Example: marketing

N95 Particulate Filters P2 Particulate Filters - …

All moldex P2 respirators and Filters also meet the requirements of the NIOSH N95 moldex Healthcare respirators are US FDA (Federal Drug Administration) 510K compliant (Class 2 medical device) and are also cleared by the Australian TGA (Therapeutic Goods Administration) as a Class 1 medical device. They are NIOSH certified as N95, and are P2 are slight differences in the testing requirements (as outlined below) between P2 and N95 respirators and Filters but these differences have only slight impact on the level of respiratory protection provided to the user. P2 Particulate FiltersN95 Particulate Filters Classification - United States National Institute of Occupational Safety and Health (NIOSH) Must have a filter efficiency of at least 95% when tested with Sodium Chloride aerosol Aerosol particle size has a mass median diameter of approximately microns

All Moldex P2 respirators and filters also meet the requirements of the NIOSH N95 specification. All Moldex Healthcare respirators are US FDA (Federal Drug Administration) 510K compliant (Class 2

Tags:

  Filter, Particulates, N95 particulate filters p2 particulate filters, Moldex p2, Moldex

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of N95 Particulate Filters P2 Particulate Filters - …

1 All moldex P2 respirators and Filters also meet the requirements of the NIOSH N95 moldex Healthcare respirators are US FDA (Federal Drug Administration) 510K compliant (Class 2 medical device) and are also cleared by the Australian TGA (Therapeutic Goods Administration) as a Class 1 medical device. They are NIOSH certified as N95, and are P2 are slight differences in the testing requirements (as outlined below) between P2 and N95 respirators and Filters but these differences have only slight impact on the level of respiratory protection provided to the user. P2 Particulate FiltersN95 Particulate Filters Classification - United States National Institute of Occupational Safety and Health (NIOSH) Must have a filter efficiency of at least 95% when tested with Sodium Chloride aerosol Aerosol particle size has a mass median diameter of approximately microns.

2 This aerosol is delivered to the filter at a flow rate of 85 liters/minute N95 respirators may only be used for protection against oil-free aerosols Classification - Australian/New Zealand Standard AS/NZS 1716 Respiratory Protective Devices Must have a filter efficiency of at least 94% when tested with Sodium Chloride aerosol Aerosol particle size has a mass median diameter of to microns with a range of particles in the to 2 micron size range. This aerosol is delivered to the filter at a flow rate of 95 liters/minuteMOLDEX-METRIC, INC. 10111 W. Jefferson Blvd.

3 , Culver City, CA 90232 Tel: +1 (800) 421-0668 or +1 (310) 837-6500 Fax: +1 (310) 837-9563 Email: Technical Service Department: +1 (800) 421-0668 or +1 (310) 837-6500 Ext. 512/550 moldex and Ideas that wear well are registered trademarks. The PVC-Free logo is a trademark of moldex -Metric, Inc. Made in moldex -METRIC, 30/14-16 Stanton Road, Seven Hills, NSW 2147 TEL +61 (2) 9838 7588 FAX +61 (2) 9838 7544 Email: ZEALAND moldex -METRIC, Spence Road, Henderson, Auckland, NZTEL +64 (9) 837 8247 FAX +64 (9) 837 8248 Email: P2 and N95 Respirators and 16/26/12 2:46 PM