Example: stock market

Miniature Circuit Breakers & Residual Current Devices - Elinex

Leader in Electrics & Automation Miniature Circuit Breakers &. Residual Current Devices BKP / BKN / BKN-b / BKH / BF / RKP / RKS / RKN /. 32 KGR / BKD / BKD / Fb / BS & GR. Electric Equipment MCB. Miniature Circuit Breakers &. Residual Current Devices Contents General characteristics General description for residential Breakers Miniature Circuit Breakers 1, 2, 3 and 4pole series up to 125AF. - BKP. 6. 8. - BKN, BKN-b, BKH 9. Miniature Circuit Breakers 60mm depth Miniature Circuit Breakers , BF Series 10. - BF-a, BF-c 10. - BF, BFa-LUG, BF-PLUG 11. Residual Current Circuit Breakers - RKP, RKN 12. - 32 KGRa, 32 KGRb, BKD 13. Miniature Circuit Breakers DIN rail mounting - BKP type 14. - BKN type 15. - BKN-b type 22. - BKH type 29. - Residual Current Circuit Breakers , RKP & KGR type 30.

- Residual current circuit breakers, RKP & KGR type 30 - Residual current circuit breakers, RKN type 32 - Switch disconnector, BKD type 33 Residential Breakers Bolt on mounting - 60mm depth twin breakers, ABS-Fb & EBS-Fb type 34 - 60mm depth miniature circuit breakers, BF type 36 - 60mm depth & Lug terminal connection 38

Tags:

  Current, Circuit, Residual, Residual current, Residual current circuit

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Miniature Circuit Breakers & Residual Current Devices - Elinex

1 Leader in Electrics & Automation Miniature Circuit Breakers &. Residual Current Devices BKP / BKN / BKN-b / BKH / BF / RKP / RKS / RKN /. 32 KGR / BKD / BKD / Fb / BS & GR. Electric Equipment MCB. Miniature Circuit Breakers &. Residual Current Devices Contents General characteristics General description for residential Breakers Miniature Circuit Breakers 1, 2, 3 and 4pole series up to 125AF. - BKP. 6. 8. - BKN, BKN-b, BKH 9. Miniature Circuit Breakers 60mm depth Miniature Circuit Breakers , BF Series 10. - BF-a, BF-c 10. - BF, BFa-LUG, BF-PLUG 11. Residual Current Circuit Breakers - RKP, RKN 12. - 32 KGRa, 32 KGRb, BKD 13. Miniature Circuit Breakers DIN rail mounting - BKP type 14. - BKN type 15. - BKN-b type 22. - BKH type 29. - Residual Current Circuit Breakers , RKP & KGR type 30.

2 - Residual Current Circuit Breakers , RKN type 32. - Switch disconnector, BKD type 33. Residential Breakers Bolt on mounting - 60mm depth twin Breakers , ABS-Fb & EBS-Fb type 34. - 60mm depth Miniature Circuit Breakers , BF type 36. - 60mm depth & Lug terminal connection 38. - 42mm depth twin Breakers , BS & GR type 40. Standard busbars 42. Operating curves & temperature compensation - BKP, BKN, BKN-b, BKH, RKP, 32 KGRa, 32 KGRb 43. - ABS32Fb, ABS33Fb, ABS52Fb, ABS53Fb, EBS32Fb, 44. EBS33Fb, EBS52Fb, EBS53Fb, ABS52Fb, ABS53Fb, EBS52Fb, EBS53Fb - ABS102Fb, ABS103Fb, EBS102Fb, EBS103Fb, BS-31a, BS-32a 45. - BF-a, BF-c, BF 46. - BFa-LUG, BF-PLUG 47. - 32 GRa, 32 GRh, 33GR, 52 GRa 48. Overall dimensions - BKP, BKN, BKN-b, BKH 49. - RKP, RKN, 32 KGRa, BKD 50.

