INSTALLATIONINSTRUCTIONSLire et comprendre ce manuel avant de proc der l' INSTALLATION , des r -glages, de l'entretien ou des r parations. L' INSTALLATION de cet appareil doit tre effectu e par un r parateur qualifi . Toute modification de cet appareil peut tre extr mement dangereuse et entra ner des blessures ou dommages mat series DUO-THERM HP530 series DUO-THERM HP HEAT PUMP579 series BRISk AIR590 series BRISk AIR591 series HEAT PUMP595 series quick COOL600 series PENgUIN630 series PENgUINRoof Top Air Conditioners & Heat PumpsUsed With Part No. & Control Center Electronic Control kit Ducted INSTALLATION (White) Comfort Control CenterTM (Black) Comfort Control CenterTMTHIS UNIT IS DESIgNED FOR OEM INSTALLATIONALL INITIAL INSTALLATIONS MUST BE APPROVED BYDOMETIC CORPORTIONREVISIONForm No.

520 Series DUO-THERM HP 530 Series DUO-THERM HP HEAT PUMP 579 Series BRISK AIR 590 Series BRISK AIR 591 Series HEAT PUMP 595 Series QUICK COOL 600 Series PENGUIN 630 Series PENGUIN Roof Top Air Conditioners & Heat Pumps Used With Part No. 3109226.005 & 3109407.001 Comfort Control Center Electronic Control Kit Ducted Installation …

Tags:

  Series, Quick, Skrbi, Series brisk air, 595 series quick

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of MODELS INSTALLATION INSTRUCTIONS

1 INSTALLATIONINSTRUCTIONSLire et comprendre ce manuel avant de proc der l' INSTALLATION , des r -glages, de l'entretien ou des r parations. L' INSTALLATION de cet appareil doit tre effectu e par un r parateur qualifi . Toute modification de cet appareil peut tre extr mement dangereuse et entra ner des blessures ou dommages mat series DUO-THERM HP530 series DUO-THERM HP HEAT PUMP579 series BRISk AIR590 series BRISk AIR591 series HEAT PUMP595 series quick COOL600 series PENgUIN630 series PENgUINRoof Top Air Conditioners & Heat PumpsUsed With Part No. & Control Center Electronic Control kit Ducted INSTALLATION (White) Comfort Control CenterTM (Black) Comfort Control CenterTMTHIS UNIT IS DESIgNED FOR OEM INSTALLATIONALL INITIAL INSTALLATIONS MUST BE APPROVED BYDOMETIC CORPORTIONREVISIONForm No.

2 8/07(Replaces )(French ) 2007 Dometic CorporationLaGrange, IN 46761 This manual must be read and un-derstood before INSTALLATION , ad-justment, service, or maintenance is performed. This unit must be installed by a qualified service technician. Modification of this product can be extremely hazard-ous and could result in personal injury or property OFFICED ometic Corporation2320 Industrial ParkwayElkhart, IN 46516574-294-2511 CANADAD ometic Corporation46, Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA519-720-9578 For Service CenterAssistance Call:800-544-4881 RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE:Model NumberSerial NumberDate PurchasedImportant: These INSTRUCTIONS muststay with unit.

3 Owner read from manuals search engine 2 CCC Ducted INSTALLATION INSTRUCTIONS 1. gENERAL INFORMATIONA. Product features or specifications as described or il-lustrated are subject to change without This air conditioner is designed for:1. INSTALLATION on a recreational vehicle at the time the vehicle is Mounting on the roof of a recreational Connection to an air distribution system located in the ceiling/roof cavity of the recreational Roof construction with rafters/joists on minimum of 16 inch Minimum of " and maximum of " distance between roof to ceiling of recreational vehicle. Alternate INSTALLATION methods will allow for roofs more than " The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the RV.

4 Some preventative measures taken by the occupants of the RV can reduce the heat gain and improve the performance of the air conditioner. During extremely high outdoor temperatures, the heat gain of the vehicle may be reduced by:1. Parking the RV in a shaded Using window shades (blinds and/or curtains).3. Keeping windows and doors shut or minimizing Avoiding the use of heat producing on High Fan/Cooling mode will give optimum or maximum efficiency in high humidity or high outside temperatures. Starting the air conditioner early in the morning and giving it a "head start" on the expected high outdoor ambient will greatly improve its ability to maintain the desired indoor temperature.

