Example: biology

Micropulse Transducer BTL7 - djpautomacao.com

Object Detection Linear Position Sensing Industrial Identi cation Industrial Networking and Connectivity Micropulse + Transducer btl7 .. the new standard in industrial hydraulics Mechanical Accessories No. 861593 E Edition 0803; Subject to modification. Balluff GmbH. Schurwaldstrasse 9. 73765 Neuhausen Germany Phone +49 7158 173-0. Fax +49 7158 5010. standard as well as custom position switches. Innovative technology and application- specific customer solutions are the hallmarks of the entire product range. Highly qualified development engineers and experienced designers work closely with the manufacturing side to Balluff is a worldwide Wherever there is a need to By mastering process- ensure mature series leading company in the field automate, sense objects, or capable production and products that are used of position detection. Our report linear and rotary assembly techniques and successfully in every area of product lines include motion to controllers Balluff statistical process control automation even under electronic sensors, trans- is always the right partner.

BML Magnetic Linear Encoder Systems – Highly precise, long lengths BTL Micropulse Transducer/BIW Inductive Linear Position Sensors – Extremely rugged and reliable Photoelectric Distance Sensors – For any material or object color BIL Magneto-Inductive Distance Sensors – Compact and absolute BAW Inductive Distance Sensors – For short strikes ...

Tags:

  Sensor, Transducer, Magnetic, Micropulse, Btl7, Micropulse transducer btl7

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Micropulse Transducer BTL7 - djpautomacao.com

1 Object Detection Linear Position Sensing Industrial Identi cation Industrial Networking and Connectivity Micropulse + Transducer btl7 .. the new standard in industrial hydraulics Mechanical Accessories No. 861593 E Edition 0803; Subject to modification. Balluff GmbH. Schurwaldstrasse 9. 73765 Neuhausen Germany Phone +49 7158 173-0. Fax +49 7158 5010. standard as well as custom position switches. Innovative technology and application- specific customer solutions are the hallmarks of the entire product range. Highly qualified development engineers and experienced designers work closely with the manufacturing side to Balluff is a worldwide Wherever there is a need to By mastering process- ensure mature series leading company in the field automate, sense objects, or capable production and products that are used of position detection. Our report linear and rotary assembly techniques and successfully in every area of product lines include motion to controllers Balluff statistical process control automation even under electronic sensors, trans- is always the right partner.

2 We achieve consistently high extreme and aggressive ducers employing various product quality. Intensive operating conditions. operating principles, Our QM system meets the testing prior to series identification systems, bus- requirements of production ensures reliable capable sensors as well as DIN EN ISO 9001:2000. function. electromechanical and Eleven Balluff companies inductive multiple and single have a certified QM system, With more than 50 years of position switches. two a certified environmental experience in the field of Balluff products are found protection system. sensors, the Balluff Group is wherever accuracy and today one of the most reliability are demanded. capable manufacturers of BML magnetic Linear Encoder Systems Highly precise, long lengths BTL Micropulse Transducer /BIW Inductive Linear Position Sensors Extremely rugged and reliable Photoelectric Distance Sensors For any material or object color BIL Magneto-Inductive Distance Sensors Compact and absolute BAW Inductive Distance Sensors For short strikes Micropulse Transducers Overview of Linear Position Sensing i Greater flexibility through full range of sensing principles More efficiency through optimal solutions Increased productivity through well-engineered displacement sensing technology Displacement sensing.

3 The right solution for your application You work efficiently and need optimal solutions? For your displacement sensing Balluff gives you exactly what you need. Various operating principles are available: For distances of 1 to 48000 mm and re- solutions from 1 to 100 m. The choice is yours. Simply pick the system that's right for your. And let Balluff help add value to your process. Balluff displacement sensing technology: Rugged and designed for industry, precise and reliable, non-contact and wear-free 3. Micropulse The new standard Transducer in industrial hydraulics Micropulse +: Balluff displacement sensing The new standard in technology: Rugged and industrial hydraulics designed for industry, precise and reliable, non- Save time. Reduce your contact and wear-free production costs. The Micropulse + is up and More added value running in no time. Configure Save time with fast startup the parameters over a USB and simple parameter interface and profit from the setting easy setup.

4 Make full use of Increased reliability with the high functionality. And well-engineered use two freely programmable technology outputs. Status and dia- More efficiency through gnostic LEDs mean more high functionality security. Increased shock and vibration resistance guarantee reliable operation: More efficiency with Micropulse +. 4. Micropulse Contents Transducer Rod series 6 General data 8 Analog interface 12 Programming 14 Installation notes 15 Magnet 16 Connectors 19 Testing Laboratory btl7 . General data Analog interface Programming Installation notes Magnet Connectors Testing Laboratory 5. Micropulse General Data Transducer Rod series Pressure rated to 600 bar, Series btl7 Rod high repeatability, non-contacting, rugged Shock load 150 g/6 ms per IEC 60068-2-27. Vibration 20 g, Hz per EN 60068-2-6. The BTL Micropulse Polarity reversal protected yes Transducer is the rugged Overvoltage protection Transzorb protection diodes linear displacement system Dielectric strength 500 V AC (GND to housing).

5 For use under extreme Enclosure rating per IEC 60529 IP 68 for cable style, IP 67 for connector style (when connected). ambient conditions for Housing material Anodized stainless tube, stainless investment cast flange measuring ranges between Mounting Housing B thread M18 , housing Z 3/4"-16 UNF. 25 and 7600 mm. Pressure resistance with mm outer tube 600 bar when installed in hydraulic cylinder Pressure resistance with 8 mm outer tube 250 bar when installed in hydraulic cylinder The actual sensing element Connection type connector or integral cable (waveguide) is protected in a EMC tests: high pressure rated stainless RF emission EN 55011 Group 1, Class A and B. steel tube. The system is Static electricity (ESD) EN 61000-4-2 Severity Level 3. ideal for use in hydraulic Electromagnetic fields (RFI) EN 61000-4-3 Severity Level 3. cylinders for position feed- Rapid transients (BURST) EN 61000-4-4 Severity Level 3.

