Example: bankruptcy

Model 3051 Pressure Transmitter - Instrumart

Manual 00809-0100-4001, Rev EADecember 2002 Model 3051 Pressure Transmitterwith HART protocol Reference Manual 00809-0100-4001, Rev EADecember 2002 Model 3051 Pressure TransmitterRosemount Model 3051 Smart Pressure Transmitters may be protected by one or more of the following: Patent Nos. 4466290; 4612812; 4791352; 4798089; 4818994; 4866435; 4878012; 4988990; 4926340; 5083091; 5122794; 5166678; 5248167; 5278543; 5287746; 5329818; 5333504; 5585777; 6017143; 6119047; 6295875; Des. 317266; Des. 318432; Des 342456.

Reference Manual 00809-0100-4001, Rev EA December 2002 Model 3051 www.rosemount.com Model 3051 Pressure Transmitter Rosemount Model 3051 Smart Pressure Transmitters may be protected by one or more of the

Tags:

  Model, Pressure, Transmitter, 3051, Model 3051 pressure transmitter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Model 3051 Pressure Transmitter - Instrumart

1 Manual 00809-0100-4001, Rev EADecember 2002 Model 3051 Pressure Transmitterwith HART protocol Reference Manual 00809-0100-4001, Rev EADecember 2002 Model 3051 Pressure TransmitterRosemount Model 3051 Smart Pressure Transmitters may be protected by one or more of the following: Patent Nos. 4466290; 4612812; 4791352; 4798089; 4818994; 4866435; 4878012; 4988990; 4926340; 5083091; 5122794; 5166678; 5248167; 5278543; 5287746; 5329818; 5333504; 5585777; 6017143; 6119047; 6295875; Des. 317266; Des. 318432; Des 342456.

2 May depend on Model . Other and foreign patents issued and this manual before working with the product. For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining this the United States, Rosemount Inc. has two toll-free assistance numbers:Customer CentralTechnical support, quoting, and order-related (7:00 am to 7:00 pm CST)North American Response CenterEquipment service (24 hours includes Canada)Outside of the United States, contact your local Rosemount products described in this document are NOT designed for nuclear-qualified applications.

3 Using non-nuclear qualified products in applications that require nuclear-qualified hardware or products may cause inaccurate information on Rosemount nuclear-qualified products, contact your local Rosemount Sales satisfies all obligations coming from legislation to harmonize product requirements in the European Manual 00809-0100-4001, Rev EADecember 2002 Model of ContentsSECTION 1 IntroductionUsing This Manual.. 1-1 Service Support .. 1-1 Models Covered.. 1-2 Transmitter Overview.. 1-3 SECTION 2 InstallationOverview.

4 2-1 Safety Messages .. 2-1 Warnings .. 2-1 General Considerations.. 2-2 Mechanical Considerations .. 2-3 Draft Range Considerations .. 2-3 Environmental Considerations.. 2-4 Installation Procedures .. 2-6 Mount the Transmitter .. 2-6 Process Connections .. 2-11 Consider Housing Rotation.. 2-13 Set Jumpers .. 2-14 Connect Wiring and Power Up .. 2-16 Hazardous Locations.. 2-18 Grounding theTransmitter Case .. 2-18 Installing theLCD Display.. 2-19 Models 305 and 306 Integral Manifolds.. 2-22 Installation Procedure.

5 2-22 SECTION 3 ConfigurationOverview .. 3-1 Safety Messages .. 3-1 Warnings .. 3-1 Commissioning on the bench with HART .. 3-2 Setting the Loop to Manual.. 3-2 Wiring Diagrams.. 3-3 Model 275 HART Communicator.. 3-4 Review Configuration Data .. 3-7 Check Output.. 3-7 Process Variables.. 3-7 Sensor Temperature.. 3-8 Basic Setup .. 3-8 Set Process Variable Units.. 3-8 Set Output .. 3-9 Rerange .. 3-10 Damping .. 3-16 Reference Manual00809-0100-4001, Rev EADecember 2002 Model 3051 TOC-2 LCD Display.. 3-16 Standard display Configuration.

6 3-17 Custom display Configuration.. 3-17 Detailed Setup .. 3-19 Failure Mode Alarm and Saturation .. 3-19 Alarm and Saturation Levels for Burst Mode .. 3-20 Alarm and Saturation Values for Multidrop Mode.. 3-20 Alarm Level Verification .. 3-20 Sensor Temperature Unit .. 3-20 Diagnostics and Service .. 3-21 Transmitter Test .. 3-21 Loop Test .. 3-21 Advanced Functions .. 3-22 Saving, Recalling, and Cloning Configuration Data .. 3-22 Burst Mode .. 3-24 Multidrop Communication .. 3-25 Changing a Transmitter Address.

7 3-26 Communicating with a Multidropped Transmitter .. 3-27 Polling a Multidropped Transmitter .. 3-27 SECTION 4 Operation and MaintenanceOverview .. 4-1 Safety Messages .. 4-1 Warnings .. 4-1 Calibration .. 4-2 Calibration Overview .. 4-3 Determining Calibration Frequency .. 4-4 Choosing a Trim Procedure .. 4-6 Sensor Trim .. 4-6 Zero Trim .. 4-7 Full Trim .. 4-8 Recall Factory Trim .. 4-9 Analog Output Trim .. 4-10 Digital-to-Analog Trim.. 4-10 Digital-to-Analog Trim Using Other Scale.. 4-11 Compensating for Line Pressure .

8 4-12 Diagnostic Messages .. 4-14 Local Zero and Span (Local Keys) Software Lock Out.. 4-19 Physical Removal of Local Zero and Span (Local Keys) .. 4-19 Selecting Output Range for Low-Power .. 4-20 Detailed Setup .. 4-20 Local Span and Zero Control (Local Keys).. 4-20 SECTION 5 TroubleshootingOverview .. 5-1 Safety Messages .. 5-1 Warnings .. 5-1 Before Disassembling the Transmitter .. 5-3 Disassembly Procedures.. 5-3 Remove the Transmitter from Service .. 5-3 Remove the Terminal Block .. 5-4 Remove the Electronics Board.

9 5-4 Remove the Sensor Module from the Electronics Housing .. 5-5 Reference Manual 00809-0100-4001, Rev EADecember 2002 TOC-3 Model 3051 Reassembly Procedures .. 5-5 Attach the Electronics Board .. 5-6 Install the Terminal Block .. 5-6 Reassemble the Process Sensor Body .. 5-7 APPENDIX AReference InformationPerformance Specifications..A-1 Detailed Performance Specifications..A-2 Reference Accuracy ..A-2 Ambient Temperature..A-3 Line Pressure Effect ..A-4 Dynamic Performance ..A-4 Mounting Position Effects..A-5 Vibration Effect.

10 A-5 Power Supply Effect ..A-5 RFI Effects ..A-5 Transient Protection ..A-5 Functional Specifications..A-6 Range and Sensor Limits ..A-6 Physical Specifications ..A-11 Dimensional Drawings..A-13 Ordering Information ..A-21 Parts List ..A-35 Options ..A-45 HART Protocol Configuration Data Sheet ..A-50 APPENDIX BProduct CertificationsOverview ..B-1 Safety Messages ..B-1 Warnings ..B-1 Approved Manufacturing Locations ..B-2 European Directive Information ..B-2 ATEX Directive ..B-2 European Pressure Equipment Directive (PED) (97/23/EC).