Nonmetallic Conduit Junction BoxesMolded Nonmetallic Junction Boxes6P RatedIt s another first from Carlon - the first Nonmetallic Junction Boxes UL Listed with a NEMA 6P rating perSection , Exception of the National Electrical from PVC or PPO thermoplastic moldingcompound and featuring foam-in-place gasketed lidsattached with stainless steel screws, these rugged enclosures offer all the corrosion resistance and physicalproperties you need for direct burial 6P enclosures are intended for indoor or outdooruse, primarily to provide a degree of protection againstcontact with enclosed equipment, falling dirt, hose-directed water, entry of water during prolonged submersion at a limited depth, and external ice formation. All Carlon Junction Boxes are UL Listed and maintain a minimum of a NEMA Type4/4x Rating. Parts numbers with an asterisk (*) are UL Listed andmaintain a NEMA Type 6 PRating and Type 4/4X where notedby Size x W x (Lbs.)

180 www.carlon.com Rigid Nonmetallic Conduit – Junction Boxes Molded Nonmetallic Junction Boxes 6P Rated It’s another first from Carlon® - the first nonmetallic junction boxes UL Listed with a NEMA 6P rating per

Tags:

  Trade, Nonmetallic, Boxes, Molded, Molded nonmetallic junction boxes 6p rated, Junction

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Molded Nonmetallic Junction Boxes 6P Rated by

1 Nonmetallic Conduit Junction BoxesMolded Nonmetallic Junction Boxes6P RatedIt s another first from Carlon - the first Nonmetallic Junction Boxes UL Listed with a NEMA 6P rating perSection , Exception of the National Electrical from PVC or PPO thermoplastic moldingcompound and featuring foam-in-place gasketed lidsattached with stainless steel screws, these rugged enclosures offer all the corrosion resistance and physicalproperties you need for direct burial 6P enclosures are intended for indoor or outdooruse, primarily to provide a degree of protection againstcontact with enclosed equipment, falling dirt, hose-directed water, entry of water during prolonged submersion at a limited depth, and external ice formation. All Carlon Junction Boxes are UL Listed and maintain a minimum of a NEMA Type4/4x Rating. Parts numbers with an asterisk (*) are UL Listed andmaintain a NEMA Type 6 PRating and Type 4/4X where notedby Size x W x (Lbs.)

2 E989 NNJ -CAR*4 x 4 x 25311/1635/8 *4 x 4 x 45311/1631/2 E989 NNR-CAR*4 x 4 x 64311/1633/8 *5 x 5 x 24411/1641/2 *6 x 6 x 42655/8 *6 x 6 x 6855/853/8 x 8 x 4188 x 8 x 72721/3275/16 x 12 x 43115/8111/2111 x 12 x 621115/16117/8117 Automation (877) 268-3700 Nonmetallic Conduit Technical InformationCorrosion Resistance of Carlon Schedule 40 and Schedule 80 PVC Conduit and FittingsCarlon Schedule 40 and Schedule 80 are generally acceptable for use in environments containing the chemicalsbelow. These environmental resistance ratings are basedupon tests where the specimens were placed in completesubmergence in the reagent listed. Schedule 40 andSchedule 80 can be used in many process areas wherechemicals not on this list are manufactured or used becauseworker safety requirements dictate that any air presence orsplashing be at a very low there are any questions for specific suitability in agiven environment.

3 Prototype samples should be tested under actual Acid O-20%Acetic Acid 20-30%Acetic Acid 3O-60%Acetic Acid 80%Acetic Acid GlacialAcetic Acid VaporsAcetyleneAdipic AcidAlumAluminum ChlorideAluminum FluorideAluminum HydroxideAluminum OxychlorideAluminum NitrateAluminum SulfateAmmonia-Dry GasAmmonium BifluorideAmmonium CarbonateAmmonium ChlorideAmmonium Hydroxide 28%Ammonium MetaphosphateAmmonium NitrateAmmonium PersulfateAmmonium Phosphate NeutralAmmonium SulfateAmmonium SulfideAmmonium ThiocyanateAmyl AlcoholAnthraquinoneAnthraquinonesulfoni c AcidAntimony TrichlorideAqua RegiaArsenic Acid 80%Arylsulfonic AcidBarium CarbonateBarium ChlorideBarium HydroxideBarium SulfateBarium SulfideBeet Sugar LiquorBenzine Sulfonic Acid 10%Benzoic AcidBismuth CarbonateBlack Liquor (Paper Industry)Bleach Active CL2 BoraxBoric AcidBrineBreeder Pellets Dane. FishBromic AcidBromine WaterButaneButadieneButyl AlcoholButyl PhenolButyleneButyric AcidCalcium BisulfiteCalcium CarbonateCalcium ChlorateCalcium ChlorideCalcium HydroxideCalcium HypochloriteCalcium NitrateCalcium SulfateCarbonic AcidCarbon Dioxide Gas WetCarbon Dioxide AqueousSolutionCarbon MonoxideCaustic PotashCaustic SodaChloracatic AcidChloral HydrateChlorine Gas (Dry)Chlorine Gas (Moist)