6 Back or for level control Withstand voltage (SURGE) EN 61000-4-5 Severity Level 2. in aggressive media in the Line-carried noise, EN 61000-4-6 Severity Level 3. foods and chemical induced by high-frequency fields industries. magnetic fields EN 61000-4-8 Severity Level 4. Standard nominals strokes [mm] 0025, 0050, 0075, 0100, 0125, 0150, 0175, 0200, for 8 mm rod the max. nominal 0225, 0250, 0275, 0300, 0325, 0350, 0375, 0400, stroke is 1016 mm 0425, 0450, 0475, 0500, 0550, 0600, 0650, 0700, 0750, 0800, 0850, 0900, 0950, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000, 2250, 2500, 2750, 3000, 3250, 3500, 3750, 3850, 4000, 4250, 4500, 4750, 5000, 5250, 5500, 5750, 6000, 6250, 6500, 6750, 7000, 7250, 7500, 7600 or in 5 mm increments (depending on steps) on request Please order separately: USB communication box page 13. Magnets page 15. Mounting nuts page 15.

7 Connectors starting page 16. Note! Before construction, installation and startup please familar yourself with the user's guide to be founded at 6. Micropulse General Data Shock and vibration resistant Transducer Rod series Series btl7 Rod Housing B Damping zone BTL7_ _ _ _ -B-_ _ _ _ (non-usable area). Nominal stroke = measuring area metric mounting thread M18 Magnet rd s eries t anda B=S. Thread M4 4/6 deep Thread Mounting surface btl7 . Housing Z Damping zone BTL7_ _ _ _ -Z-_ _ _ _ Nominal stroke = measuring area (non-usable area). 3/4" UNF mounting thread General data Magnet Analog interface Programming Installation Thread M4 4/6 deep notes Magnet Thread 3/4"x16 UNF. Connectors Testing Mounting surface Laboratory Housing B8 Damping zone BTL7_ _ _ _ -B8-_ _ _ _ (non-usable area). Nominal stroke = measuring area Metric mounting thread M18 8 mm tube max. 1016 mm nominal stroke Thread Mounting surface Housing Z8 Damping zone BTL7_ _ _ _ -Z8-_ _ _ _ (non-usable area).

8 Nominal stroke = measuring area 3/4" UNF mounting thread 8 mm tube max. 1016 mm nominal stroke Thread 3/4"x16 UNF. Mounting surface Housing A Damping zone btl7 -_ _ _ _-A-_ _ _ _ (non-usable area). Nominal stroke = measuring area Metric mounting thread M18 25 mm mounting Flange without . surface Thread M4 4/6 deep Thread Mounting surface 7. Micropulse Analog Interface Transducer Rod series Series btl7 Rod Output signal analog Transducer interface A. Input interface analog Features of Micropulse btl7 -A/C/ Status LEDs for indicating operating status and diagnostics Extended application range with high enclosure rating IP 68 (cable version). Electronics head can be replaced if needed Short housing, saves space Error signal, no magnet in range Flexible measuring range Ordering code btl7 -A110-M_ _ _ The start and end point of the active stroke can be set Output voltage V and V.

9 As needed in the application. Output current The points are set using the Load current max. 5 mA. included calibration device max. ripple Vpp directly on the unit or Load resistance remotely, see page 12. System resolution mV. Hysteresis 5 m Repeatability System resolution/min. 2 m Sampling rate length-dependent max. 4 kHz max. non-linearity 50 m to 500 mm nominal stroke % FS > 5500 mm nominal stroke % FS > 5500 mm nominal stroke Temperature coefficient 30 ppm/K. Supply voltage V DC. Current draw at 24 V DC 150 mA. Polarity reversal protected yes Overvoltage protection yes Dielectric constant 500 V AC (ground to housing). Operating temperature +85 C. Connect shield to housing .. Included: Please enter code for output Transducer signal, nominal stroke, housing Calibration device style and connection type in Short user's guide the order code! . Please order separately: Preferred models USB communication box page 13 Interfaces A110 and E100.

10 Magnets page 15 btl7 -A110-M_ _ _ _-B-S32, Mounting nuts page 15 btl7 -E100-M_ _ _ _-B-S32. Connectors starting page 16 highlighted in blue are available from stock. Note! Before construction, installation and startup please familar yourself with the user's guide to be founded at 8. Micropulse Analog Interface Compatible with BTL5 Transducer Rod series btl7 Rod btl7 Rod btl7 Rod analog analog analog G E C. analog analog analog btl7 . General data btl7 -G110-M_ _ _ btl7 -E1_0-M_ _ _ btl7 -C1_0-M_ _ _ Analog interface V and 10 V. Programming mA or mA mA or mA. Installation max. 5 mA. notes Vpp Magnet 500 Ohms 500 Ohms mV A A Connectors Testing Laboratory 5 m System resolution/min. 2 m max. 4 kHz 50 m to 500 mm nominal stroke % FS > 5500 mm nominal stroke % FS > 5500 mm nominal stroke 30 ppm/K. V DC. 150 mA. yes yes 500 V AC (ground to housing). +85 C. Ordering example: btl7 -_1_0-M_ _ _ _-_-_ _ _ _.


Related search queries