Example: tourism industry

Models 4528, 4528EZ, and 4728 Monitors CX-645 …

SPECIFICATIONS / PARTS LIST MEASUREMENT SOLUTIONS. Models 4528, 4528EZ, and 4728 Monitors CX-645 Probe . We put you first. Water Cut Monitors And keep you ahead. Bulletin SSIN015 Issue/Rev. (11/16). The INVALCO Model 4728 Water Cut Monitor, in conjunction with a Model 4528 Detector and a Model CX-645 Capacitance Probe is a continuous on-line monitor or percent water in a flowing crude oil emulsion stream. This unit displays percent of water in various ranges from 0-5% up to and including 0-20%. on a digital LCD indicator. In addition, the Model 4728 provides a 4-20 mA analog output proportional to input range, and a field-adjusted, time-delayed, limit relay for valve control or alarming. Key Features Real-Time Display and Retransmission of Water Cut Model 4728 Monitor Monitor and Model CX-645 Probe Allows quick response to upset conditions for downstream controls.

Key Features Applications The INVALCO Model 4728 Water Cut Monitor, in conjunction with a Model 4528 Detector and a Model CX-645 Capacitance Probe is a continuous on-line monitor or percent water in a

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Models 4528, 4528EZ, and 4728 Monitors CX-645 …

1 SPECIFICATIONS / PARTS LIST MEASUREMENT SOLUTIONS. Models 4528, 4528EZ, and 4728 Monitors CX-645 Probe . We put you first. Water Cut Monitors And keep you ahead. Bulletin SSIN015 Issue/Rev. (11/16). The INVALCO Model 4728 Water Cut Monitor, in conjunction with a Model 4528 Detector and a Model CX-645 Capacitance Probe is a continuous on-line monitor or percent water in a flowing crude oil emulsion stream. This unit displays percent of water in various ranges from 0-5% up to and including 0-20%. on a digital LCD indicator. In addition, the Model 4728 provides a 4-20 mA analog output proportional to input range, and a field-adjusted, time-delayed, limit relay for valve control or alarming. Key Features Real-Time Display and Retransmission of Water Cut Model 4728 Monitor Monitor and Model CX-645 Probe Allows quick response to upset conditions for downstream controls.

2 Adjustable Delay of Relay Closure Prevents nuisance alarms and actuator overload . Model 4728 Specifications Direct Analog Output from Model 4528 Detector Power Supply A 4- 20 mA signal is available from the probe without 18-28 Vdc @ 130 mA. the need to include the Model 4728 monitor. 115/220 Vac Nace adaptable Water Cut Monitor Full Scale Range Can be modified for use in NACE applications. 0-5%, 0-10%, and 0-20% range options. Display Applications Four digit LCD with decimal point. LACT (Lease Automatic Custody Transfer) Units Analog Outputs Detect and provide relay contact closure that can be used to reroute oil that has excess Water Cut. 4-20 mA, 2-wire internally powered or 4-20 mA, 3-wire externally powered. Pipeline Loading Relay Output Monitor transfer of petroleum/condensate products from loading facilities.

3 SPDT Relay, 10A, 250 Vac. Dehydration Equipment 1/2 Hp 250 Vac, 10A - 120 Vac resistive. 1/3 Hp 120 Vac, 10A - 30 Vdc resistive. Determine and enhance equipment efficiencies, by monitoring the product and indicating water content. Time Delay Fuel Oil Monitoring 0 to 90 seconds adjustable in 10 second increments. Determine contamination of fuel oil by condensation, Off-delay approximately 10% of on-delay time. or other external factors, before entry to engine. Temperature Range Storage and Treating Facilities 0 F to 160 F (-20 C to 70 C). Monitoring and early detection of undesirable conditions as well as interface detection during de- Enclosures watering of storage tanks. NEMA 4X, weatherproof. NEMA 7, explosion-proof, Class I, Division 1, Groups C and D. 1. Model 4728 Ordering Information Model Number Description Part Number Model 4728-PM 4728 Oil/Water Monitor, All Ranges, Panel Mount 81001148.

4 Model 4728-5WP 4728 Oil/Water Monitor, 0-5% range, Nema 4X - WP 81001114. Model 4728-5XP 4728 Oil/Water Monitor, 0-5% range, Nema 7 - XP 81001115. Model 4728-10WP 4728 Oil/Water Monitor, 0-10% range, Nema 4X - 81001126. WP. Model 4728-10XP 4728 Oil/Water Monitor, 0-10% range, Nema 7 - XP 81001116. Model 4728-20WP 4728 Oil/Water Monitor, 0-20% range, Nema 4X - 81001128. WP. Model 4728-20XP 4728 Oil/Water Monitor, 0-20% range, Nema 7 - XP 81001117. Model 4728 Dimensional Specifications Model 4728 Dimensional Specifications The Model 4528 Detector and Model CX-645 Probe provide a direct analog (0-5 Vdc or 4-20 mA) output of percent emulsified (175). 4 water (as Water Cut Monitor) in the process stream. This signal (101). NEMA 4X is designed to be used externally by the Model 4728 monitor or Weatherproof Housing other control devices such as PLC's or Remote Terminal Systems.

