BULLETIN 3050-AMBULLETIN 3050-AMBULLETIN 3050-AMBULLETIN 3050-AMBULLETIN 3050-AMModel 3050-AM Moisture AnalyzerFEATURES Quartz-crystal technology provides accuracy,Quartz-crystal technology provides accuracy,Quartz-crystal technology provides accuracy,Quartz-crystal technology provides accuracy,Quartz-crystal technology provides accuracy,speed, and calibration stabilityspeed, and calibration stabilityspeed, and calibration stabilityspeed, and calibration stabilityspeed, and calibration stability On-line verification system confirms analyticalOn-line verification system confirms analyticalOn-line verification system confirms analyticalOn-line verification system confirms analyticalOn-line verification system confirms analyticalperformanceperformanceperforma nceperformanceperformance Intuitive, easy-to-use interface with keypad andIntuitive, easy-to-use interface with keypad andIntuitive, easy-to-use interface with keypad andIntuitive, easy-to-use interface with keypad andIntuitive, easy-to-use interface with keypad anddisplay allows quick access to all operatingdisplay allows quick access to all operatingdisplay allows quick access to all operatingdisplay allows quick access to all operatingdisplay allows quick access to all operatingvariablesvariablesvariablesvari ablesvariables Multi-gas compatibility is ideal for periodic testingMulti-gas compatibility is ideal

BULLETIN 3050-AM Model 3050-AM Moisture Analyzer FEATURES • Quartz-crystal technology provides accuracy, speed, and calibration stability • On-line verification system confirms analytical performance • Intuitive, easy-to-use interface with keypad and display allows quick access to all operating

Tags:

  Model, 3500, Analyzer, Moisture, Model 3050 am moisture analyzer

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Model 3050-AM Moisture Analyzer - Tectra

1 BULLETIN 3050-AMBULLETIN 3050-AMBULLETIN 3050-AMBULLETIN 3050-AMBULLETIN 3050-AMModel 3050-AM Moisture AnalyzerFEATURES Quartz-crystal technology provides accuracy,Quartz-crystal technology provides accuracy,Quartz-crystal technology provides accuracy,Quartz-crystal technology provides accuracy,Quartz-crystal technology provides accuracy,speed, and calibration stabilityspeed, and calibration stabilityspeed, and calibration stabilityspeed, and calibration stabilityspeed, and calibration stability On-line verification system confirms analyticalOn-line verification system confirms analyticalOn-line verification system confirms analyticalOn-line verification system confirms analyticalOn-line verification system confirms analyticalperformanceperformanceperforma nceperformanceperformance Intuitive, easy-to-use interface with keypad andIntuitive, easy-to-use interface with keypad andIntuitive, easy-to-use interface with keypad andIntuitive, easy-to-use interface with keypad andIntuitive.

2 Easy-to-use interface with keypad anddisplay allows quick access to all operatingdisplay allows quick access to all operatingdisplay allows quick access to all operatingdisplay allows quick access to all operatingdisplay allows quick access to all operatingvariablesvariablesvariablesvari ablesvariables Multi-gas compatibility is ideal for periodic testingMulti-gas compatibility is ideal for periodic testingMulti-gas compatibility is ideal for periodic testingMulti-gas compatibility is ideal for periodic testingMulti-gas compatibility is ideal for periodic testingof multiple sample gasesof multiple sample gasesof multiple sample gasesof multiple sample gasesof multiple sample gases Menu-driven gas selection eliminates all manualMenu-driven gas selection eliminates all manualMenu-driven gas selection eliminates all manualMenu-driven gas selection eliminates all manualMenu-driven gas selection eliminates all manualadjustmentsadjustmentsadjustmentsa djustmentsadjustmentsAMETEK s Model 3050-AM sets the ease-of-usestandard for accurate, ppmv Moisture analysis.

