DN-7111:L 01/25/2016 Page 1 of 8 NFS2-640(E) Intelligent AddressableFire Alarm SystemIntelligent Fire Alarm Control PanelsDN-7111:L NFS2-640 intelligent Fire Alarm Control Panel is part ofthe ONYX Series of Fire Alarm Controls from stand-alone or network configurations, ONYX Series prod-ucts meet virtually every application NFS2-640 s modular design makes system planning eas-ier. The panel can be configured with just a few devices forsmall building applications, or networked with many devices toprotect a large campus or a high-rise office block. Simply addadditional peripheral equipment to suit the host of other options are available, including single- or multi-channel voice; firefighter s telephone; LED, LCD, or PC-basedgraphic annunciators; networking; advanced detection prod-ucts for challenging environments; wireless fire protection; andmany additional : Unless called out with a version-specific E at the end ofthe part number, NFS2-640 refers to models N

FSP-851 Photo FSI-851 Ion FST-851 Thermal FSA-8000...etc. NBG-12LX FMM-1 IDC FDU-80 LCD2-80 Up to 32 remote displays EIA-485 EIA-485 EIA-232 2048 annunciator/control points Optional 636-point UDACT Dual phone lines to Central Station ACM/AEM-24AT LED Annunciator LDM-32 Custom Graphics ACM-8R Relay Control FCM-1 NAC FRM-1 Relay Contact SLC ...

Tags:

  Sfn2, Fsp 851, Nfs2 640

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of NFS2-640(E) - Honeywell

1 DN-7111:L 01/25/2016 Page 1 of 8 NFS2-640(E) Intelligent AddressableFire Alarm SystemIntelligent Fire Alarm Control PanelsDN-7111:L NFS2-640 intelligent Fire Alarm Control Panel is part ofthe ONYX Series of Fire Alarm Controls from stand-alone or network configurations, ONYX Series prod-ucts meet virtually every application NFS2-640 s modular design makes system planning eas-ier. The panel can be configured with just a few devices forsmall building applications, or networked with many devices toprotect a large campus or a high-rise office block. Simply addadditional peripheral equipment to suit the host of other options are available, including single- or multi-channel voice; firefighter s telephone; LED, LCD, or PC-basedgraphic annunciators; networking; advanced detection prod-ucts for challenging environments; wireless fire protection; andmany additional : Unless called out with a version-specific E at the end ofthe part number, NFS2-640 refers to models NFS2-640 andNFS2-640E; similarly, CPU2-640 refers to models CPU2-640and CPU2-640E.

2 Features Certified for seismic applications when used with the appro-priate seismic mounting kit. Approved for Marine applications when used with listedcompatible equipment. See DN-60688. One, expandable to two, isolated intelligent Signaling LineCircuit (SLC) Style 4, 6 or 7. Wireless fire protection using SWIFT Smart Wireless Inte-grated Fire Technology. See DN-60820. Up to 159 detectors and 159 modules per SLC; 318 devicesper loop/636 per FACP or network node. Detectors can be any mix of ion, photo, thermal, or multi-sensor; wireless detectors are available for use with theFWSG. Modules include addressable pull stations, normally opencontact devices, two-wire smoke detectors, notification, orrelay; wireless modules are available for use with theFWSG.

3 Standard 80-character display, 640-character large display(NCA-2), or display-less (a node on a network). Network options: High-speed network for up to 200 nodes (NFS2-3030,NFS2-640, NFS-320(C), NFS-320 SYS, NCA-2, DVC-EM,ONYXW orks, NFS-3030, NFS-640, and NCA). Standard network for up to 103 nodes (NFS2-3030,NFS2-640, NFS-320(C), NFS-320 SYS, NCA-2, DVC-EM,ONYXW orks, NCS, NFS-3030, NFS-640, NCA, AFP-200,AFP-300/400, AFP-1010, and AM2020). Up to 54 nodeswhen DVC-EM is used in network paging. A switch mode power supply with four Class A/B built-inNotification Appliance Circuits (NAC). Selectable SystemSensor, Wheelock, or Gentex strobe synchronization.