3 - ABS32Fb, ABS33Fb, ABS52Fb, ABS53Fb, 51. EBS32Fb, EBS33Fb, EBS52Fb, EBS53Fb - ABS102Fb, ABS103Fb, EBS102Fb, EBS103Fb 52. - BF-a, BF-c 53. - BF 54. - BFa-LUG, BF-PLUG 55. - BS-31a, BS-32a, BS-33 56. - 52 GRa, 32 GRa, 33GR, 30 GRh, 32 GRh 57. Environmental policy and RoHS compliance What is RoHS? The RoHS (Restriction of Hazardous Substances) is an EU. Directive that specifically identifies six key materials so that manufacturers are held responsible for ensuring that their products contain controlled concentrations of the six substances restricted by the Directive. The Six Hazardous Substances: Below 1,000ppm of Lead (Pb), Mercury (Hg), Hexavalent Chromium (Cr+6), Polybrominated Biphenyls (PBB) and Polybrominated Biphenyl Ethers (PBDE), and below 100ppm of Cadmium (Cd).

4 RoHS : Directive on the Restriction of Hazardous Substances in the Electronic Equipment (Effective on February 13, 2003). Application Products manufactured by LSIS do not directly apply to the RoHS Directive. However, small inverters imbedded in sport equipment and small Breakers in large home appliances can be indirectly applied to the Directive. LSIS continues to comply with the RoHS directive in order to establish environmentally Friendly management policies and global competitiveness for our products. According to the Law, eight of the 10 WEEE products excluding medical equipment' and control systems'. must be RoHS compliant. 4. 5. General characteristics General description for residential Breakers Miniature Circuit Breakers Type BKN-b Type BKN.

5 IEC60898 type MCB IEC60898 type MCB. 1 to 4pole up to 63A & 10kA 1 to 4pole up to 63A & 6kA. DIN rail mounting 45mm slot size width per pole see details (p. 22) see details (p. 15). Type BF. Type ABS-Fb American type MCB. 1 to 3pole up to IEC type MCCB. 100A & 10kA (BF-a) 2 & 3pole up to Bolt on 100A & 5kA (BF-c) 100A & 10kA. 50A & (BF). 50mm slot size 100A & 10kA. 60mm depth see details (p. 36) (BFa-LUG; 3 pole only) see details (p. 34). Type BS. Bolt on Economic type MCCB. 2 & 3pole up to 30A. 36mm slot size & 42mm depth see details (p. 40). Type BF-Plug Plug in 1 to 3pole up to 50A, 10kA. 56mm slot size Connection by 60mm depth lug terminal see details (p. 38). 6. Residual Current Circuit Breakers Type RKN Type KGR. IEC1008 type RCCB Electronic type RCCB.

6 2 & 4pole up to 63A 2pole up to 30A, I n=30, 100, 300mA I n=30mA. see details (p. 32) see details (p. 30). Type EBS-Fb Electronic type RCCB. 2 & 3pole up to 100A, 10kA. I n=30, 100mA. see details (p. 34). Type GR. Electronic type RCCB. 2 & 3pole up to 30A, I n=30mA. see details (p. 40). Slot 45mm Slot 50mm Slot 36mm 7. Miniature Circuit Breakers 1, 2, 3 and 4 Pole Series up to 125AF [IEC 60898, IEC 60947-2]. Type BKN BKN-b Protection Overload and short Circuit Overload and short Circuit Rated Current 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A. Characteristic B, C, D curve B, C, D curve Poles 1p, 1p+N, 2p, 3p, 3p+N, 4p 1p, 1p+N, 2p, 3p, 3p+N, 4p Breaking capacity 1pole 2~4pole 1pole 2~4pole 1A.