5 For a more permanent solution to high heat gain, accesso-ries like A&E outdoor patio and window awnings will reduce heat gain by removing the direct sun. They also add a nice area to enjoy company during the cool of the evening. D. CondensationNote: The manufacturer of this air conditioner will not be responsible for damage caused by condensed moisture on ceilings or other surfaces. Air contains moisture and this moisture tends to condense on cold surfaces. When air enters the RV, condensed moisture may appear on the ceiling, windows, metal parts, etc. The air conditioner re-moves this moisture from the air during normal operation.

6 Keeping doors and windows closed when this air condi-tioner is in operation will minimize condensed moisture on cold surfaces. SAFETY INSTRUCTIONSThis manual has safety information and instruc-tions to help users eliminate or reduce the risk of accidents and SAFETY INFORMATIONThis is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal recommended precautions and safe op-erating SIgNAL WORDSA signal word , WARNINg OR CAUTION is used with the safety-alert symbol. They give the level of risk for potential injury. indicates a potentially hazard-ous situation which, if not avoided, could result in death or serious injury.

7 Indicates a potentially hazard-ous situation which, if not avoided may result in minor or moderate injury. used without the safety alert symbol indicates, a potentially hazardous situ-ation which, if not avoided may result in property and follow all safety information and from manuals search engine 3 CCC Ducted INSTALLATION INSTRUCTIONS MODEL NOMINAL ELECTRICAL COMPRESSOR COMPRESSOR FAN MOTOR FAN MOTOR SCFM-HIGH TOTAL REFRIGERANT MINIMUM AC CIRCUIT INSTALLED MINIMUMNO. CAPACITY RATING RATED LOAD LOCKED RATED LOAD LOCKED SPEED STATIC R-22 (OZ) WIRE SIZE* PROTECTION WEIGHT GENERATOR (BTU/HR) AMPS ROTOR AMPS ROTOR MAX/MIN MAX/MIN ** USER (POUNDS) SIZE** COOLING AMPS AMPS W.

8 C. SUPPLIED 1 UNIT/ 2 7,180 325 / 250 / 20 Amp 75 KW / 7,100 325 / 250 / 20 Amp 75 KW / 11,000 325 / 250 / 20 Amp 94 KW / 11,000 325 / 250 / 20 Amp 94 KW / 11,000 325 / 250 / 20 Amp 94 KW / 11,000 325 / 250 / 20 Amp 94 KW / 11,000 325 / 250 / 20 Amp 94 KW / 11,000 325 / 250 / 20 Amp 94 KW / 13,500 325 / 250 / 20 Amp 104 KW / 13,500 325 / 250 / 20 Amp 104 KW / 13,500 325 / 250 / 20 Amp 100 KW / 13,500 325 / 250 / 20 Amp 104 KW / 13,500 325 / 250 / 20 Amp 100 KW / 13,500 325 / 250 / 20 Amp 100 KW / 13,500 325 / 250 / 20 Amp 94 KW / 13,500 325 / 250 / 20 Amp 94 KW / 13,500 325 / 250 / 20 Amp 94 KW / 13,500 325 / 250 / 20 Amp 94 KW / KW 13,500 325 / 250 / 20 Amp 94 KW / KW 13,500 325 / 250 / 20 Amp 94 KW / KW 13,500 325 / 250 / 20 Amp 94 KW / KW 13.

9 500 325 / 250 / 20 Amp 94 KW / KW 13,500 325 / 250 / 20 Amp 94 KW / KW 13,500 325 / 250 / 20 Amp 94 KW / 13,500 325 / 250 / 20 Amp 94 KW / 13,500 325 / / 20 Amp 94 KW / 15,000 350 / 250 0 20 Amp 101 KW / 15,000 350 / 250 / 20 Amp 104 KW / 15,000 350 / 250 / 20 Amp 104 KW / 15,000 350 / 250 / 20 Amp 101 KW / 15,000 325 / 250 / 20 Amp 102 KW / 15,000 325 / 250 .040 / 20 Amp 102 KW / KWSPECIFICATIONS115 VAC,60 HZ.

10 , AWGC opperup to 24 * For wire lengths over 24 ft. consult the National Electric Code for proper sizing.** Dometic Corporation gives gENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual appli cations When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high altitudes and from lack of maintenance.** CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers from manuals search engine 4 CCC Ducted INSTALLATION INSTRUCTIONS MODEL NOMINAL ELECTRICAL COMPRESSOR COMPRESSOR FAN MOTOR FAN MOTOR SCFM-HIGH TOTAL REFRIGERANT MINIMUM AC CIRCUIT INSTALLED MINIMUMNO.