Transcription of MS + SUPER tech
1 Mr .steam . _____ Technical Specifications 11/4" (32). Model MSSuper1E-3E. 183/4". Serial Number 900000 and higher (476). Water Inlet Standard Features Control & Acces- sory Connections 151/2". Stainless steel tank Steam Outlet (394). Industrial, large diameter, serviceable heating Safety Valve element Manual Drain Valve 97/8". Modular Plug and Play connections (251). Optional Electronic water-level control system AutoFlush 71/4". (184). Full-port drain valve 2". 21/2" 21/4". Limited lifetime steam generator parts warranty (64) 63/8". (51). (57). Safety Features 17" (162). (432) 47/8". (124). 6". Built-in, low-voltage 24-volt control 60-minute electronic countdown Electrical (152). 77/8". ASME safety valve shutdown with 75-minute limiting (200). safety back-up All electrical wiring to be installed by a qualified licensed Locating and Installing the Steam Generator Unit electrician in accordance with National Electrical Code and local electrical code.
2 Select a location as near as practical to or chemicals or in areas having a high the steam room, within 60 feet. Typical concentration of chlorine. Power Wiring locations include: closet, van-ity Install steambath generator on a solid 1. Check power voltage. Use 240V rated unit when cabinet, heated attic or basement. and level surface or securely mounted to supply matches rating of unit before installation. Do not install steambath generator in- a wall using the keyhole slots provided. 2. Use minimum 90 C/300V rated insulated copper side the steam room. conductors only, type THHN or equal sized in Install steambath generator in an upright Do not install steambath generator position only. accordance with National Electrical Code and local outdoors or wherever environmental Provide a minimum of 12 inches inches at electrical code for the Amps in Ampere Chart. conditions may affect the safety and/or both ends and top of the steam If allowed by code, NM cable may require a larger performance of the generator.
3 Generator or as required for servicing. wire size than as listed on the chart. Do not install steambath generator or Alternately provide unions to facilitate 3. Connect suitably sized equipment grounding wire to plumbing lines in unheated attic or any installation and disconnection of the ground terminal provided. locations where water could freeze. steam generator. 4. Install a separate circuit breaker between supply and Do not install steambath generator The minimum clearance from com- unit. Provide a power supply disconnect within sight near flammable or corrosive materials bustible surfaces is zero all around. of the steam generator or one that is capable of Required Plumbing being locked in the open position. Steam Outlet (1/2" NPT) Safety Valve (3/4" NPT) Drain (1/2" NPT). Water Supply (3/8" NPT) Steam Head (1/2" NPT) AMPERE CHART. MODEL Vol Wire Size FOR ILLUSTRATIVE PURPOSES ONLY.
4 IMPORTANT NOTE: FOR SAFE NO. (CU. FT.) KW Volts Phase Amps (AWG) for 25oC. AND TROUBLE FREE INSTALLATION visit before installation 1 49 6. to download the Installation, Operation and Maintenance Manual or refer to 208. the manual provided with the unit. 3 28 8. MSSUPER1E 339 10. MODEL VOLTAGE* PHASE OPTIONS 1 42 8. 240. 3 24 8. MSSUPER1E B=208 I1-Single Phase I Express Date: 1 58 6. MSSUPER2E C=240 I 3-Three Phase Steam Submitted by: 208. 3 34 8. MSSUPER3E *Contact Mr. Steam for other voltages MSSUPER2E 411 12. 1 50 6. Location: 240. 3 29 8. Architect: 1 73 4. 208. Engineer: 3 42 8. MSSUPER3E 482 15. Contractor: 1 63 4. 240. Notes: 3 36 8. Required Equipment: iSteam3, AirTempo, Optional Equipment: iGenie, AudioWizard, ChromaSteam, HomeWizard, Recessed iTempo, iTempoPlus Controls Light, MS Light, MS Wallseat, AutoFlush, Condensation Pan, AromaSteam Sussman-Automatic Corp 43-20 34th Street, Long Island City, NY 11101 TEL: 800 76 STEAM / 9410 S.
5 La Cienega Blvd. Inglewood CA 90301 TEL: 800 72 STEAM TS0041-S1E-S3E REV