Example: quiz answers

MicroLogix™ 1500 Controller to MicroLogix 1400 or ...

Migration Solutions MicroLogix 1500 Controller to MicroLogix 1400 Controller or CompactLogix Controller Why Upgrade or Migrate While MicroLogix 1500 Controller has been a valuable part of our portfolio for the past 16 years, this product will no longer be available for sale after June 2017. Now is time to migrate to newer controllers. We recommend migration to either MicroLogix 1400 MicroLogix 1500 Controller or CompactLogix Controller . MicroLogix 1400 is the newest Controller in the MicroLogix Controller family. It uses the same RSLogix . 500 programming software as the MicroLogix 1500. If the MicroLogix 1500 does not use any 1769 Expansion OR. I/O, or uses 1769 I/O modules that have an equivalent 1762 I/O module replacement, we recommend migration MicroLogix 1400 Controller to MicroLogix 1400 Controller . CompactLogix Controller Migrate MicroLogix 1500 to CompactLogix 5370 L1 and L2.

In today’s economy, it is necessary to have migration solutions that help you to achieve increased productivity and lessen your risk of maintaining your legacy equipment. You need to work with a supplier that has the product, service, and industry knowledge to …

Tags:

  Economy, Micrologix

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MicroLogix™ 1500 Controller to MicroLogix 1400 or ...

1 Migration Solutions MicroLogix 1500 Controller to MicroLogix 1400 Controller or CompactLogix Controller Why Upgrade or Migrate While MicroLogix 1500 Controller has been a valuable part of our portfolio for the past 16 years, this product will no longer be available for sale after June 2017. Now is time to migrate to newer controllers. We recommend migration to either MicroLogix 1400 MicroLogix 1500 Controller or CompactLogix Controller . MicroLogix 1400 is the newest Controller in the MicroLogix Controller family. It uses the same RSLogix . 500 programming software as the MicroLogix 1500. If the MicroLogix 1500 does not use any 1769 Expansion OR. I/O, or uses 1769 I/O modules that have an equivalent 1762 I/O module replacement, we recommend migration MicroLogix 1400 Controller to MicroLogix 1400 Controller . CompactLogix Controller Migrate MicroLogix 1500 to CompactLogix 5370 L1 and L2.

2 Controllers if customer prefers to retain 1769 Expansion I/O. ACTIVE* ACTIVE MATURE* END OF LIFE* DISCONTINUED*. CompactLogix Controllers Features and Benefits Identify, Mitigate and Eliminate the Risks Increased flexibility with new of Automation Obsolescence open architecture In today's economy , it is necessary to have migration solutions that help Reduced development time and you to achieve increased productivity and lessen your risk of maintaining costs through reuse of engineering your legacy equipment. You need to work with a supplier that has the practices product, service, and industry knowledge to partner with you on an Maximized returns on existing upgrade strategy that will help you maximize your competitive advantage. assets through improved control Rockwell Automation and its partners will work with you to outline a plan and monitoring that fits your application needs and long-term goals.

3 We can help you Increased access to plant and migrate all at once or in phases, at the pace that is comfortable for you and production information fits your budget. One programming environment With your goals in mind, Rockwell Automation has developed a migration for discrete, motion, process, drive, strategy that will allow you to quickly and easily migrate from MicroLogix batch and safety control 1500 Controller to newer Controller platform. This approach will lower conversion time and engineering costs. *ACTIVE: Most current offering within a product category. ACTIVE MATURE: Product is fully supported, but a newer product or family exists. Gain value by migrating. END OF LIFE: Discontinued date announced actively execute migrations and last time buys. Product generally orderable until the discontinued DISCONTINUED: New product no longer manufactured or Repair/exchange services may be available.

4 1 - Outages on specific items may occur prior to the Discontinued date. 2 - Limited stock may be available in run-out mode, regionally. Supporting Your Migration With industry knowledge and worldwide service and support, Rockwell Automation will collaborate with you to help ensure a smooth transition from your MicroLogix 1500 controllers to either MicroLogix 1400 or CompactLogix controllers. Here's how: STEP 1: Plan Your Migration Once you planned your overall migration approach, let the Integrated Architecture Builder (IAB) help plan the details. The MicroLogix migration wizard that is embedded in IAB will step you through the system configuration process, helping you to decide on the components you prefer to keep and reuse, and the components you prefer to replace. Tools: Integrated Architecture Builder (IAB), SLC/ MicroLogix 1500 to CompactLogix Migration Guide (Publication 1769-AP001).

