibrating flow tubes. The changes observed represent the massflow rate and Density of the and volume flow measurementThe measuring tubes are forced to oscillate producing a sine wave. At zero flow, the two tubes vibrate in phase with each flow is introduced, the Coriolis forces cause the tubes to twist resulting in a phase shift. The time difference between thewaves is measured and is directly proportional to the mass flow rate. Volume flow rate is calculated from mass flow rate and thedensity this video to learn more about how a Coriolis flow meter measures mass flow and Density (click the link and select ViewVideos): Inlet pickoff displacementB.

6 No flowC. Outlet pickoff displacementD. TimeE. Inlet pickoff displacementF. With flowG. Outlet pickoff displacementH. Time differenceI. TimeDensity measurementThe measuring tubes are vibrated at their natural frequency. A change in the mass of the fluid contained inside the tubes causes acorresponding change to the tube natural frequency. The frequency change of the tube is used to calculate 2020F- series Flow and Density measurementTemperature is a measured variable that is available as an output. The temperature is also used internal to the sensor tocompensate for temperature influences on Young s Modulus of characteristics Measurement accuracy is a function of fluid mass flow rate independent of operating temperature, pressure, or , pressure drop through the sensor is dependent upon operating temperature, pressure, and fluid composition.

7 Specifications and capabilities vary by model and certain models may have fewer available options. For detailed informationregarding performance and capabilities, either contact customer service or visit The letter at the end of the base model code (for example F100S) represents wetted part material and/or applicationdesignation: S = stainless steel, H = nickel alloy C22, P = high pressure, A = high temperature 316L stainless steel, B = hightemperature nickel alloy C22. Detailed information about the complete product model codes are described later in specificationsReference operating conditionsMicro Motion calibrates: Water at 68 F ( C) to 77 F ( C) and psig (1 barg) to 29 psig (2 barg) Accuracy based on industry leading accredited calibration standards according to ISO/IEC 17025 A Density range up to 3 g/cm (3,000 kg/m )Accuracy and repeatabilityAccuracy and repeatability on liquids and slurriesPerformance specificationsPremium(1)Enhanced(1)Inter mediateBasicMass and volume flow(2) and volume repeatability accuracy g/cm ( kg/m ) g/cm ( 1 kg/m ) g/cm ( 2 kg/m ) Density repeatability g/cm ( kg/m ) g/cm ( kg/m ) g/cm ( 1 kg/m )Temperature accuracy 1 C of readingTemperature repeatability C(1)Not available on all models.

8 (2)Stated flow accuracy includes the combined effects of repeatability, linearity, and Flow and Density MetersJuly and repeatability on gasesPerformance specificationF050S/H, F100S/H, F200S/H, F300S/H,and F400SF025S/H, all high temperature (A/B),and high pressure (P) modelsMass flow accuracy(1) of rate of rateMass flow repeatability(1) of rate of rateTemperature accuracy 1 C of readingTemperature repeatability C(1)Stated flow accuracy includes the combined effects of repeatability, linearity, and options on all F-Series modelsThe warranty period is generally initiated from the day of shipment. For warranty details, see the Terms and Conditions included withthe standard product modelIncluded as standardIncluded with startup serviceAvailable for purchaseF025-400 (S/H/A/B/P)18 months36 months> 36 months (customizablelength)Liquid flow ratesNominal flow rateMicro Motion has adopted the term nominal flow rate, which is the flow rate at which water at reference conditions causesapproximately psig (1 barg) of pressure drop across the flow rates for all modelsThe following table shows mass flow rates using 316L stainless steel (S/A), nickel alloy C22 (H/B), and high pressure (P).

9 ModelNominal line sizeNominal flow rateMaximum flow ratelb/minkg/hlb/ in (DN6)501,3661002, in (DN15)842,2871684,570F050S/H/ in (DN15)1554,2263008,160F100P1 in (DN25)40011,00080022,000F100S/H/A/B1 in (DN25)71719,5001,20032,700F2002 in (DN50)2,19059,5003,20087,100F3003 in (DN80)4,900133,0008,740238,000F4004 in (DN100)12,000327,00016,000436,000 July 2020F- series Flow and Density flow rates for all modelsThe following table shows volume flow rates using 316L stainless steel (S/A), nickel alloy C22 (H/B), and high pressure (P).ModelNominal flow rateMaximum flow rategal/minbarrels/hl/hgal/minbarrels/hl /hF025691,37012182,720F050S/H/A/B19274,2 3038528,160F050P10152,29020294,570F100P4 86911,0009613822,000F100S/H/A/B8612319,5 0014420632,700F20026237459,50038455087,1 00F300587839133,0001,0501,500238,000F400 1,4402,050326,0001,9202,730435,000 Gas flow ratesGas flow ratesWhen selecting sensors for gas applications, pressure drop through the sensor is dependent upon operating temperature,pressure, and fluid composition.

10 Therefore, when selecting a sensor for any particular gas application, it is highly recommendedthat each sensor be sized using the Online Store Sizing and Selection Tool at flow rates for all modelsFor general recommendations on nominal and maximum gas mass flow rates a Mach number of or , respectively, use the gasbeing measured. The Sizing and Selection Tool will report both the actual velocity and the sonic velocity for each flow rate andmeter size considered. The ratio of actual velocity divided by sonic velocity reflects the Mach number, or alternatively, the massflow rate to match a particular Mach number can be calculated with the following formula: (gas) = %M * (gas) * VOS * 14 *D2 * 2 (for sensors with dual tube design) (gas)Gas mass flow rate%MUse Mach number for calculating typical nominal rate; use Mach number for calculating maximumrecommended rate.