Example: tourism industry

Micro Motion Model 2700 Transmitters with …

Configuration and Use Manual20000327, Rev FCJuly 2016 Micro Motion Model 2700 Transmitters with profibus -PASafety and approval informationThis Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the internet at or through your local Micro Motion support affixed to equipment that complies with the Pressure Equipment Directive can be found on the internet at hazardous installations in Europe, refer to standard EN 60079-14 if national standards do not informationFull product specifications can be found in the product data sheet. Troubleshooting information can be found in the transmitter configuration manual.

8 Model 2700 Transmitters with PROFIBUS-PA 1.4 PROFIBUS-PA functionality The transmitter supports the following methods of configuration and operation: • …

Tags:

  With, Model, 2007, Transmitter, Profibus, Model 2700 transmitters with, Model 2700 transmitters with profibus pa

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Micro Motion Model 2700 Transmitters with …

1 Configuration and Use Manual20000327, Rev FCJuly 2016 Micro Motion Model 2700 Transmitters with profibus -PASafety and approval informationThis Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the internet at or through your local Micro Motion support affixed to equipment that complies with the Pressure Equipment Directive can be found on the internet at hazardous installations in Europe, refer to standard EN 60079-14 if national standards do not informationFull product specifications can be found in the product data sheet. Troubleshooting information can be found in the transmitter configuration manual.

2 Product data sheets and manuals are available from the Micro Motion web site at policyMicro Motion procedures must be followed when returning equipment. These procedures ensure legal compliance with government transportation agencies and help provide a safe working environment for Micro Motion employees. Failure to follow Micro Motion procedures will result in your equipment being refused on return procedures and forms is available on our web support system at , or by phoning the Micro Motion Customer Service Motion customer serviceEmail: Worldwide: Asia-Pacific: and South AmericaEurope and Middle EastAsia PacificUnited 240 1978 Australia800 158 727 Canada+1 303-527-5200 The Netherlands+31 (0) 704 136 666 New Zealand099 128 804 Mexico+41 (0) 41 7686 111 France0800917901 India800 440 1468 Argentina+54 11 4837 7000 Germany0800 182 5347 Pakistan888 550 2682 Brazil+55 15 3413 8000 Italy8008 77334 China+86 21 2892 9000 Venezuela+58 26 1731 3446 Central & Eastern+41 (0) 41 7686 111 Japan+81 3 5769 6803 Russia/CIS+7 495 981 9811 South Korea+82 2 3438 4600 Egypt0800 000 0015 Singapore+65 6 777 8211 Oman800 70101 Thailand001 800 441 6426 Qatar431 0044 Malaysia800 814 008 Kuwait663 299 01 South Africa800 991 390 Saudia Arabia800 844 9564 UAE800 0444 0684 ContentsChapter 1 Before You Begin.

3 transmitter functionality .. version information .. the configuration .. worksheet .. 2 Startup .. power .. the node the analog input function block channels .. the I/O the totalizer block mode .. pressure temperature compensation .. 23 Chapter 3 Calibration .. , Smart Meter Verification, meter validation, and calibration .. a characterization .. Smart Meter meter validation .. zero calibration .. density calibration ..48 Chapter 4 Configuration .. target map .. standard volume flow measurement for gas .. the measurement units .. the petroleum measurement the concentration measurement application .. the output scale .. process status alarm severity .. the damping values .. slug flow limits and cutoffs .. the measurement mode parameter.

4 Sensor parameters .. the display .. LD Optimization .. 904 Model 2400S TransmittersChapter 5 Operation .. the I&M functions .. process variables .. process variables .. sensor simulation mode .. diagnostic information with a profibus host .. transmitter status and alarms .. the totalizers and inventories .. 98 Chapter 6 Troubleshooting .. to troubleshooting topics .. does not operate .. does not communicate .. blocks in Out-of-Service or calibration failure .. problems .. alarms .. wiring problems .. slug flow .. a working configuration .. the test points .. the core processor .. sensor coils and RTD ..120 Flowmeter Installation Types and Components diagrams .. and terminal diagrams ..127 Using the Display .. the optical switches .. the display.

5 Menus .. 140 Connecting with ProLink III to a personal computer .. 149 profibus -PA Status Byte status byte format .. status byte 152 Slave Diagnostic Response Bytes specification diagnostic bytes .. 155 Configuration and Use Manual5 Model 2700 profibus Block Parameters .. identification .. block .. block 1 (measurement, calibration, and diagnosis) .. 168NE53 History .. change history .. 2076 Model 2400S TransmittersConfiguration and Use Manual71 Before You chapter provides an orientation to the use of this manual, and includes a configuration overview flowchart and a pre-configuration worksheet. This manual describes the procedures required to start, configure, use, maintain, and troubleshoot Micro Motion Model 2700 Transmitters with messages are provided throughout this manual to protect personnel and equipment.

