T-285PL Rev ECarrierTransicoldContainerRefrigeration ServiceParts ListModels69NT40-511-300 to 30969NT40-511-311 to 399 Carrier Corporation 2001 DPrinted in U. S. A. 0401 Carrier Transicold, Carrier Corporation, Box 4805, Syracuse, 13221 U. S. Refrigeration Operations, A member of the United Technologies family. Stock symbol PARTS LISTCONTAINER REFRIGERATION UNITMODELS69NT40-511-300 to 30969NT40-511-311 to 399iT-285PL Rev ETABLE OF QUICK LIST -- Clamps, Filter-Drier, Fuses, Ty-Raps, and Wire REFRIGERATION UNIT Refrigeration Unit -- Area Rain Thermometer Control Box Control Box -- Aluminum or Control Box -- Standard Electrical Components, Remote Monitoring and Control Box -- Evaporator Fan Capability, EBS and EDS, EBS Only and Cond.

T-285PL Rev E Carrier Transicold Container Refrigeration Service Parts List Models 69NT40-511-300 to 309 69NT40-511-311 to 399

Tags:

  Model, Models 69nt40 511 300 to, 69nt40

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Models 69NT40-511-300 to 309 69NT40-511-311 to 399

1 T-285PL Rev ECarrierTransicoldContainerRefrigeration ServiceParts ListModels69NT40-511-300 to 30969NT40-511-311 to 399 Carrier Corporation 2001 DPrinted in U. S. A. 0401 Carrier Transicold, Carrier Corporation, Box 4805, Syracuse, 13221 U. S. Refrigeration Operations, A member of the United Technologies family. Stock symbol PARTS LISTCONTAINER REFRIGERATION UNITMODELS69NT40-511-300 to 30969NT40-511-311 to 399iT-285PL Rev ETABLE OF QUICK LIST -- Clamps, Filter-Drier, Fuses, Ty-Raps, and Wire REFRIGERATION UNIT Refrigeration Unit -- Area Rain Thermometer Control Box Control Box -- Aluminum or Control Box -- Standard Electrical Components, Remote Monitoring and Control Box -- Evaporator Fan Capability, EBS and EDS, EBS Only and Cond.

2 Fan Control Box -- Controller Module Section and Software Control Box -- Display Module and Communications Interface Module Condenser Fan Motor, Condenser Coil, and Bolted or Hinged Grille Compressor Tubing Receiver Water--Cooled STS and SRS Thermostatic Expansion Valve (TXV), Alco or Upper Fresh Air Makeup and Access Lower Fresh Air Makeup Evaporator Fan Assembly and Evaporator Coil USDA Option, Probe Back Panel Assembly -- Aluminum Back Panel Assembly -- Aluminum Bolted with USDA Back Panel Assembly -- Aluminum Bolted with Probe Access Back Panel Assembly -- Aluminum Back Panel Assembly -- Stainless Steel Partlow Temperature Saginomiya Temperature Electronic Partlow Temperature Temperature Recorder -- Compressor Mounting, Guards, Crankcase Heater and Drain Line Heater Compressor Gauges and Cable Restraint Components (Bungy Cords and J--Hooks) Voltage Cables (460V and 230V) Rev ETABLE OF CONTENTS (Continued)

3 Autotransformer (With and Without CB2 and Transformer Bridge Unit) Labels and INTERROGATOR AND Interrogator COMPRESSOR -- MOTOR Service Replacement Terminal Mounting and Junction Box Service Valve Compressor -- Motor Body Pump End Crankshaft, Rod and Piston Valve Plate Gasket Controller/DataCorder NUMBER INDEXI ndex Rev EiiiINTRODUCTION1 INTRODUCTIONThe Carrier Transicold model 69nt40 --511--300 seriesunits are of lightweight aluminum frame construction,designed to fit in the front of a container and serve as thecontainer front CONFIGURATION IDENTIFICATIONUnit identification information is provided on a platelocated near the compressor. The plate provides the unitmodel number, the unit serial number and the unit partsidentification number (PID).

4 The model numberidentifies the overall unit configuration while the PIDprovides information on specific optional equipment,factory provision to allow for field installation ofoptional equipment and differences in detailed identification for the Models coveredherein are provided in the Carrier Transicold ContainerUnit Matrix manual, publication T--300. Printed copiesof the T--300 may be obtained from Carrier , aweekly updated copy may befoundat theCarrierWeb site, OPTION DESCRIPTIONSV arious options may be factory or field fitted to the baseunit. These options are listed in the tables and describedin the following BatteryThe refrigeration controller may be fitted with standardreplaceable batteries or rechargeable battery DehumidificationThe unit may be fitted with a humidity sensor.