7 2A. 3A. 4A. 6A. 10A. 6kA at 6kA at 10kA at 10kA at 16A. 230/400 VAC 400 VAC 230/400 VAC 400 VAC. 20A. 25A. 32A. 40A. 50A. 63A. 80A. 100A. 125A. Standard IEC 60898 IEC 60898. Approval CCC, SABS, SEMKO CB CCC , KEMA CB, SABS, SEMKO CB, UL 1077. Type of trip Thermal magnetic release Thermal magnetic release Electrical endurance 6000 operations 8000 operations Mount On 35mm DIN rail On 35mm DIN rail Width per pole per pole Terminal Lug type(cable up to 25mm2) Lug type(cable up to 25mm2). Auxiliary switch, AX & AL 1 changeover contact 6A at 240 VAC, 3A at 415 VAC(AX). Optional 6A at 230 VAC, 3A at 415 VAC(AL). 2A at 48 VDC, 1A at 125 VDC. Lug terminal Cable capacity 9mm wide Dimension Characteristic curve See page 43 See page 43. Remarks UL 1077(240V 10kA).

8 8. MCB. BKH BKP BF-PLUG. Overload and short Circuit Overload and short Circuit Overload and short Circuit 63, 80, 100A, 125A 3, 6, 10, 16, 20, 25, 32A 10, 15, 20, 30, 40, 50A. C, D curve B, C, D curve 1P, 2P, 3P. 1p, 2p, 3p, 3p+N, 4p 1p+N 1P, 2P, 3P. 1pole 2~4pole at 230 VAC. 10kA at 120/240 VAC. 10kA at 10kA at 230/400 VAC 400 VAC. IEC 60947-2 IEC 60898 IEC 60947-2. CCC, CQC CB CCC, CQC CB. Thermal magnetic release Thermal magnetic release Thermal magnetic release 6000 operations 20000 operations 10, 000 operations On 35mm DIN rail On 35mm DIN rail Plug-in 27mm per pole 9mm per pole 25mm per pole Lug type(cable up to 50mm2) Lug type(cable up to 10mm2) Lug type (14-6 AWG.). ON ON ON. 63. 56. OFF OFF OFF. 81. 60 50. 65 75. 75. See page 43 See page 43 See page 47.

9 IEC 60947-2 (SABS). 9. Miniature Circuit Breakers 60mm depth Miniature Circuit Breakers , BF Series [IEC 60947-2]. Type BF-a Protection Overload and short Circuit Rated Current 10, 15, 20, 30, 40, 50, 60, 75, 100A. Poles 1P, 2P, 3P. Breaking capacity 1P 2P, 3P. 6A. 10A. 15A. 20A 10kA at 30A 240 VAC. 10kA at 40A. 240 VAC. 50A at 60A 415 VAC. 75A. 100A. Standard IEC 60947-2. Type of trip Thermal magnetic release Electrical endurance 10, 000 operations Mount Holder mounting Width 25mm per pole Terminal Clamp type Auxiliary switch, AX & AL. Optional Dimension Characteristic curve See page 46. 10. BF-Series BF-c BF BFa-LUG. Overload and short Circuit Overload and short Circuit Overload and short Circuit 10, 15, 20, 30, 40, 50, 60, 75, 100A 6, 10, 15, 20, 30, 40, 50A 10, 15, 20, 30, 40, 50, 60, 75, 100A.

10 1P, 2P, 3P 1P, 2P 3P. 1P 2P, 3P 1P, 2P 3P. 10kA at at 240 VAC. 5kA at 240 VAC. 240 VAC. 5kA at at 240 VAC 415 VAC. at 415 VAC. IEC 60947-2 IEC 60947-2 IEC 60947-2. Thermal magnetic release Thermal magnetic release Thermal magnetic release 10, 000 operations 10, 000 operations 10, 000 operations Holder mounting Holder mounting Holder mounting 25mm per pole 25mm per pole 75mm Clamp type Clamp type Lug type (14-1 AWG.). See page 46 See page 46 See page 46. 11. Residual Current Circuit Breakers 2 and 4pole series up to 63AF. RCBO RCCB. Type RKP RKS RKN. Protection Ground fault and overcurrent Ground fault and overcurrent Ground fault Rated Current , In 3(C, D), 6, 10, 16, 20, 25, 32A 6, 10, 16, 20, 25, 32A (B, C curve) 25, 32, 40, 63A. (B, C, D curve).


Related search queries