6 Read each safety message carefully before proceeding to the next transmitter informationTransmitter options are indicated by the Model number located on the transmitter tag. The Model number is a string of the following form: 2700 * 1 * G * * * * * *Mounting code:R = 4-wire remote mountI = Integral mountB = 4-wire remote mount to 9-wire remote core processorC = 9-wire remote mountDisplay code1 = Display with glass lens2 = Backlit display with glass lens3 = No display5 = Backlit display with IIC approval, glass lens7 = Backlit display with non-glass lensOutput option codeG = profibus -PASoftware code 1:G = Concentration measurement applicationA = Petroleum measurement (API) applicationSoftware code 2:C = Smart Meter Verification8 Model 2700 Transmitters with functionalityThe transmitter supports the following methods of configuration and operation: Configuration methods:-Device description (EDD) for use with a profibus configuration tool such as Siemens Simatic Process Device Manager (PDM).

7 In this manual, the term EDD is used to refer to this type of read and write of profibus -PA bus parameters. Operation methods:-GSD file with a profibus host. The transmitter supports two GSD options Profile-specific, which is created by PNO, and Manufacturer-specific, which is created by by Micro Motion in order to implement a larger set of function blocks. See Section for more information about the two GSD this manual, the term host or profibus host is used to refer to this type of description (EDD) with profibus configuration tool ( , Simatic PDM). The EDD provides a superset of the operational functionality of the GSD, plus configuration capability. Identification and maintenance (I&M) functions:-I&M 0-I&M 1-I&M 2-PA I&M 0 The transmitter supports both classic and condensed status byte formats. Classic mode conforms to the profibus -PA Profile , Section Condensed mode conforms to the profibus -PA Specification June 2005 Amendment 2 to the profibus Profile , Condensed Status and Diagnostic Messages version informationTable 1-1 lists the version information you may need to know and describes how to obtain the information.

8 Make sure you have the latest versions of the transmitter and ProLink :The hardware for Transmitters with and lower firmware is incompatible with the hardware needed to support and later firmware. To upgrade from an earlier firmware version to or higher firmware requires hardware and Use toolsMost of the procedures described in this manual require the use of a communication tool. Table 1-2 lists the communication tools that can be used, with their functionality and PDM and GSD files can be downloaded from the following address: available at this address is a document titled Commissioning MVD profibus PA Documentation Supplement. This supplement will assist you with connecting to the transmitter with Siemens Simatic Process Device Manager (PDM). If you are using Simatic PDM, download the PDM file set and follow the EDD instructions in this information on using the display is provided in Appendix 1-1 Obtaining version informationComponentToolMethodTransmitte r softwareWith ProLink IIIView > Installed Options > Software RevisionWith EDDMMI Coriolis Flow > Transducer Block > Device Information > Software RevWith displayOFF-LINE MAINT > VERCore processor softwareWith ProLink IIINot availableWith EDDNot availableWith displayOFF-LINE MAINT > VERProLink IIIWith ProLink IIIHelp > About ProLink IIIGSD version(1)(1)There are two GSD options available: Manufacturer-specific and Profile-specific.

9 See Section for more editorOpen file or and check parameter GSD_RevisionEDD versionText editorOpen file and check parameter DD_REVISIONNote:You can use ProLink III, the EDD, or profibus bus parameters for transmitter setup and maintenance. It is not necessary to have more than one of these methods 1-2 Communication tools for Model 2700 transmitter with profibus -PAToolFunctionalityRequirements View/operationSetup/maintenanceTransmitt er displayPartialPartialTransmitter with displayProLink IIIFullFullProLink III or laterHost(1)(1)There are two GSD options available: Manufacturer-specific and Profile-specific. See Section for more file or file setBus parametersFullFullNone10 Model 2700 Transmitters with profibus -PABasic information on ProLink III is provided in Appendix C. For more information, refer to the ProLink III manual, which is available on the Micro Motion web site ( ).

10 For full configuration, maintenance, and operation of the Model 2700 transmitter with profibus -PA, use the latest version of ProLink the configurationRefer to the configuration overview flowchart in Figure 1-1 to plan transmitter configuration. In general, perform configuration steps in the order shown :Depending on your installation and application, some configuration tasks may be manual provides information on topics that are not included in the configuration overview flowchart, , using the transmitter , troubleshooting, and calibration procedures. Be sure to review these topics as and Use Manual11 Figure 1-1 Configuration overview Chapter 2 Flowmeter StartupChapter 1 Before You BeginFill out pre-configuration worksheetApply powerSet node addressChapter 3 CalibrationOPTIONALC haracterize the flowmeterZero the flowmeterVerify meter performanceValidate against a standardCalibrate for densityCalibrate for temperatureChapter 4 ConfigurationConfigure AI function block channelsSet I/O modeMeasurement unitsOutput scaleProcess alarmsDampingSlug flowAlarm severityGas standard volumePetroleum measurementConcentration measurementCutoffsMeasurement modeDevice settingsSensor parametersDisplay functionalityOptional:Configure pressure compensationOptional.


Related search queries