Example: biology

Micro Trims April 2019 Fisher Micro Trims for Globe and ...

Product Bulletin Micro Trims :010. D102702X012 September 2017. Fisher Micro Trims for Globe and Angle Valve Applications W5816-1. Micro Flute W5817-1. W8282 W8284. Micro Form Micro Flow Micro Flat/Form W8285. MULTI STAGE Micro Flat W5624LG. CAV III Micro Flat W6021. X0469-1. Micro Flat CAVITATION CAV4 Mini Micro Trims Product Bulletin :010 Micro Trims September 2017 D102702X012. Fisher Micro Trims are used in those applications where Severe Service Micro Trims the control of low flow rates is a requirement. A variety of Micro Trims are offered that provide application solutions for standard and severe service conditions. Cavitation Isolation Trim Controls where cavitation This bulletin lists the various Micro Trims available and occurs in the valve to minimize trim damage.

ES EAS HPAS DA 1, 1-1/2, and 2 1 and 2 1 and 2 1 0.001 ‐ 3.4 0.001 - 10.49 0.01 ‐ 7.8 ... size EH and HP control valves. Figure 4. Micro‐Flat/Form Trim FLOW W8284 ... and 2 Fisher ES valve bodies and is designed for very low flow applications where cavitation is a concern.

Tags:

  Control, Valves, Fisher, Control valves, Es eas, Fisher es

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Micro Trims April 2019 Fisher Micro Trims for Globe and ...

1 Product Bulletin Micro Trims :010. D102702X012 September 2017. Fisher Micro Trims for Globe and Angle Valve Applications W5816-1. Micro Flute W5817-1. W8282 W8284. Micro Form Micro Flow Micro Flat/Form W8285. MULTI STAGE Micro Flat W5624LG. CAV III Micro Flat W6021. X0469-1. Micro Flat CAVITATION CAV4 Mini Micro Trims Product Bulletin :010 Micro Trims September 2017 D102702X012. Fisher Micro Trims are used in those applications where Severe Service Micro Trims the control of low flow rates is a requirement. A variety of Micro Trims are offered that provide application solutions for standard and severe service conditions. Cavitation Isolation Trim Controls where cavitation This bulletin lists the various Micro Trims available and occurs in the valve to minimize trim damage.

2 Does not their service capability. prevent formation of cavitation. Cavitation Elimination Trim Trim design eliminates the effects of cavitation. Trim Descriptions: An Overview (E) Micro Flat Cavitation Trim Cavitation isolation trim. Very low flow control . Isolates cavitation to Fisher Micro Trims fall into two basic application minimize trim degradation. Plug-characterized, categories: Standard Service and Severe Service . port-guided, unbalanced trim. See figure 5. Standard Service Micro Trims (F) Multi Stage Micro Flat Plug/Cage design with a These are Plug Characterized Trims . Flow series of flats on a common stem. High nP's and Cv's characterization is controlled by the plug.

3 Down to approximately This is a cavitation elimination trim for use on liquids. Not intended for (A) Micro Flow Ultra low flow control . Linear flow gas service. See figure 6. characteristic. Plug characterized, port guided. Gas and liquid applications. See figure 1. (G) CAV III Micro Flat Cage guided cavitation (B) Micro Flute Low flow control . Bridges the gap elimination trim. This trim is a CAV III multi stage trim between Micro Flow and Micro Form Trims . Equal with the addition of a Micro Flat style plug to provide percent flow characteristic. Plug characterized, staged performance at low flows. Allows CAV III staged port guided. Gas and liquid applications. See figure 2.

4 Cavitation control as low as Cv = See figure 7. (C) Micro Form Equal percent, contoured plug used in a variety of valve designs. See figure 3. (H) CAV4 Mini Plug/Cage design with a series of (D) Micro Flat/Form General service gas or liquid staged pressure drops. This multi-stage cavitation applications where high rangeability (>200:1) is elimination valve trim is used in high pressure drops required. See figure 4. and low flows. See figure 8. 2. Product Bulletin Micro Trims :010. D102702X012 September 2017. Table 1. Micro Trim Application(1). Trim Trim Name Valve Type Valve Size Range, NPS Cv Availability(2, 3). EZ 1/2, 3/4, 1, 1 1/2, and 2 - (A) Micro Flow HP 1 D 1 EZ 1/2, 3/4, 1, 1 1/2, and 2 (B) Micro Flute HPS 1 D 1 easy et 1, 1 1/2, and 2 HPS 1 and 2 (C) Micro Form EH 2 D 1 and 2 easy e 1, 1 1/2, and 2 HPS 1 and 2 (D) Micro Flat/Form EH 2 D 1 and 2 ES 1, 1-1/2, and 2 EAS 1 and 2 - (E) Micro Flat Cavitation HPAS 1 and 2 DA 1 ES 1, 1 1/2, and 2 (F) Multi Stage Micro Flat HPS 1 and 2 EHS 2 ES 1, 1 1/2, and 2 (G) CAV III Micro Flat HPS 1 and 2 EHS 2 (H) CAV4 4-Stage Mini EH 2 1.

