Example: barber

MIL-LT - Insulation Supply Company

MIL-LTVery flexible, flame-retardant, polyolefin heat-shrinkable tubingMIL-LT tubing is a very flexible, low-shrink-temperature, heat-shrinkable product for a variety ofmilitary applications. It meets therequirements of AMS-DTL-23053/5,Classes 1 and 3, and is used forinsulation, identification, strain relief,wire bundling, and color coding. MIL-LT tubing hot-stamps extremelywell. Made from flame-retardantpolyolefin, the tubing has excellentphysical, chemical, and electricalproperties that meet militaryrequirements for highly reliable,general-purpose tubing. Only a few sizes of MIL-LT tubing are required to cover many substrate ratingFull recovery temperature: 90 CContinuous operating temperature: 55 C to 135 CSpecifications*Type RaychemMilitaryMIL-LT RT-1171 AMS-DTL-23053, Cl. 1 and 3*When ordering, always specify latest informationColors StandardBlack, white, red, blue, yellow and greenNonstandardBrown, orange, violet, and graySize selection Always order the largest size that will shrink snugly over the component being packaging On spoolsOrdering description Specify product name, size, and color; for example, MIL-LT 1/4-0 (0=Black).

MIL-LT Very flexible, flame-retardant, polyolefin heat-shrinkable tubing MIL-LT tubing is a very flexible, low-shrink-temperature, heat-shrinkable product for a variety of

Tags:

  Mil lt

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of MIL-LT - Insulation Supply Company

1 MIL-LTVery flexible, flame-retardant, polyolefin heat-shrinkable tubingMIL-LT tubing is a very flexible, low-shrink-temperature, heat-shrinkable product for a variety ofmilitary applications. It meets therequirements of AMS-DTL-23053/5,Classes 1 and 3, and is used forinsulation, identification, strain relief,wire bundling, and color coding. MIL-LT tubing hot-stamps extremelywell. Made from flame-retardantpolyolefin, the tubing has excellentphysical, chemical, and electricalproperties that meet militaryrequirements for highly reliable,general-purpose tubing. Only a few sizes of MIL-LT tubing are required to cover many substrate ratingFull recovery temperature: 90 CContinuous operating temperature: 55 C to 135 CSpecifications*Type RaychemMilitaryMIL-LT RT-1171 AMS-DTL-23053, Cl. 1 and 3*When ordering, always specify latest informationColors StandardBlack, white, red, blue, yellow and greenNonstandardBrown, orange, violet, and graySize selection Always order the largest size that will shrink snugly over the component being packaging On spoolsOrdering description Specify product name, size, and color; for example, MIL-LT 1/4-0 (0=Black).

2 Dimensions (millimeters/inches)Inside diameterWall thicknessD (min.) d (max.) WExpanded Recovered RecoveredSize as supplied after heatingafter heating**3/64 **Wall thickness will be less if tubing recovery is restricted during diameterWall thicknessD (min.) d (max.) WExpanded Recovered RecoveredSize as supplied after heatingafter heating**1/2 1/2 recovered after heatingDWdExpanded as suppliedTyco Electronics Corporation300 Constitution DriveFaraday Road3816 Noborito, Tama-kuAsia Pacific HeadquartersMenlo Park, CA 94025-1164 Dorcan, Swindon, SN3 5 HHKawasaki, Kanagawa 214-853326 Ang Mo Kio, Industrial Park 2 USAU nited Kingdom JapanSingapore 569507 Tel: (800) 926-2425 (US & Canada)Tel: +44 1793 528171 Tel: +81 44 900 5102 Tel: +65 4866 151 Tel.

3 +1 (650) 361-3860 (All other countries)Users should independently evaluate the suitability of the product for their more information about this product visit information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics Corporation makesno warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics Corporation s only obligations are those in the Standard Terms andConditions of Sale for these products and in no case will Tyco Electronics Corporation be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of theproduct. Tyco Electronics Corporation s Specifications are subject to change without notice.

4 In addition, Tyco Electronics Corporation reserves the right to make changes in materials or processingwithout notification to the Buyer which do not affect compliance with any applicable specification. 1989, 1992, 1994, 1995, 2002 Tyco Electronics Corporation Printed in USA 1654060 6/02 Specification valuesProperty Unit Requirement Method of testPhysicalDimensions mm (inches) See reverse ASTM D 2671 Longitudinal change percent +0, 5 ASTM D 2671 Tensile strength psi (MPa)1500 ( )minimum ASTM D 2671 Ultimate elongation percent 200 minimum ASTM D 2671 Secant modulus (recovered) psi (MPa) x 104(89)maximum ASTM D 2671 Concentricity (expanded) percent 70 minimum ASTM D 2671 Restricted shrinkage No cracks ASTM D 2671 (30 minutes at 175 C/347 F) Procedure AProof voltage: 2000 V/a-cSpecific gravity (recovered) maximum ASTM D 2671 Low-temperature flexibility No cracking AMS-DTL-23053(4 hours at 55 C/ 67 F)Heat shock No dripping, flowing, ASTM D 2671(4 hours at 250 C/482 F) or crackingHeat resistance ASTM D 2671(168 hours at 175 C/347 F)Followed by tests for.

5 Tensile strength psi (MPa)1500 ( )minimum ASTM D 2671 Ultimate elongation percent 200 minimum ASTM D 2671 Color MIL-STD-104 MIL-STD-104 Color stability MIL-STD-104 ASTM D 2671(24 hours at 175 C/347 F)Shore A Hardness85 5 ASTM D 2240 ElectricalDielectric strength volts/mil (kV/mm)500 ( ) minimum ASTM D 2671 Volume resistivity ohm-cm 1014minimum ASTM D 2671 ChemicalCopper mirror corrosion Noncorrosive ASTM D 2671 (16 hours at 175 C/347 F) Procedure ACopper contact corrosion No pitting or blackening ASTM D 2671 (16 hours at 175 C/347 F) of copper Procedure BFlammability No flaming or glowing longer than 1 minute fromASTM D 2671 any flame application; 25% maximum flag burn;Procedure Cno burning of cotton.

6 Self-extinguishing within 15 seconds, no burning or charring of resistance Rating of 1 or less ASTM G 21 Water absorption (recovered)percent maximum ASTM D 2671(24 hours at 23 C/73 F)Fluid resistance ASTM D 2671(24 hours at 23 C/73 F) in:JP-8 fuel (MIL-T-5624)Skydrol 500 Hydraulic fluid (MIL-H-5606)Aviation gasoline 100/300 Lubricating oil (MIL-L-7808)Lubricating oil (MIL-L-23699)Deicing fluid (MIL-A-8243)5% NaClFollowed by tests for:Dielectric strength volts/mil (kV/mm) 400 ( )minimum ASTM D 2671 Tensile strength psi (MPa)1000 ( )minimum ASTM D 2671 Note: Consult RT-1171 for specific details about test is a trademark of Monsanto is a trademark of Tyco Electronics Corporation.