3 Thisanalyzer offers a truly remarkable combination ofperformance features: exceptional accuracy, multi-gascompatibility, fast response speed, and widemeasurement 3050-AM is ideal for process moisturemeasurement applications including process dryers,instrument air dryers, air separators, industrial gasproduction, and quality assurance. Equipped with anon-line verification system, this state-of-the-art analyzeris designed to rapidly build and maintain operatorconfidence in its analyses. The verification systemallows you to challenge the Analyzer s sensor at willusing a zero gas to check its baseline stability toconfirm the sensor s stability and sensitivity to sub-ppmv Moisture PERFORMANCEM ulti-gas compatibilityMulti-gas compatibilityMulti-gas compatibilityMulti-gas compatibilityMulti-gas compatibilityThe Model 3050-AM combines the excellent multi-gascompatibility of the Model 2850 with a new, easy-to-useoperator interface.

4 It is completely compatible withvirtually all non-corrosive gases including inerts (He, Ar,Ne, Xe, Kr), H2, O2, N2, NO, CO2, air, and many specialtygases such as sulfur hexafluoride. A single, simplemenu selection is all that is needed to re-configure the3050-AM for a new gas type. There are no othernecessary adjustments on the , if you want to analyze industrial, high purity, orsemiconductor grade gases and need an instrument thatis compatible with a wide range of gases, turn to theModel accuracyExceptional accuracyExceptional accuracyExceptional accuracyExceptional accuracyThe Model 3050-AM is perfect for Moisture applicationsthat require accurate results. The accuracy of thisanalyzer, +10% of reading, is exceptional when youconsider that a new aluminum oxide sensor is typicallyspecified with an accuracy of +72%/-57% of reading(converted from the dew point specifications) for amoisture concentration of ppmv at psia.

5 Quartz-crystal technology and an on-line verification systemcombine to constantly provide assurance that theanalyzer is continuing to provide you with this superiorlevel of 3050-AM Moisture AnalyzerModel 3050-AM Moisture AnalyzerModel 3050-AM Moisture AnalyzerModel 3050-AM Moisture AnalyzerModel 3050-AM Moisture AnalyzerOn-line verification system confirms analyticalOn-line verification system confirms analyticalOn-line verification system confirms analyticalOn-line verification system confirms analyticalOn-line verification system confirms analyticalperformanceperformanceperforma nceperformanceperformanceThe on-line verification system in the 3050-AM uses aninternal zero verification system. The zero verificationsystem strips the Moisture from the sample gas prior toanalysis by the sensor. This allows you to verify the zeropoint of the sensor s calibration, enhancing accuracyand user confidence when monitoring in the critical 0 to10 ppmv range.

6 This system is entirely internal to theanalyzer eliminating the need to break processconnections along with the "wet-up" that would occurfrom ambient Moisture . An alarm contact alerts theoperator if the Analyzer fails verification. The verificationsequences can be started on a programmable scheduleor on manual response speedFast response speedFast response speedFast response speedFast response speedThe Model 3050-AM responds quickly to both increasesand decreases in Moisture concentration because theanalyzer employs a unique non-equilibriummeasurement technique. This technique continuouslyexposes the sensor to wet sample gas followed by drysample gas to make its analysis. With this technique,the Analyzer never needs to wait for the sensor to reachequilibrium to establish its accurate , this technique is based upon the defined,repeatable physical properties of Moisture transport to/from the sensor s surface.

7 This means that quartz-crystal technology never employs the questionableprediction software often used to "speed-up" other,more limited s unique technique makes possibleaccurate Moisture readings far faster than would bepossible under equilibrium, or continuous "wet" samplegas, operating QUARTZ-CRYSTAL SENSORTHE QUARTZ-CRYSTAL SENSORTHE QUARTZ-CRYSTAL SENSORTHE QUARTZ-CRYSTAL SENSORTHE QUARTZ-CRYSTAL SENSORThe heart of the 3050-AM Analyzer is a quartz-crystal microbalance (QCM) sensorand analysis technique developed by AMETEK specifically for highly accuratemoisture measurements. The sensor consists of a pair of electrodes that support theQCM sensor. When voltage is applied to the sensor, a very stable oscillation faces of the oscillator are covered with a hygroscopic polymer. As theamount of Moisture sorbed onto the polymer varies, the mass of the QCM changesproducing a corresponding change in the frequency of oscillation.

