Example: bachelor of science

MINI Circuit Breakers Model VB3 - SNAP ACTION

mini Circuit BreakersModel VB3 Direct replacement for " ATO/ATC "automotive style fuses SPECIFICATIONSAmp Ratings : 3, 4, 5, 6, , 10, , 15, 20, 25, Ratings : 14 VDC ; 28 VDC Operating Temperature: -40 F to 185 F (-40 C to 85 C). Storage Temperature : -40 F to 260 F (-40 C to 125 C). Housing : UL Rated 94 VO Thermoplastic ( Non - Conductive housing eliminates dangers of internal parts shorting to case ). Terminal Type : Compatible with ATO/ATC fuse blocks Versions : Type I Automatic reset Type III Manual resetApprovals : Meets or exceeds SAE standard J553 Type I and Type III Circuit vs. C urrent1000900800700600500400300200100135 0 PERCENT OF RATED * MUST HOLD 100 % @ 25 & 70 degrees C 150 % overload = - 47 seconds 175 % overload = - seconds *200 % overload = - seconds 250 % overload = - seconds 300 % overload = - seconds 400 % overload = - seconds 500 % overload = - seconds TRIP TIME IN SECONDS :1260 WestMountainside, 07092 TIPWHITE (F 25).

MINI Circuit Breakers Model VB3 Direct replacement for " ATO/ATC "automotive style fuses SPECIFICATIONS Amp Ratings: 3, 4, 5, 6, 7.5, 10, 12.5, 15, 20, 25, 30 ...

Tags:

  Model, Breaker, Mini, Circuit, Mini circuit breakers model vb3

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of MINI Circuit Breakers Model VB3 - SNAP ACTION

1 mini Circuit BreakersModel VB3 Direct replacement for " ATO/ATC "automotive style fuses SPECIFICATIONSAmp Ratings : 3, 4, 5, 6, , 10, , 15, 20, 25, Ratings : 14 VDC ; 28 VDC Operating Temperature: -40 F to 185 F (-40 C to 85 C). Storage Temperature : -40 F to 260 F (-40 C to 125 C). Housing : UL Rated 94 VO Thermoplastic ( Non - Conductive housing eliminates dangers of internal parts shorting to case ). Terminal Type : Compatible with ATO/ATC fuse blocks Versions : Type I Automatic reset Type III Manual resetApprovals : Meets or exceeds SAE standard J553 Type I and Type III Circuit vs. C urrent1000900800700600500400300200100135 0 PERCENT OF RATED * MUST HOLD 100 % @ 25 & 70 degrees C 150 % overload = - 47 seconds 175 % overload = - seconds *200 % overload = - seconds 250 % overload = - seconds 300 % overload = - seconds 400 % overload = - seconds 500 % overload = - seconds TRIP TIME IN SECONDS :1260 WestMountainside, 07092 TIPWHITE (F 25).

2 330(F 33).570(F 57 Standard) Model NumberAmpRating Type ResetTerminal Style 3 4 5 6 101215202530VB3 Automatic Reset (Type I)F25F33F5720 AMPAUTORESET20 PUSHRESETAMPM anual Reset (Type III)Ordering InformationAutomatic Reset ( Type I )Remote Reset (Type II )AR==-Upon over load the breaker cycles continuosly during an over load condition until the over load is removed or over load the breaker opens and remains open as long as power is available or the over load is Reset (Type III ) = M-Upon over load the breaker opens and remains open until the breaker is IN