5 STEP 2: Application Code Conversion Save time and engineering resources by using the conversion utility for RSLogix Project Migrator. This tool converts your existing RSLogix 500 program to Logix project. Using this tool makes the conversion more cost effective and provides greater flexibility regarding the final product. Download this tool, which is a product add-on for Studio 5000 . environment, from the Product Compatibility and Download Center. Tools: RSLogix Project Migrator, SLC/ MicroLogix 1500 to CompactLogix Migration Guide (Publication 1769-AP001). MicroLogix 1500 Controller Compared to MicroLogix 1400 Controller and CompactLogix Controller MicroLogix 1500 MicroLogix 1400 CompactLogix 5370 L1 CompactLogix 5370 L2. Features Controller Controller Controller Controller Memory (in user words). Memory KB / 4 KB 1764-LSP, 10 K / 10 KB 384 KB / 512 KB (User memory) 750 KB / 1 MB (User memory).

6 (user program / user data) 10 KB / 4 KB 1764-LRP. Online editing N/A Yes Yes Yes Inputs/ Outputs Embedded Digital I/O, max 28 32 32 32. Four 0 10V DC inputs Four universal analog inputs Embedded Analog I/O N/A N/A. Two 0 10V DC outputs Two analog outputs Max. six / eight 1734 POINT. I/O Modules Local Expansion I/O Supported 512 256 Up to four 1769 I/O modules Use 1769-AENTR with 1769. I/O modules Multiple I/O module product lines Multiple I/O module product over DeviceNet via a DeviceNet network using lines over an EtherNet/IP . Networked Expansion I/O, max N/A 1769-SDN module and 1769-SDN scanner network via built-in EtherNet/IP. EtherNet/IP networks via built-in Network ports EtherNet/IP Network ports Added Functionality Trim Potentiometers 2 2 (digital) N/A N/A. PID Yes Yes Yes Yes Four embedded high-speed High Speed Counters (embedded) Two @ 20 kHz Up to six @ 100 kHz N/A.

7 Counters PWM Support 2 @ 20 kHz 3 @ 40 kHz N/A N/A. PTO Support 2 @ 20 kHz 3 @ 100 kHz AMCI 3601, 1 @ 1 MHz AMCI 3602, 2 @ 200 kHz Real-Time Clock Optional Yes Yes Yes Uses user program memory or Uses up to 64 KB data logging Recipe Storage Yes Yes 48 KB data logging memory memory Data Logging 48 KB 128 KB Yes Yes Floating Point Math Yes Yes Yes Yes Operating Power 120/240V AC Yes Yes N/A N/A. 24V DC Yes Yes Yes Yes Communication One RS-232 port RS-232 Ports Two RS-232 ports N/A N/A. One RS-232/RS-485 port USB Port N/A N/A 1 USB 1 USB. DeviceNet Peer-to-peer Messaging, With 1769-SDN N/A N/A With 1769-SDN. Slave I/O. With 1761-NET-ENI or EtherNet/IP Single EtherNet/IP port Dual-port EtherNet/IP support Dual-port EtherNet/IP support 1761-NET-ENIW. DH-485 Network with 1761-NET-AIC Network with 1763-NC01 N/A N/A. SCADA RTU - DF1 half-duplex SCADA RTU - DF1 Half-duplex Yes N/A N/A.

8 Master/slave SCADA RTU - DF1 Radio Modem Yes Yes N/A N/A. SCADA RTU - Modbus RTU. Yes Yes N/A N/A. Master/Slave Modbus TCP N/A Yes MVI69-MNET MVI69-MNET. Use 1734-232 ASC or ASCII - Read/Write Yes Yes Use 1769-ASCII. 1734-485 ASC. CIP Serial N/A N/A Yes Yes Agency Certifications CE, RCM, EAC, KC, UL, and C-UL. (including Class I, Division 2 Yes, except KC Yes, except KC Yes Yes Hazardous Locations). Allen-Bradley, CompactLogix, Listen. Think. Solve., MicroLogix , RSLogix 500, Studio 5000 and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication MIGRAT-PP015A-EN-E July 2015 Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. Supersedes Publication XXX-XXXXXX-XX-X Month 201X.


Related search queries