8 These easilymeasurable changes have a direct relation to the Moisture concentration of thesample measurement rangeWide measurement rangeWide measurement rangeWide measurement rangeWide measurement rangeThe Model 3050-AM accurately measures from ppmvto 100 ppmv. While this is the recommended usablerange, the Analyzer will provide measurements up to1000 ppmv so that you can capture the nature of aprocess APPLICATIONSI ndustrial gas production and quality assuranceIndustrial gas production and quality assuranceIndustrial gas production and quality assuranceIndustrial gas production and quality assuranceIndustrial gas production and quality assuranceCompressed industrial gas suppliers need accuracy tocertify compressed gas quality. They need fast dry-down response to ensure that the Analyzer comes backon-line quickly after a slug of Moisture , and they needcomplete multi-gas compatibility.

9 Compare theperformance of your present Moisture Analyzer with theModel 3050-AM : exceptional accuracy, less than 5minute dry-down time in the 100 to 1 ppmv range, andcompatibility with virtually all compressed gases,including carbon dioxide and oxygen. Finally, oneanalyzer which meets all your analytical and air separationCryogenic air separationCryogenic air separationCryogenic air separationCryogenic air separationCryogenic separation produces inherently dry gas,typically on the order of a few hundred ppbv. Suddenlyincreasing Moisture is a widely used alarm conditionbecause of the danger of catastrophic freeze-up and thedowntime it causes. The Model 3050-AM answers thisneed perfectly with excellent sensitivity, fast responseto increasing Moisture , and reliable measurement in thecritical 100 ppbv to 1 ppmv alarm SPECIFICATIONSC ompatible Gases:Compatible Gases:Compatible Gases:Compatible Gases:Compatible Gases: Inerts (He, Ar, Ne, Xe, Kr), H2, O2, N2, NO,CO2, air, and some specialty gases such as sulfur requires a custom measurement cell.

10 (Contact the factoryto confirm compatibility with other gases.)Range:Range:Range:Range:Range: to 100 ppmv. Indicates trend to 1000 is software settable to show ppmv, or dew point(requires pressure input).Outputs:Outputs:Outputs:Outputs:O utputs:Four-line digital fully programmable 4-to-20 mA analog outputRS485/RS232 serial communicationAlarms:Alarms:Alarms:Alarms :Alarms: Three dry contact closures, 32 VDC maximum, 1 Anoninductive load ( Moisture , data valid, and system alarm).Alarm signals are available on the RS485 of Detection: Limit of Detection: Limit of Detection: Limit of Detection: Limit of Detection: ppmvAccuracy:Accuracy:Accuracy:Accuracy: Accuracy: 10% of the reading, whichever is greaterResponse Time:Response Time:Response Time:Response Time:Response Time: 63% in 5 minutes (as measured for a 0 5ppmv step change)Inlet Pressure: Inlet Pressure: Inlet Pressure: Inlet Pressure: Inlet Pressure: 20 to 50 psig ( to bar)Exhaust Pressure: Exhaust Pressure: Exhaust Pressure: Exhaust Pressure: Exhaust Pressure: AtmosphericSample Flow Requirements:Sample Flow Requirements:Sample Flow Requirements:Sample Flow Requirements:Sample Flow Requirements: less than 150 ml/min at STPS ample Gas Temperature: Sample Gas Temperature: Sample Gas Temperature: Sample Gas Temperature: Sample Gas Temperature: 32 to 212 F (0 to 100 C)Ambient Operating Range:Ambient Operating Range.