4 Chlorine WaterChlorosulfonic AcidChrome AlumChromic Acid 10%Chromic Acid 30%Chromic Acid 40%Chromic Acid 50%Citric AcidCopper ChlorideCopper CyanideCopper FluorideCopper NitrateCopper SulfateCottonseed OilCresylic Acid 50%Crude Oil SourCrude Oil SweetDemineralized WaterDextrinDextroseDiglycolic AcidDisodium PhosphateEthyl AlcoholEthylene GlycolFatty AcidsFerric ChlorideFerric NitrateFerric SulfateFerrous ChlorideFerrous SulfateFluorine Gas WetFluorine Gas DryFluoroboric AcidFluorosilicic AcidFormaldehydeFormic AcidFructoseGallic AcidGas Coke OvenGas Natural (Dry)Gas Natural (Wet)Gasoline SourGasoline RefinedGlucoseGlycerine (Glycerol)GlycolGlycolic AcidGreen Liquor (Paper Industry)HeptaneHexanol, TertiaryHydrobromic Acid 20%Hydrochloric Acid 0% - 25%Hydrochloric Acid 25% - 40%Hydrocyanic Acid or Hydrogen CyanideHydrofluoric Acid 10%Hydrofluorosilicic AcidHydrogen PhosphideHydrogen Sulfide DryHydrogen Sulfide Aqueous SolutionHydroquinoneHydroxylamine SulfateIodineKeroseneLactic Acid 28%Lauric AcidLauryl ChlorideLauryl SulfateLead AcetateLime SulfurLinoleic AcidLinseed OilLubricating OilsMagnesium CarbonateMagnesium ChlorideMagnesium HydroxideMagnesium NitrateMagnesium SulfateMaleic AcidMalic AcidMercuric ChlorideMercuric CyanideMercurous NitrateMercuryMethyl SulfateMethylene ChlorideMineral OilsNaphthaleneNickel ChlorideNickel NitrateNitric Acid, AnydrousNitric Acid 20%Nitric Acid 40%Nitric Acid 60%NitrobenzeneNitrous OxideOils and FatsOils Petroleum (See Type)

5 Oleic AcidOxalic AcidPalmitic Acid 10%Perchloric Acid 10%Phenylhydrazine HydrochloridePhosgene, GasPhosphoric Acid 0-25%Phosphoric Acid 25-50%Phosphoric Acid 50-85%Photographic ChemicalsPlating SolutionsPotassium BicarbonatePotassium BichromatePotassium BoratePotassium BromidePotassium CarbonatePotassium ChloridePotassium ChromatePotassium CyanidePotassium DichromatePotassium FerricyanidePotassium FerrocyanidePotassium FluoridePotassium HydroxidePotassium NitratePotassium PerboratePotassium PerchloritePotassium Permanganate 10%Potassium PersulfatePotassium SulfatePropanePropyl AlcoholSilicic AcidSilver CyanideSilver NitrateSilver Plating SolutionsSodium AcetateSodium ArseniteSodium BenzoateSodium BicarbonateSodium BisulfateSodium BisulfiteSodium BromideSodium ChlorateSodium ChlorideSodium CyanideSodium DichromateSodium FerricyanideSodium FerrocyanideSodium FluorideSodium HydroxideSodium HypochloriteSodium NitrateSodium NitriteSodium SulfateSodium SulfideSodium SulfiteSodium Thiosulfate (Hypo)

6 Stannic ChlorideStannous ChlorideStearic AcidSulfurSulfur Dioxide Gas DrySulfur TrioxideSulfuric Acid 0-10%Sulfuric Acid 10-75%Sulfuric Acid 75-90%Sulfurous AcidTannic AcidTanning LiquorsTartaric AcidTitanium TetrachlorideTriethanolamineTrimethyl PropaneTrisodium PhosphateTurpentineUreaVinegarWhiskeyWhi te Liquor (Paper Industry)WinesZinc ChlorideZinc ChromateZinc CyanideZinc NitrateZinc SulfateGross Automation (877) 268-3700 Nonmetallic Conduit Specification Carlon rigid Nonmetallic conduit system shall be installed as indicated on the drawings and as specified wiring shall be installed in Carlon rigid Nonmetallic conduit shall be secured by means of proper fittings shall be outlet Boxes , fittings and Junction Boxes shall be usedfor all outlets,pull Boxes and Junction points. (Lighting fixturesshall not be supported or hung from PVC Junction Boxes but besupported in position by other means.)

7 Conduits shall be mounted securely by suitable hangers or straps with the maximum spacing of points of supports not greater than indicated by Section of where embedded in concrete or direct buried, Carlonconduit shall be supported to permit adequate lineal movement to allow for expansion and contraction of conduitdue to temperature aboveground installations where temperature change inexcess of 14 C (25 F) is anticipated, expansion joints shall be Table (A) NEC for expansion care shall be taken when field bending is employed to maintain the internal diameter and wall thickness of Format forSpecifying Carlon NonmetallicConduit, Conduit Fittings andJunction BoxesGross Automation (877) 268-3700