Example: stock market

Neo-Ray Covera Spec Sheet - Electrical Sector

DESCRIPTIONC atalog #ProjectCommentsPrepared byTypeDateSPECIFICATION FEATURES08/28/ 2017 Specifications and dimensions subject to change without additional information on the following INFORMATIONS ample Number: S930 DIP-W235-PT4-UDD-WPS524039EN1 of 4 Neo-RaySee page 4 for Technical NotesSeriesOpticsLight Level (nominal Lms) 5 CCTC eiling TypeLength 6S930 DIP = Covera Direct / Indirect PendantW = Wavestream 40% Up 60% Down1 = Light Level 1 [ lms (2ft), lms (4ft)] 12 = Light Level 2 [ lms (2ft), lms (4ft)] 13 = Light Level 3 [ lms (2ft), lms (4ft)] 14 = Light Level 4 [ lms (2ft), lms (4ft)] 15 = Light Level 5 [ lms (2ft), lms (4ft)] 127 = 2700K (90 CRI)30 = 3000K (85 CRI)35 = 3500K (85 CRI)40 = 4000K (85 CRI)GD = On-Grid (includes teg)PT = Pierced Tile GridSF = Sheet Rock Flush (Mud Flange)

DESCRIPTION Catalog # Project Comments Prepared by Type Date SPECIFICATION FEATURES 08/28/2017 Specifications and dimensions subject to change without notice.

Tags:

  Date, 2017, Sheet, Spec, Vocera, Neo ray covera spec sheet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Neo-Ray Covera Spec Sheet - Electrical Sector

1 DESCRIPTIONC atalog #ProjectCommentsPrepared byTypeDateSPECIFICATION FEATURES08/28/ 2017 Specifications and dimensions subject to change without additional information on the following INFORMATIONS ample Number: S930 DIP-W235-PT4-UDD-WPS524039EN1 of 4 Neo-RaySee page 4 for Technical NotesSeriesOpticsLight Level (nominal Lms) 5 CCTC eiling TypeLength 6S930 DIP = Covera Direct / Indirect PendantW = Wavestream 40% Up 60% Down1 = Light Level 1 [ lms (2ft), lms (4ft)] 12 = Light Level 2 [ lms (2ft), lms (4ft)] 13 = Light Level 3 [ lms (2ft), lms (4ft)] 14 = Light Level 4 [ lms (2ft), lms (4ft)] 15 = Light Level 5 [ lms (2ft), lms (4ft)] 127 = 2700K (90 CRI)30 = 3000K (85 CRI)35 = 3500K (85 CRI)40 = 4000K (85 CRI)GD = On-Grid (includes teg)PT = Pierced Tile GridSF = Sheet Rock Flush (Mud Flange)

2 SR = Sheet Rock with proud cover plateST = Structure Mount 2 = 2 Individual4 = 4 IndividualVoltageDriver OptionsFinish 13 Integral Emergency 8 Options 8U = Universal 120-277 VAC1 = 120 VAC2 = 277 VAC 3 = 347 VAC 348 = 48 VDC 4DD = Standard 0-10V (10%-100%)HCD = 0-10V (1%-100%) 1, 8 DCD = 0-10V (.1%-100%) 1, 85 LT = Fifth Light DALI (10%-100%)1, 85 LTHD = Fifth Light DALI (.1%-100%) 1, 8 STP = Step Dim 1, 8 LUE = A-Series w/ eco sys 1, 8 LUL = A-Series w/ 3W dim 1, 8L5 = 5 Series 1, 8LH = H Series 1, 8DD3 = 347V 0-10 (5%-100%) 1, 3, 8LV 1 = DLVP Driver 1, 4, 8W = White Powder CoatS = Silver Powder CoatB = Black Powder CoatC = Custom Color 8H1 = White Oak Hydrographic 8, 9H2 = Grey Ash Hydrographic 8, 9H3 = Dark Walnut Hydrographic 8, 9H4 = Brown Willow Hydrographic 8, 9H5 = White Marble Hydrographic 8, 9H6 = Carbon Fiber Hydrographic 8, 9HC = Custom Hydrographic 8, 9EL7W = Integral Battery Pack 2EL14W = Integral Battery Pack 2 GTD2 = Generator Transfer Device 2CP = Chicago plenumLWTPD1 = Tilemount Lumawatt Pro Wireless Sensor 7cULus 1598IC RatedDamp Location ListedLM79/LM80 CompliantROHS Compliant metal housing.

3 Nominal 2 and 4 individual fixture lengths. All components are RoHs optical grade acrylic embeddedwith patented WaveStreamAccu-Aim optics for optimaldistribution, excellent uniformity,and high performance. Light engine becomes virtually clear inthe housing trims are finished with an electrostatically applied polyester powder coat paint for long lasting durability. Optional architectural hydrographic finishes are also , Pierced-Tile, Surface, Sheetrock and Flangless LED system powered by aremote driver through low-voltage aircraft cable to deliver optimal performance. LED s are available in 2700K (90 CRI), 3000K, 3500K or 4000K with a typical CRI 85. Projected life is 452k hours at 70% lumen output for the majority of configurations.

4 Electronic drivers are available for 120-277V and 347V applications. ControlsEquipped standard with a 0-10V continuous dimming driver compatible with most standard dimming devices (refer to website for specific compatibility reference). Combine with FifthLight DALI and other energy saving products like sensors, daylighting controls and building management systems to maximize energy savings. ComplianceFixtures and Electrical components certified to UL and CUL standards. Fixtures are damp location listed and IC rated. For Chicago plenum, specify CP in fixture year Neo-Ray Covera - where revolutionary lighting technology meets elegant contemporary design. Our design team broke free from form to develop a beautifully distinguished curved WaveStream panel coupled to a high-performance LED light engine for unmatched appearance and optical performance.

