Transcription of Mining Anaconda Brand Mining-Grade Cables
1 1 MiningAnaconda BrandMining-Grade CablesAnaconda Brand Type G-GCPower, Round Portablew/Ground-Check, EPR/CPE7 Anaconda Brand Type G PlusGC Power, Round Portablew/Extensible Ground-Check,EPR/CPE8 Anaconda Brand Type SHDP ower, Flat Portable w/Ground,EPR/CPE9 Anaconda Brand TypeSHD-GC Power, ShieldedRound Portable w/Ground-Check, EPR/CPE10 Anaconda Brand Type SHDPlus GC Power, Shielded RoundPortable w/Extensible Ground-Check, EPR/CPE11 Anaconda Brand TypeSHD-PCG (Longwall) Power,Shielded Round Portablew/Monitor and/or ControlConductor(s), EPR/CPE12-13 Anaconda Brand TypeSHD-GC Power, ShieldedRound Portable w/Ground-Check, EPR/CPE14-17 Anaconda Brand Type MP-GC(Uniblend EPR), Mine PowerFeeder w/Ground-Check,EPR/CPE18-21 Anaconda Brand Type MP-GC,Mine Power Feeder w/Ground-Check, XLPE/PVC22 IndexPageAnaconda Brand Type WPower, Flat Parallel Portablew/o Ground, EPR/CPE2 Anaconda Brand Type WPower, Flat Parallel Portable,EPR/CPE3 Anaconda Brand Type WPower, Round Portable,EPR/CPE4 Anaconda Brand Type GPower, Flat Parallel Portablew/Ground, EPR/CPE5 Anaconda Brand Type G-GCPower, Flat Parallel Portablew/Ground-Check, EPR/CPE6 Anaconda Brand when itcomes to reliability andperformance in a Mining cable,one name stands Brand the world spremier extra-heavy-duty Mining -grade to endure the mostsevere and extreme demands ofthe toughest Mining a class by itself, AnacondaBrand sets the industry s highestperformance standard by whichall others are measured.
2 With areinforced, two-layer, lead-curedthermoset jacket, AnacondaBrand Mining Cables provide forthe ultimate in protection againstthe worst hazards and give newmeaning to dependable, durableand reliable. When the very bestis a basic requirement, there isonly one preferred choice, Anaconda Brand Mining Cables . Our Anaconda Brand Mining -grade products carry a full rangeof listings and certifications withMSHA and the CanadianStandard Association. Inaddition, the products meet orexceed the requirements of ICEAS75-381 Portable and Power-Feeder Cables for use in minesand similar advantage of GeneralCable s experience and expertisein Mining cable technologycontinues to provide practicalbenefits over the entire life cycleof a particular cable in a specificapplication. Better design andconstruction, more advancedmaterials and processtechnology, and more reliableperformance over a longer timeall result in lower cost per ton. Whatever the specificrequirement, General Cable canprovide the best performanceand best cost solution for anymining CableMining2 Anaconda Brand Type W Power, Flat Parallel Portablew/o Ground, EPR/CPE 2000 Volts 90 C, Two ConductorProduct Construction Conductor: 4 AWG thru 4/0 AWG coated annealed copper,bunched wires, rope-lay-stranded perASTM B172 Insulation: Ethylene Propylene Rubber (EPR) insulationcolored (black and white)Jacket: Extra-heavy-duty, lead-cured ChlorinatedPolyethylene (CPE)Jacket Marking: GENERAL CABLE Anaconda Brand (SIZE),2/C FLAT TYPE W 2000 VOLTS P-102-109 MSHAO ptions: Other jacket materials available upon requestApplications.
3 Designed for use as trailing Cables on DCmining equipment Designed for use where diode groundingis employed For battery charges and oil drilling x x x x x x * x x * x x * x x x x x x (AWG) AWG THRU 4/0 AWG CONDUCTORS, TWO CONDUCTOR, FLAT PARALLELPORTABLE W/O GROUND, TYPE W - 2000 * AUTHORIZED STOCK items are available in long lengths for cutting to your specifications. All lengths are subject to a tolerance of +/- 5%.Dimensions and weights shown are nominal, subject to standard industry tolerances. Actual shipping weight may ampacities are based on a conductor temperature of 90 C and an ambient air temperature of 40 C, per ICEA S-75-381, NEMA WC-58. For ampacitiesper National Electrical Code Requirements, refer to the latest NEC : Flat construction provides maximum resistance todamage from crushing and runovers D-shaped insulation prevents conductors fromshifting under the jacket Excellent physical toughness and heat stability Excellent heat, moisture, steam, oil, chemical,radiation and compression cut resistance Flexible for easy handling Resists cutting, impact, abrasion, flameand sunlight Excellent thermal stability and physical propertiesover a broad temperature rangeCompliances: ICEA S75-381 Portable and Power Feeder Cablesfor use in mines and similar applications Meets flame test requirements and is accepted forlisting by MSHA Approved by the Pennsylvania Department ofEnvironmental Protection Manufactured in accordance with 96 Portable Power Cables and is certified byNatural Resources CanadaPackaging.
