Model 4000 Portable Vibration STANDARD …

STANDARD FEATURESM odel 4000 Portable VibrationCalibration TableThe Model 40000 Portable Vibration Calibration table is a Portable , battery operated calibration reference instrument that is ideal for testing field mounted Vibration transducers, cabling, and related accessories. The Model 4000 is a complete, self contained, Portable Vibration calibrator. As a STANDARD feature, each unit is equipped with it's own rechargeable power source. This makes the 4000 an excellent choice for any field calibration work where an extension cord is both dangerous and time consuming. An external charger/power supply provides charging and operational current when used in the lab. To ensure accuracy and the reliability of test readings, the Model 4000contains an integrated National Institute of Standards and Technology ((NIST) traceable reference accelerometer. The Model 4000 utilizes a uniquesuspension that can support sensors that weigh up to 500 grams without the aid of an external support any other Portable shaker system, the Model 4000 will allow the user to calibrate nearly all types of seismic transducers, no matter themanufacturer.)

STANDARD FEATURES Model 4000 Portable Vibration Calibration Table The Model 40000 Portable Vibration Calibration table is a portable, battery operated calibration reference instrument that is ideal for

Tags:

  Portable, 4000, Model, Vibration, Model 4000 portable vibration

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Model 4000 Portable Vibration STANDARD …

1 STANDARD FEATURESM odel 4000 Portable VibrationCalibration TableThe Model 40000 Portable Vibration Calibration table is a Portable , battery operated calibration reference instrument that is ideal for testing field mounted Vibration transducers, cabling, and related accessories. The Model 4000 is a complete, self contained, Portable Vibration calibrator. As a STANDARD feature, each unit is equipped with it's own rechargeable power source. This makes the 4000 an excellent choice for any field calibration work where an extension cord is both dangerous and time consuming. An external charger/power supply provides charging and operational current when used in the lab. To ensure accuracy and the reliability of test readings, the Model 4000contains an integrated National Institute of Standards and Technology ((NIST) traceable reference accelerometer. The Model 4000 utilizes a uniquesuspension that can support sensors that weigh up to 500 grams without the aid of an external support any other Portable shaker system, the Model 4000 will allow the user to calibrate nearly all types of seismic transducers, no matter themanufacturer.)

2 The S4A-1 Eddy Current Probe adapter and DialMicrometer can be used to verifyboth static and dynamic output, linear range of an individualEddy Current Probe, or an entire probe FEATURESP ower RequirementsInternal Batteries 12V, 4 Ampere HourAC POWER 105 to 265 V, 47 to 440 HzTemperature 0 to 50 CSize 12 X7 X12 Accelerometers, Velometers,Non Contact Proximity robes**Contact Factory For Additional Inputs**INPUTSDC Recorder Output forInternal referanceFULL SCALE OUTPUTS (DC)MOUNTINGFULL SCALE RANGEENVIRONMENTALA ccuracyAcceleration 30 Hz to 2 KHz +/-3%20 Hz to 10,000 kHz+/-1db1dbVelocity 30 Hz to 2 KHz +/-3%Displacement Units 30 Hz to 200Hz +/-3%10Hz-100Hz101Hz - Khz - 10 KHzTransducer mass can effect Frequency Full ScaleGilchrist Technology, Box 509, 1004 Hwy 87 Gilchrist, TX 77617 Phone: (409) 289-5221 Fax: (409) 286-2227 Contact Informatio