5 The probe is constructed of two concentric tubes. Wetted surfaces (226). 10 . are coated with a baked-on phenolic two-part epoxy. The inner (253). tube is insulated from the outer tube by Polytetrafluoroethylene (PTFE) spacers and is electrically connected to a terminal within the sensor housing. The internal element spacers can be fitted (112). with trimmer rods should it be necessary to adjust the base capacitance.. (166) (274). The detector operates from a 12 Vdc regulated power supply NEMA 7 from within the associated monitor or customer supplied Explosion-Proof Housing source. All calibration and adjustments can be accessed through . (258) the front panel for ease of use. The Model 4528 detector offers the flexibility of a high and low fail-safe. This fail-safe feature (222).

6 Guarantees the quality of the output signal from the detector chassis and will sense over- and under-range conditions as well as an open or shorted probe. (207). Note: Dimensions - Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings. 2. Detector/Probe Specifications CX-645 Capacitance Probe & Model 4528 Detector Power Supply Part Model Number Description 12 Vdc @ 130 mA for 0-5 Vdc output. Number 24 Vdc required for 4-20 mA output. Water Cut Monitor Detector Model 4528-5 for CX-645 probe, 0-5% range, 81001164. Water Cut Monitor Range 0-5 VDC output 0-5%, 0-10%, and 0-20%. Water Cut Monitor Detector Model 4528-5A for CX-645 probe, 0-5% range, 81001295. Measurement Accuracy 4-20mA output Water Cut Monitor Detector for of full scale.

7 Model 4528-10 CX-645 probe, 0-10% range, 81001160. 0-5 VDC output Resolution/Sensitivity Water Cut Monitor Detector for Model 4528 10A CX-645 probe, 0-10% range, 81001294. of full scale. 4-20mA output Probe Material Water Cut Monitor Detector for Model 4528-20 CX-645 probe, 0-20% range, 81001161. A53 GrB Carbon Steel is standard. (Stainless Steel 0-5 VDC output available.) Water Cut Monitor Detector for Probe Finish Model 4528-20A CX-645 probe, 0-20% range, 81001162. 4-20mA output Baked-on phenolic two-part epoxy. Model 4528 Test Kit 81000520. Water Cut Monitor Detector for Probe Material Model 4528EZ CX-645 probe, Field Selectable P518796. A53 GrB Carbon Steel is standard. (Stainless Steel Range 0-5%, 0-10%, 0-20% 3 Hour Illustration available.). Probe Sizes/Length FNPT. Conduit Connection 2 is 17 face-to-face.

8 Model 4528. 3 to 12 sizes are 32 face-to-face. Exp. Housing Dimension B . Process Connections Element (Inner Plate) Teflon Insulator ANSI RF or RTJ Flanges to 600# (all sizes) (others by special order). Threaded MNPT or Grooved (2 and 3 ). Model CX-645 . Pressure Ratings Trimmer Rod (If needed). Probe Body (Outer Plate) Capacitance Probe Dimension A & Model 4528 Detector As per Flange selection, 1440 psig max. NPT - 1440 psig max. (Victualic grooved - 350 psig). Temperature Range Size Dim A. Dim B. Weight (lb). 0 F to 165 F standard. (-20 F to 375 F optional.) 2 Inch (431) (247) 20. Approvals 3 Inch (811) (275) 45. 4 Inch (811) (301) 72. UL/C-UL Explosion-proof certificate for Class I, Div. 1, Groups C and D or Class II, Groups E, F, and G hazardous 6 Inch (811) (355) 127. locations.

9 8 Inch (811) (405) 190. 10 Inch (811) (459) 268. 12 Inch Consult Factory. *0 F to 180 F dimension given. For -20 F to 375 F. dimension add . 3. MEASUREMENT SOLUTIONS. Typical Applications We put you first. Capacitance Probe Model 4728. And keep you ahead. Model CX-645 & Oil/Water Monitor Percent Water Indication 4528 Detector Four and Set-Point Control Conductor Cable Analog In this application the adjustable Capacitance Probe Model 4728. Output Model CX-645 & Oil/Water Monitor alarm may be used to operate a 4528 Detector Analog Four Output diverter valve should the water Conductor Cable content exceed a preset percentage. Recorder, Solenoid Local indication is provided and an PLC/DCS. Diverter System Valve analog output for other indication or control functions is available.

10 CX-645 Capacitance Probe Ordering Information Percent Water Recording In this application the Model BWater Cut Monitor PROBE, Ranges from 0-20% water - to be used with Model 4728 provides local reading CX-645 4528 Detector PROBE MATERIAL: Carbon Steel on an LCD display and | CODE PROBE BODY SIZE provides an analog output | 2 2 INCH x 17 FACE TO FACE (4-20mA) to a standard | 3 3 INCH x 32" FACE TO FACE recorder, PLC, or DCS System. | 4 4 INCH x 32 FACE TO FACE This configuration is used to | 6 6 INCH x 32 FACE TO FACE. monitor and control Separator | 8 8 INCH x 32 FACE TO FACE. | | CODE END CONNECTIONS and Heater-Treater efficiencies | | 00 SCREWED ENDS (TO 3" ONLY) as well as other oil field and | | 00 GROOVED ENDS / VICTAULIC (TO 4" ONLY) industrial applications. | | 00 150 LB ANSI RAISED FACE.