5 Laser-precise AccuAim optics arranged in exacting patterns provide unparalleled brightness control while de-livering optimal distributions tailored to the fixture and application. Eaton s LuxWire technology delivers low-voltage power to the luminaire through the same cables from which it is suspended allowing the luminaire to float beautifully in space without large, unsightly power cables. Luminaire s are available in 2 foot or 4 foot lengths with a vari-ety of custom finishes and mounting options to integrate seamlessly into the space. WaveStream LED SuspendedDirect / Indirect08/28/ 2017 Specifications and dimensions subject to change without additional information on the following E. Colfax AvenueDenver, CO 80011P: 303-393-1522 PS524039EN2 of 4 Neo-Ray - CoveraLUMEN MAINTENANCE @ 25 CFixture LengthLight LevelTM-21 Lumen Maintenance (60,000 hours)Theoretical L70(Hours)2 1, 2, 3, 4, ,0004 1, 2, ,0004 ,0004 ,000 LUMEN PACKAGE DETAIL (3500K) Fixture LengthLight LevelTotal Lumen Output (lms)Power Con-sumption (W)Efficacy (LPW)2 & 5LT Driver, Data from Test Reports P35533, P35535-P35543 FILE NAME: S930 DIP-W335-XX2-U5LT-WCCT: 3500 KLUMENS: 1590 LmsWATTS: WLPW: LPWTEST NUMBER: P35536 FILE NAME: S930 DIP-W335-XX4-U5LT-WCCT: 3500 KLUMENS: 3248 LmsWATTS: WLPW: LPWTEST NUMBER: P35541 ZONAL LUMEN STUDYLUMINANCE DATA (cd / )ZoneLumens% FixtureVertical Angle0 45 90 0 -30 18511.

6 745 2359187315920 -40 2585190 015800 -60 2830195116350 -90 30272196188690 -180 357632322506 All data certified to LM-79 standards in a NAVLAB approved testing facility0 30 60 90 15 45 75 120 150 180 105 135 165 0-deg90-deg266200133670 30 60 90 15 45 75 120 150 180 105 135 165 0-deg90-deg490368245123 ZONAL LUMEN STUDYLUMINANCE DATA (cd / )ZoneLumens% FixtureVertical Angle0 45 90 0 -30 38311. 845 2252187317010 -40 2416193517210 -60 2601203117970 -90 26362265207990 -180 27553328278108/28/ 2017 Specifications and dimensions subject to change without additional information on the following E. Colfax AvenueDenver, CO 80011P: 303-393-1522 of 4 DIMENSIONSNeo-Ray - Covera - Flangeless Sheet RockSR - Sheet RockST - StructurePT - Pierced TileGD - GridUniversal Grid ClipUniversal Grid Hanger Bar4 Individual Fixture2 Individual FixtureMOUNTING - GridPT - Pierced Tile08/28/ 2017 Specifications and dimensions subject to change without additional information on the following E.

7 Colfax AvenueDenver, CO 80011P: 303-393-1522 TABLENeo-Ray - CoveraPS524039EN4 of 4 TECHNICAL NOTES 1) Consult driver table for valid Driver & Light Level configurations. 2) EL7W, EL14W and GTD2 require Voltage selection 1 = 120 VAC or 2 = 277 VAC. Type GD/PT (all lengths) -Battery/GTD internal and pre-wired battery test switch can be tile-mounted or mounted in the cover of a junction box Type SR/SF/ST (4ft length) -Battery/GTD internal and pre-wired, battery test switch is internally mounted. Type SR/SF/ST (2ft length) -Contact factory for availability. Battery pack is external, pre-wired with flexible conduit, remote test switch can be tile-mounted or mounted in the cover of a junction box.

8 GTD2 not available. 3) Voltage selection of 347 VAC only valid with Driver option DD3. 4) Voltage selection of 48 VDC only valid with DLVP Driver option LV1. Not available as standard product on structure mount configuration contact factory if required. 5) Additional light levels available. Please consult factory for specific details. 6) All lengths are nominal. Please refer to submittal drawings for actual sizes. 7) Sensor will be pre-wired and ready for remote tile-mount. Passive infrared occupancy technology. Closed loop, dimming daylight harvesting sensing technology, ~144 sq ft coverage pattern. 8) Price adder and additional lead time may apply please consult online configuration tool and/or price guide. 9) Additional finishes are available that utilize water transfer printing of hydrographic films and automotive grade ) Color and grain of actual finish will vary from unit to unit and may also vary from graphic representation as shown.

9 Please consult an Eaton representitive for paint ) Brushed metal trim edge12) Cable suspension length of 10ft (max length) ships as standard and is cut to length after ) Grid clip cover, Sheet rock cover, and surface mount cover plate ship as standard with white powder coated finish. Contact factory for additional FINISH OPTIONS 8, 9, 10 White Oak (H1) 11 Grey Ash (H2) 11 Dark Walnut (H3) 11 Brown Willow (H4) 11 White Marble (H5)Carbon Fiber (H6)# of Drivers2 Fixture (Light Level & Total Lumens)4 Fixture (Light Level & Total Lumens)Driver TypeL1 = 750 LmsL2 = 1k LmsL3 = LmsL4 = 2k LmsL5 = LmsL1 = LmsL2 = 2k LmsL3 = 3k LmsL4 = 4k LmsL5 = 5k LmsDD1111111112 HCD1111111112 DCD11111111125 LT11111111125 LTHD1111111112 STPN/AN/AN/AN/AN/AN/AN/AN/A11 LUE1111111112 LUL1111111112 LHN/AN/AN/A11N/A1111L5N/AN/AN/A11N/A1111 DD31111111111LV 11111N/A11N/AN/AN/ASR1111111122


Related search queries