5 Configurations shown are standard. Other configurations are available. Consult your Emerson sales office or Local Business Partner. 2. The trim selected may have the minimum or the maximum Cv, as shown below, but usually not both. Refer to Catalog 12 for further detail on flow coefficients for the various valve types. 3. Consult your Emerson sales office for Cv requirements and availability, dependent on valve size, design, etc. 3. Product Bulletin :010 Micro Trims September 2017 D102702X012. Detailed Trim Description Standard Service Trims Figure 1. Micro Flow Trim Figure 2. Micro Flute Trim W5816-1. W8282. FLOW FLOW. (A) Micro Flow Trim Micro Flow trim (figure 1) provides linear ultra low flow control in gas and liquid applications.

6 Typical (B) Micro Flute Trim application for this trim is flow up, inch port diameter, and inch travel. Micro Flute trim (figure 2) is for low flow equal percent control applications and fills the niche between This is a very rugged, tough trim and therefore Micro Flow applications and Micro Form applications. available in limited materials, such as R30006/CoCr A. Standard trim material is R30006/CoCr A and S44004. Micro Flow trim construction consists of a very tightly controlled angle milled on a flat. This low angle flat provides the required flow control . Micro Flute trim is port guided. The plug tip rides in the seat ring, which is the area where energy is This unbalanced trim, with a linear plug characteristic, dissipated.

7 Typical applications are port diameters as is available in most valve styles, including easy e, D, small as inch and flow up (with some flow down and HP. applications). 4. Product Bulletin Micro Trims :010. D102702X012 September 2017. Figure 3. Micro Form Valve Plug Figure 4. Micro Flat/Form Trim W5817-1 W8284. FLOW FLOW. (D) Micro Flat/Form Trim (C) Micro Form Trim Micro Flat/Form trim (figure 4) is a special plug design for flow up service only. Using features from both Micro Form trim (figure 3) is a contoured plug, equal Micro Flat and Micro Flow Trims , this trim is designed percent trim for low flow applications. This plug for high rangeability flow service. characterized trim is available in inch and larger ports.

8 Micro Form trim is used in flow up applications Micro Flat/Form trim initially operates as Micro Flat, and not recommended for flow down use. where it is tightly tolerenced to optimize low flow control . Further up in the stroke, the trim transitions to a Micro Form style plug contour. This provides Depending on valve type, this trim is either improved Cv coefficient control . Rangeability is cage guided, stem guided, or post guided. possible in excess of 200 to 1. This trim is available in Micro Form trim is widely used in EZ, as well as small Micro Form materials. When choosing materials, be size EH and HP control valves . aware of the sliding contact at low lifts. 5. Product Bulletin :010 Micro Trims September 2017 D102702X012.

9 Severe Service Trims Figure 5. Micro Flat Cavitation Trim FLOW. FLASH BASKET. W6021 X0585-1. FLOW. EAS ES. (E) Micro Flat Cavitation Trim Recommended maximum pressure drop is 1000 psi. Above this, shortened trim life will result. Micro Flat Cavitation trim (figure 5) is available in both NPS 1 and 2 Fisher EAS valve bodies and NPS 1, 1-1/2, and 2 Fisher ES valve bodies and is designed for very This plug characterized, port guided trim is available low flow applications where cavitation is a concern. in hardened materials only, such as R30006/CoCr A. This trim design does not eliminate cavitation, but and S44004. These materials are needed to provide isolates the cavitation to minimize trim degradation.

10 Wear resistance between the plug and seat ring, where Micro -flat Cavitation trim is only available for flow cavitation and vibration problems exist. down applications. Micro Flat Cavitation trim is recommended for angle Micro Flat Cavitation trim features a protected seat valve applications. In special cases, use with a Globe design to maximize seat life in cavitating valve and flash basket is possible. Consult your environments. This trim is available in inch and Emerson sales office or Local Business Partner for larger port diameters with a minimum Cv of additional information. Table 2. Trim Materials(1). TRIM VALVE BODY VALVE BODY SEAT RING / TEMPERATURE LIMITS. VALVE PLUG CAGE.