Transcription of 抵抗溶接用 - nadex-p.jp
1 For resistance weldingAir Cooling Resistance Welding Controller Effective use of spaceAble to set the welding controller on the robot controller Reduction of troublesNot using water for cooling, we do not have to worry the troubles due to the stock of scale in the tube, the failure of running water or etc. Water CoolingACInverterFAN FAN FAN AC Duty200A10%300A10%300A10%400A10% Air CoolingInverter Type Figure, showing the duty of each type of the timer controller C 1 Duty and Primary Current01002003004005005 6 7 8 9 101112131415 Duty (%) Primary Current (A) 1 2 FAN A A UP Cooling FANAble to install FAN for force cooling, at maximum one inside and two outside. Each FAN rises the usage rate about 50A of Duty AC Welding ControllerInverter Welding Controller RatingRated Voltage A A Duty300A 10%(without FAN) 300A 10%(without FAN) Rated Power Frequency EnvironmentTemperature and Humidity ( )IGBT( )
2 Power UnitMain Circuit ElementIsolatecd ThyristorIsolated IGBT Cool Specifications Enclosure and Power Unit I/OInterfaceInput/Output IGBT PWM Current ControlControl MethodBridge type PWM control by IGBT 700Hz 1,800 HzInverter frequency 700Hz 1,800Hz Constant Current Regulation Voltage Compensation Control Control RangeSecondary Current Turn Ratio FunctionWeld Schedule Stepper Function Low Current Detection Level Setting Function Over Current Detection Level Setting Function Stepper method (OFF, Step up, Linear up) Number of step 10 steps(0 9 step) Synchoronous phase control using the thyristor DeviceNet/CC-Link/ProfiBus/DIO*1 FAN Natural air cooling (Forced air cooling with FAN)-5 +45 C / / Less than 90%(Without dewing)50Hz/60Hz Automatic selection1 380/400/415/440/460/480V 15%*13 380/400/415/440/460/480V 15%*1 Specification Outside Dimension 4 Optional Function Option Teaching Box Reset Box (1m 40m)
3 Reset Cable The Wiring for the Voltage Detection WinTB2 2 Pressure Control Function 3 Short Detect Function 3 Deposition Function Primary Cable Detection FunctionEtherNet Management Function by Ethernet CC-Link Interface CC-Link ProfiBus Interface ProfiBus 2 DIO 3 4 *1 Select either one*2 Select only with DIO*3 Select either one*4 Those show the outside dimensions - AC type without a breaker box and inverter type with a breaker box. AC type210400430 Front Side Inverter type600510400 Front Side Without Breaker With Breaker 460-8338 9 27 TEL:052-323-2215 FAX:052-322-3059 481-0038 TEL:0568-21-1428 FAX:0568-23-5540 330-0802 1-114-1(ORE 8F)TEL:048-650-7181 FAX:048-650-7182 532-0011 3-9-12( )TEL:06-6305-0525 FAX:06-6305-5556