4 Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire Tools online or offline programming utility. Upload/Download, save, store, check, compare, and simulate paneldatabases. Upgrade panel firmware. Autoprogramming and Walk Test reports. Multiple central station communication options: Standard UDACT Internet Internet/GSM 80-character remote annunciators (up to 32). EIA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column printers). History file with 800-event capacity in nonvolatile memory,plus separate 200-event alarm-only file. Alarm Verification selection per point, with automaticcounter.

5 Presignal/Positive Alarm Sequence (PAS). Silence inhibit and Auto Silence timer options. March time/temporal/California two-stage coding/strobesynchronization. Field-programmable on panel or on PC, with VeriFire Toolsprogram check, compare, simulate. Full QWERTY keypad. Battery charger supports 18 200 AH batteries. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitormodules. Automatic time control functions, with holiday exceptions. Surface Mount Technology (SMT) electronics. Extensive, built-in transient protection. Powerful Boolean logic equations. Support for SCS Series smoke control system in 2 of 8 DN-7111:L 01/25/2016 NCA-2 AS PRIMARY DISPLAY Backlit, 640-character display.

6 Supports SCS Series smoke control system in FSCS modewhen SCS is connected to the NCA-2 used as primarydisplay. Supports DVC digital audio loop. Printer and CRT EIA-232 ports. EIA-485 annunciator and terminal mode ports. Alarm, Trouble, Supervisory, and Security INTELLIGENT FEATURES Polls up to 318 devices in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol ( Patent5,539,389). Manual sensitivity adjustment up to nine levels. Pre-alarm ONYX intelligent sensing up to nine levels. Day/Night automatic sensitivity adjustment.

7 Sensitivity windows: Ion to obscuration. Photo to obscuration. Laser (VIEW ) to obscuration. Acclimate Plus to obscuration. IntelliQuad to obscuration. IntelliQuad PLUS to obscuration Drift compensation ( Patent 5,764,142). Degraded mode in the unlikely event that the CPU2-640microprocessor fails, FlashScan detectors revert todegraded operation and can activate the CPU2-640 NACcircuits and alarm relay. Each of the four built-in panelcircuits includes a Disable/Enable switch for this feature. Multi-detector algorithm involves nearby detectors in alarmdecision ( Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant).

8 Maintenance alert (two levels). Self-optimizing (VERY INTELLIGENT EARLY WARNING)SMOKE DETECTION TECHNOLOGY Advanced ONYX intelligent sensing algorithms differentiatebetween smoke and non-smoke signals ( Patent5,831,524). Addressable operation pinpoints the fire location. Early warning performance comparable to the best aspira-tion systems at a fraction of the lifetime ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels withoutoperator intervention or programming. Sensitivity increaseswith heat. Microprocessor-based technology; combination photo andthermal technology. Low-temperature warning signal at 40 F 5 F ( C C).

9 FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO,and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm Intelligent Loop 1 DEVICESFSC-851 IntelliQuad FAPT-851 Acclimate PLUS FSL-751 FlashScan VIEW FSP-851 PhotoFSI-851 IonFST-851 to 32 remote displaysEIA-485 EIA-485 EIA-2322048 annunciator/control pointsOptional 636-point UDACTDual phone lines to Central StationACM/AEM-24AT LED AnnunciatorLDM-32 Custom GraphicsACM-8R Relay Control FCM-1 NAC FRM-1 Relay ContactSLC Intelligent Loop 2 KDM-R2 display ORNCA-2 ORwith no displayPRN Series PrinterNFS2-640 C cabinet size shownFWSG XP6/10 I/O ModulesDN-7111.

10 L 01/25/2016 Page 3 of 8 INTELLIGENT FAAST DETECTORS FSA-5000, FSA-8000,AND FSA-20000 Connects directly to the SLC loop of compatible ONYX series panels. Provides five event thresholds that can be individually pro-grammed with descriptive labels for control-by-event pro-gramming; uses five detector addresses. Uses patented particle separator and field-replaceable filterto remove contaminants. Advanced algorithms reject common nuisance conditions FSA-5000 covers 5,000 square feet through one pipe. FSA-8000 covers 8,000 square feet through one pipe. FSA-20000 covers 28,800 square feet through one to INTELLIQUAD PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR Detects all four major elements of a fire.