4 Material cut to length and shipped on non-returnable reelsMining3 Mining -Grade CableAnaconda Brand Type W Power, Flat Parallel Portable,EPR/CPE 2000 Volts 90 C, Four Conductor6 AWG THRU 4/0 AWG CONDUCTORS, FOUR CONDUCTOR,FLAT PARALLEL PORTABLE, TYPE W - 2000 VOLTS* AUTHORIZED STOCK items are available in long lengths for cutting to your specifications. All lengths are subject to a tolerance of +/- 5%.Dimensions and weights shown are nominal, subject to standard industry tolerances. Actual shipping weight may ampacities are based on a conductor temperature of 90 C and an ambient air temperature of 40 C, per ICEA S-75-381, NEMA WC-58. For ampacitiesper National Electrical Code Requirements, refer to the latest NEC * x x * x x 1185176410442* x x * x x x x x x x x x x (AWG) (con t): Excellent heat, moisture, steam, oil, chemical,radiation and compression cut resistance Flexible for easy handling Resists cutting, impact, abrasion, flameand sunlight Excellent thermal stability and physicalproperties over a broad temperature range Compliances: ICEA S75-381 Portable and Power FeederCables for use in mines and similar applications Meets flame test requirements and accepted forlisting by MSHA Approved by the Pennsylvania Department ofEnvironmental Protection Manufactured in accordance with No.
5 96 Portable Power Cables and iscertified by Natural Resources CanadaPackaging: Material cut to length and shipped on non-returnable reelsProduct ConstructionConductor: 6 AWG thru 4/0 AWG coated annealed copper,bunched wires, rope-lay-stranded perASTM B172 Insulation: Ethylene Propylene Rubber (EPR) insulationcolored (black, white, red and green)Jacket: Extra-heavy-duty, lead-cured ChlorinatedPolyethylene (CPE)Jacket Marking: GENERAL CABLE Anaconda Brand (SIZE),4/C FLAT TYPE W 2000 VOLTS P-102-109 MSHAO ptions: Other jacket materials available upon requestApplications: Designed for use as trailing Cables on AC miningequipment:-Where a ground-check-conductor is notrequired for fail-safe ground monitoring-Where induced voltages in the groundingsystem do not present a hazardFeatures: Flat construction provides maximum resistance todamage from crushing and runovers Distributes tensile load uniformly among fourconductors Shaped insulation to prevent conductors fromshifting under the jacket Excellent physical toughness and heat stabilityNOMINALINSULATIONTHICKNESSINCHE SmmMining-Grade CableMining4 Anaconda Brand Type W Power, Round Portable, EPR/CPE2000 Volts 90 C, Four ConductorProduct ConstructionConductor: 6 AWG thru 500 kcmil coated annealed copper,bunched wires, rope-lay-stranded perASTM B172 Insulation: Ethylene Propylene Rubber (EPR) insulationcolored (black, white, red and green)Jacket: Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE)Jacket Marking: GENERAL CABLE Anaconda Brand (SIZE),4/C TYPE W 2000 VOLTS (-50 C) FT1 FT5 CSALR27161 P-7K102-045 MSHAO ptions: Other jacket materials available upon requestApplications.
6 Designed for use as trailing Cables on AC miningequipment:-Where a ground-check-conductor is not required for fail-safe ground monitoring-Where induced voltages do not present aproblemFeatures: Rope-lay-stranded conductors are extremelyflexible and resistant to wire breakage Excellent heat, moisture, steam, oil, chemicaland radiation resistance Flexible for easy handling Resists cutting, impact, abrasion, flameand sunlight Excellent thermal stability and physicalproperties over a broad temperature range Two-layer jacket is reinforced to providemaximum protection from mechanical damage the cause of most portable cable failuresCompliances: ICEA S75-381 Portable and Power FeederCables for use in mines and similar applications Meets flame test requirements and is acceptedfor listing by MSHA Approved by the Pennsylvania Department ofEnvironmental Protection Manufactured in accordance with No. 96 Portable Power Cables and iscertified by Natural Resources CanadaPackaging: Material cut to length and shipped on non-returnable reels46* * * * * 15441487NO.