5 Thissensor allows setting of a humidity set point in thecontroller. In the dehumidification mode the controllerwill operate to reduce internal container moisture Control BoxThe control box may be of aluminum or compositematerial and each type box may be fittedwith Temperature ReadoutThe unit may be fitted with suction and dischargetemperature sensors. The sensor readings may beviewed on the controller Pressure ReadoutThe unit may be fitted with suction and dischargepressure gauges or suction and discharge transducers orno pressure readout. The transducer readings may beviewed on the controller USDAThe unit may be supplied with fittings for additionaltemperature probes which allow recording of USDACold Treatment data by the integral DataCORDER function of the Micro--Link refrigeration InterrogatorUnits that usetheDataCORDER functionarefittedwithinterrogator receptacles for connection of equipment todownload the recorded data.

6 Two receptacles may befitted, oneaccessible from the front of the container andthe other mounted inside the container (with the USDA receptacles). Remote MonitoringThe unit may be fitted with a remote monitoringreceptacle. This item allows connection of remoteindicators for COOL, DEFROST and IN otherwise indicated, the receptacleis mounted atthe control box unit may be fitted with a communications interfacemodule. The communications interface module is aslave module which allows communication with amaster central monitoring station. The module willrespond to communication and return information overthe main power line. Refer to the ship master systemtechnical manual for further CompressorThe unit is fitted with a single speed Condenser CoilThe unit may be fitted with a 2 row or 4 row coil usingnominal 3/8 inch tubing, or the unit may be fitted with a3 row coil using 7mm tubing.

7 The required refrigerantcharge is different for each AutotransformerAn autotransformer may be provided to allow operationon 190/230, 3phase, 50/60 hertz power. Theautotransformer raises the supply voltage to thenominal 380/460 volt power required by the base autotransformer may also be fitted with anindividual circuit breaker for the 230 volt the unit is fitted with an autotransformer andcommunications module, the autotransformer will befitted with a transformer bridge unit (TBU) to assist Temperature RecorderOne of three temperature recording devices may befitted to the unit. The devices include a mechanicalrecorder manufactured by Partlow Corporation, amechanical recorder manufactured by SaginomiyaCorporation, and an electronic recorder manufacturedby Partlow GuttersRain gutters may be fitted over the control box andrecorder section to divert rain away form the different gutters include standard length boltedgutters, extended length gutters and riveted Rev HandlesTheunit maybefittedwithhandles tofacilitateaccesstostacked containers.

8 These handles may included fixedhandles (located at the sides of the unit) and/or a hingedhandle at the center (attached to the condenser coilcover). Thermometer PortTheunit maybefittedwithports inthefront oftheframefor insertion of a thermometer to measure supply and/orreturn air temperature. If fitted, the port(s) will require acap and Water CoolingThe refrigeration system may be fitted with a watercooled condenser. The condenser is constructed usingcopper--nickel tube for sea water applications. Thewater cooled condenser is in series with the air cooledcondenser replaces the standard unit receiver. Whenoperating on the water cooled condenser, the condenserfan is deactivated by either a water pressure switch orcondenser fan Back PanelsBack panel designs that may be fitted include panels ofaluminum and stainless steel.

9 Panels may be fitted withaccess doors and/or hinge 460 Volt CableVarious power cable and plug designs are available forthe main 460 volt supply. The plug options tailor thecables to each customers 230 Volt CableUnits equipped with an autotransformer require anadditional power cable for connection to the 230 voltsource. Various power cable and plug designs areavailable. The plug options tailor the cables to eachcustomers Cable RestraintVarious designs are available for storage of the powercables. These options are variations of the compressorsection front Upper Air (Fresh Air Make Up)The unit may be fitted with an upper fresh air makeupassembly. These assemblies are supplied in twodesigns, the standard design and the micro design.

10 Theopenings may also be fitted with Lower Air (Fresh Air Make Up)The unit may be fitted with a lower fresh air makeupassembly. These assemblies are supplied in twodesigns, the standard design and the macro design. Theopenings may also be fitted with Controlled AtmosphereThe units may be fitted with the TransFresh information on the TransFresh system, contactTransFresh Corporation, Box 1788, Salinas Arctic ModeTo improve operation in cold ambients, the unit may befitted with a crankcase heater and/or a condensate drainline heater. The crankcase heater is operated, beforestart--up, to warm the compressor oil and boil off anyliquid refrigerant that may be present in the drain line heater is operated to prevent freezing ofthe evaporator condensate drain HumidificationThe unit may be equipped with the Carrier TransicoldNatureFreshhumiditymanagement system.