7 (AWG/kcmil) AWG THRU 500 KCMIL CONDUCTORS, FOUR CONDUCTOR,ROUND PORTABLE, TYPE W - 2000 * AUTHORIZED STOCK items are available in long lengths for cutting to your specifications. All lengths are subject to a tolerance of +/- 5%.Dimensions and weights shown are nominal, subject to standard industry tolerances. Actual shipping weight may ampacities are based on a conductor temperature of 90 C and an ambient air temperature of 40 C, per ICEA S-75-381,NEMA WC-58. For ampacities per National Electrical Code Requirements, refer to the latest NEC CableAnaconda Brand Type G Power, Flat Parallel Portablew/Ground, EPR/CPE 2000 Volts 90 C, Two x x x x 117014522* x x 139016721* x x 1185 176019121/0* x x 1470 219021722 x x 1790 266025023 x x 2145 319028624 x x 2545 3790328NO. (AWG) (AWG) NETWEIGHTlbs/ AWG THRU 4/0 AWG CONDUCTORS, TWO CONDUCTOR,FLAT PARALLEL PORTABLE W/GROUND, TYPE G - 2000 VOLTS* AUTHORIZED STOCK items are available in long lengths for cutting to your specifications.
8 All lengths are subject to a tolerance of +/- 5%.Dimensions and weights shown are nominal, subject to standard industry tolerances. Actual shipping weight may ampacities are based on a conductor temperature of 90 C and an ambient air temperature of 40 C, per ICEA S-75-381, NEMA WC-58. For ampacitiesper National Electrical Code Requirements, refer to the latest NEC : Flat construction provides maximum resistanceto damage from crushing and runovers D-shaped insulation prevents conductors fromshifting under the jacket Excellent physical toughness and heat stability Excellent heat, moisture, steam, oil, chemical,radiation and compression cut resistance Flexible for easy handling Resists cutting, impact, abrasion, flameand sunlight Excellent thermal stability and physicalproperties over a broad temperature rangeCompliances: ICEA S75-381 Portable and Power FeederCables for use in mines and similar applications Meets flame test requirements and is acceptedfor listing by MSHA Approved by the Pennsylvania Department ofEnvironmental Protection Manufactured in accordance with No.
9 96 Portable Power Cables and iscertified by Natural Resources CanadaPackaging: Material cut to length and shipped on non-returnable reelsProduct Construction:Conductor: 4 AWG thru 4/0 AWG coated annealed copper,bunched wires, rope-lay-stranded perASTM B172 Insulation: Ethylene Propylene Rubber (EPR) insulationcolored (black and white)Grounding Conductor: Coated copper, rope-lay-stranded and shapedwith a green elastomer covering designed to keepthe grounding conductor in place in the flatassemblyJacket: Extra-heavy-duty, lead-cured ChlorinatedPolyethylene (CPE)Jacket Marking: GENERAL CABLE Anaconda Brand (SIZE),2/C FLAT TYPE G 2000 VOLTS P-102-109 MSHAO ptions: Other jacket materials available upon requestApplications: Designed for use as trailing Cables on DCmining equipment Designed for use where a grounding conductoris necessaryNOMINALINSULATIONTHICKNESSINCHE SmmMiningMining-Grade Cable6 Anaconda Brand Type G-GC Power, Flat Parallel Portablew/Ground-Check, EPR/CPE 2000 Volts 90 C, Three Conductor36* x x 13407934* x x 1175 175010433* x x 1395 208012032* x x 1625 241513831* x x 2090 311016131 x x 2470 367518632 x x 2940 437521533 x x 3515 523024934 x x 4245 6315287NO.
10 (AWG) (AWG)SIZEGRD-CHECKCOND.(AWG) AWG THRU 4/0 AWG CONDUCTORS, THREE CONDUCTOR,FLAT PARALLEL PORTABLE W/GROUND-CHECK, TYPE G-GC - 2000 VOLTS* AUTHORIZED STOCK items are available in long lengths for cutting to your specifications. All lengths are subject to a tolerance of +/- 5%.Dimensions and weights shown are nominal, subject to standard industry tolerances. Actual shipping weight may ampacities are based on a conductor temperature of 90 C and an ambient air temperature of 40 C, per ICEA S-75-381, NEMA WC-58. For ampacities perNational Electrical Code Requirements, refer to the latest NEC ConstructionConductor: 6 AWG thru 4/0 AWG coated annealed copper,bunched wires, rope-lay-stranded perASTM B172 Insulation: Ethylene Propylene Rubber (EPR) insulationcolored (black, white and red)Ground-Check-Conductor: Coated copper, rope-lay-stranded and shapedground-check-conductor is insulated with ayellow elastomerGrounding Conductor: Coated copper, rope-lay-stranded and shapedwith a green elastomer covering designed tokeep the grounding conductor in place in theflat assemblyJacket: Extra-heavy-duty, lead-cured ChlorinatedPolyethylene (CPE)Jacket Marking: GENERAL CABLE Anaconda Brand (SIZE), 3/CFLAT TYPE G-GC 2000 VOLTS P-102-109 MSHAO ptions: Other jacket materials available upon requestApplications: Designed for use as trailing Cables on AC miningequipment.